Absolute maximum ratings (Ambient temperature: 25℃)

Item Symbol AQH0213
AQH0223
AQH1213
AQH1223
AQH2213
AQH2223
AQH3213
AQH3223
Remarks
Input LED forward current IF 50 mA  
LED reverse voltage VR 6 V  
Peak forward current IFP 1 A f = 100 Hz,
Duty Ratio = 0.1%
Output Repetitive peak OFF-state voltage VDRM 600 V  
ON-state RMS current IT (RMS) 0.3 A 0.6 A 0.9 A 1.2 A  
Non-repetitive surge current ITSM 3 A 6 A 9 A 12 A In one cycle at 60 Hz
I/O isolation voltage Viso 5,000 Vrms  
Ambient temperature Topr − 30 to + 85℃ Non-icing and
non-condensing
Storage temperature Tstg − 40 to + 125℃ Non-icing and noncondensing
Junction temperature Tj 125°C
*Note: "A" and "AX" at the end of the part numbers have been omitted.

Return to top

Characteristics (Ambient temperature: 25℃)

Item Symbol AQH0213
AQH1213
AQH2213
AQH3213
AQH0223
AQH1223
AQH2223
AQH3223
Remarks
Input LED dropout voltage Typical VF 1.21 V IF = 20 mA
Maximum 1.3 V
LED reverse current Typical IR VR = 6 V
Maximum 10 µA
Output Peak OFF-state current Typical IDRM IF = 0 mA
VDRM = 600 V
Maximum 100 µA
Peak ON-state voltage Typical VTM IF = 10 mA
ITM = Max.
Maximum 2.5 V
Holding current Typical IH  
Maximum 25 mA
Critical rate of rise of OFF-state voltage Minimum dv/dt 200 V/µs VDRM = 600 V ×1/√2
Transfer
characteristics
Trigger LED current Maximum IFT 10 mA VD = 6 V
RL = 100 Ω
Zero-cross voltage Maximum VZC 50 V IF = 10 mA
Turn on time* Maximum TON 100 µs IF = 20 mA
VD = 6 V
RL = 100 Ω
I/O isolation resistance Minimum Riso 50 GΩ 500 V DC

Notes: 1: For type of connection, see "SCHEMATIC AND WIRING DIAGRAMS".
2. "A" and "AX" at the end of the part numbers have been omitted.
*Turn on / Turn off time
Turn on time

Return to top

Recommended operating conditions

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
Input LED current IF 15 25 mA

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)