EP Relays

Coil data

  • Operating characteristics such as "Operate voltage" and "Release voltage" are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ±5% of rated coil voltage.
  • "Initial" means the condition of products at the time of delivery.
Type Rated coil
voltage
Operate
voltage *
(at 20°C)
Release
voltage *
(at 20°C)
Rated operating
current
(±10%, at 20°C)
Coil resistance
(±10%, at 20°C)
Rated operating
power
Max.
allowable
voltage
20 A 12 V DC Max. 75% V of
Rated coil
voltage
(Initial)
Min. 4.17% V of
Rated coil
voltage
(Initial)
327 mA 36.7 Ω 3.9 W 133% V of
rated coil
voltage
24 V DC 163 mA 146.8 Ω
80 A 12 V DC Min. 8.3% V of
Rated coil
voltage
(Initial)
353 mA 34 Ω 4.2 W
24 V DC 176 mA 136 Ω

* square, pulse driver

Note) When using a DC power supply, use one that provides a current capacity leeway of at least 150% of the rated operating current.

Return to top

Specifications

Item Specifications
20 A type 80 A type
Contact
data
Contact arrangement 1 Form A
Contact material Copper alloy Tungsten type
and Copper alloy
Contact rating
(resistive)
20 A 400 V DC 80 A 400 V DC
Max. switching power
(resistive)
20,000 W 80,000 W
Max. switching voltage 1,000 V DC
Max. cut-off current - 800 A 300 V DC
(1 cycle) *3
Overload cut-off 60 A 400 V DC (Min. 50 cycles) *3 120 A 400 V DC (Min. 50 cycles) *3
Reverse cut-off -20 A 200 V DC (Min. 100 cycles) *3 -80 A 200 V DC (Min. 1,000 cycles) *3
Max. switching current 20 A DC continuity (3 mm2 Wire)
40 A DC 10 min (3 mm2 Wire)
60 A DC 1 min (3 mm2 Wire)
80 A DC continuity (15 mm2 Wire)
120 A DC 15 min (15 mm2 Wire)
180 A DC 2 min (15 mm2 Wire)
Min. switching load
(reference value) *1
1 A 12 V DC 1 A 12 V DC
Contact voltage drop
(Initial)
Max. 0.2 V
(When carrying current is 20 A)
Max. 0.067 V
(When carrying current is 20 A)
Insulation resistance (initial) Min. 100 MΩ
(at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric
strength
(initial)
Between
open contacts
2,500 Vrms for 1 min (detection current: 10 mA)
Between
contact and coil
2,500 Vrms for 1 min (detection current: 10 mA)
Coil holding voltage *4 - 50 to 100% V (at 80°C)
Time
characteristic
(initial)
Operate time Max. 50 ms at rated coil voltage (at 20°C, without bounce)
Release time Max. 30 ms at rated coil voltage (at 20°C, without bounce, without diode)
Shock
resistance
Functional For ON: 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
For OFF: 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Destructive 490 m/s2 (half-sine shock pulse: 6 ms)
Vibration
resistance
Functional 10 to 200 Hz acceleration 43 m/s2 constant (detection time: 10 µs)
Destructive 10 to 200 Hz acceleration 43 m/s2 constant (3 directions, each 4 hours)
Expected life Mechanical life Min. 200 x 103 ope.
Conditions Conditions for usage,
transport and storage *2
Ambient temperature: -40 to +80°C (storage: Max. +85°C),
Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 180 g Approx. 400 g
*1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value.
Refer to Usage, transport and storage conditions in NOTES.
*3Conditions: Varistor used for coil surge absorption.
Note) if a diode is used the life will be lower.
*4Coil holding voltage is the coil voltage after 100 ms from the applied rated coil voltage.

Return to top

Expected electrical life *1

Conditions: Resistive load

Type Switching capacity Number of operations
20 A 10 A 1,000 V DC Min. 103 ope. (switching frequency: 6 times/min) *2
20 A 400 V DC Min. 3 x 103 ope. (switching frequency: 6 times/min) *2
80 A 80 A 400 V DC Min. 103 ope. (switching frequency: 20 times/min) *2
*1Please refer to the reference data for switching and cut-off at 400 V DC and higher.
*2Conditions: Varistor used for coil surge absorption.
Note) if a diode is used the life will be lower.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)