Individual specifications

Type Resin body type
Model No. FM-252-4(-P) FM-213-4(-P) FM-253-4(-P) FM-214-4(-P) FM-254-8(-P) FM-215-8(-P)
Full scale flow rate
(Note 1)
500 mℓ/min. 1,000 mℓ/min. 5 ℓ/min. 10 ℓ/min. 50 ℓ/min. 100 ℓ/min.
Instant
flow
rate
Display range
(Note 2)
-550 to +550 mℓ/min. -1,100 to +1,100 mℓ/min. -5.5 to +5.5 ℓ/min. -11 to +11 ℓ/min. -55 to +55 ℓ/min. -110 to +110 ℓ/min.
Setting and display resolution 1 mℓ/min. 0.01 ℓ/min. 0.1 ℓ/min.
Integrated
flow
rate
Display range
(Note 2)
±9999999 mℓ ±99999.99 ℓ ±999999.9 ℓ
Setting and display resolution 1 mℓ 0.01 ℓ 0.1 ℓ
Specified integrated value 5 mℓ 10 mℓ 0.05 ℓ 0.1 ℓ 0.5 ℓ 1 ℓ
Port size ø4 ø0.157 push-in ø8 ø0.315 push-in
Weight Net weight: 50 g approx., Gross weight: 115 g approx. Net weight: 70 g approx., Gross weight: 135 g approx.
Type Aluminum body type
Model No. FM-255-AR2(-P) FM-255-AG2-P FM-216-AR2(-P) FM-216-AG2-P
Full scale flow rate
(Note 1)
500 ℓ/min. 1,000 ℓ/min.
Instant
flow
rate
Display range
(Note 2)
-550 to +550 ℓ/min. -1,100 to +1,100 ℓ/min.
Setting and display resolution 1 ℓ/min.
Integrated
flow
rate
Display range
(Note 2)
±9999999 ℓ
Setting and display resolution 1 ℓ
Specified integrated value 5 ℓ 10 ℓ
Port size Rc1/2 female thread G1/2 female thread Rc1/2 female thread G1/2 female thread
Weight Net weight: 155 g approx., Gross weight: 220 g approx.

Common specifications

Type NPN output type PNP output type
Model No. FM-2□ FM-2□-P
CE marking directive compliance EMC Directive, RoHS Directive
Rated pressure range -0.09 to +0.7 MPa
Pressure withstandability 1 MPa
Applicable fluid Clean air (Note 3), compressed air (Note 3), nitrogen gas
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P10 % or less
Current consumption Normal mode: 60 mA or less, ECO mode: 40 mA or less
Comparative outputs
(Comparative output 1 /
Comparative output 2)
NPN open-collector transistor
・Maximum sink current: 50 mA or less
・Applied voltage: 26.4 V DC or less
(between comparative output and 0 V)
・Residual voltage: 2.4 V or less (at 50 mA sink current)
PNP open-collector transistor
・Maximum source current: 50 m A or less
・Applied voltage: 26.4 V DC or less
(between comparative output and +V)
・Residual voltage: 2.4 V or less (at 50 mA source current)
  Output modes Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Short-circuit protection Incorporated
Hysteresis Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
Response time 50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Analog voltage output Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Repeatability Within ±1 % F.S.
Accuracy assurance
range (Note 4)
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
External input ON voltage: 0 to +0.4 V
OFF voltage: +5 V to +V, or open
Input time: 80 ms or more
ON voltage: +5 V to +V
OFF voltage: 0 to +0.6 V, or open
Input time: 80 ms or more
Linearity Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
Display 4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Protection IP40 (IEC)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed),
Storage: -10 to +60 ℃ +14 to +140 ℉
Ambient humidity 35 to 90 % RH, Storage: 35 to 90 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
Insulation resistance 10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Temperature characteristics Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Pressure characteristics Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Enclosure earthing Floating (Note 5)
Material Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connecting method Connector
Cable length Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
Accessory CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.

Note 1 : Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
Note 2 : The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
Note 3 : The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
Note 4 : Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
Note 5 : As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)