Notes:
1) | Input (pink) is the job indicator input when No. 4 of the operation mode switch on the emitter is set to the OFF side, and it is the test input (emission halt input) when the switch is set to the ON side. |
---|---|
2) | In order to use the job indicator as a large operation indicator, connect the input (pink) of the emitter to the output (black) of the receiver. |
3) | When the test input (emission halt input) is set, the job indicator does not light up or blink. |
Symbols・・・ | D1: Reverse supply polarity protection diode D2: Reverse current protection diode D3: Reverse output polarity protection diode ZD: Surge absorption zener diode Tr: NPN output transistor E : Job indicator |
---|
Note: | Refer to “PRECAUTIONS FOR PROPER USE” for job indicator operation or test input (emission halt input) operation. |
---|
Notes:
1) | Input (pink) is the job indicator input when No. 4 of the operation mode switch on the emitter is set to the OFF side, and it is the test input (emission halt input) when the switch is set to the ON side. |
---|---|
2) | In order to use the job indicator as a large operation indicator, connect the input (pink) of the emitter to the output (black) of the receiver. |
3) | When the test input (emission halt input) is set, the job indicator does not light up or blink. |
Symbols・・・ | D1: Reverse supply polarity protection diode D2: Reverse current protection diode D3: Reverse output polarity protection diode ZD: Surge absorption zener diode Tr: PNP output transistor E : Job indicator |
---|
Note: | Refer to “PRECAUTIONS FOR PROPER USE” for job indicator operation or test input (emission halt input) operation. |
---|