【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Wire-Saving Systems > Communication Unit for CC-Link IE Field / CC-Link > Order guide
When optical communication is used in a system connected with product models not compatible with optical communication, connect the incompatible units after the SC-GU3-EU.
A maximum of 12 units can be connected if the system is connected with a FX-500 series unit or LS-501.
A maximum of 16 sensor amplifiers can be connected.
|
Designation | Appearance | Model No. | Descritption |
---|---|---|---|
Communication unit for CC-Link IE Field |
SC-GU3-04 | This is a communication unit, which can convert the output signal of a sensor amplifier into communication data for CC-Link IE Field. | |
Communication unit for CC-Link |
SC-GU3-01 | This is a communication unit, which can convert the output signal of a sensor amplifier into communication data for CC-Link. |
Designation | Appearance | Model No. | Descritption |
---|---|---|---|
End unit | SC-GU3-EU | This end unit can change and check the settings of sensor amplifiers that allow optical communication and monitor operation status. | |
Cascading connector unit |
SC-71 | This one-touch connector is used to connect the following devices to SC-GU3-0□: The FX-500/410/310/300 fiber sensor, the LS-500/400 laser sensor, the DPS-400 digital pressure sensor, SC-E1, SC-A01 and SC-A02, etc. |
|
e-CON 1-channel connector input extension unit |
SC-E1 | This extension unit can be connected to commercially available devices (Note) including an NPN output type or DC 2-wire type sensor. Includes power and input signal indicators (for one channel). When using in combination with the SC-GU3 series, use with the SC-71. | |
e-CON 8-channel connector input extension unit |
SC-E81 | This extension unit can be connected to eight NPN output type devices. Includes power and input signal indicators (for eight channels). | |
e-CON 8-channel connector input extension unit |
SC-E82 | This extension unit can be connected to eight NPN output type devices. Includes a power indicator. (Does not include an input signal indicator) | |
Analog voltage input unit |
SC-A01 | This extension unit can be connected to NPN output type devices or analog voltage output type devices. When using in combination with the SC-GU3 series, use with the SC-71. | |
Analog current input unit |
SC-A02 | This extension unit can be connected to NPN output type devices or analog voltage output type devices. When using in combination with the SC-GU3 series, use with the SC-71. | |
End plate | MS-DIN-E | After SC-GU3-0□, a sensor amplifier, an analog input unit or an end unit are connected on a DIN rail, make sure to install the end plates in such a way that they hold the unit in place at both ends. [Two pcs. per set] |
Note: | Conditions of connectable DC 2-wire type input device ・Leak current: 1 mA or less (when the power is OFF), Offset voltage: 3 V or less (when the power is ON) ・Product whose load current range includes 5 to 8 mA |
---|
|
Designation | Appearance | Model No. | Description |
---|---|---|---|
CC-Link IE Field communication unit for digital displacement sensor |
SC-HG1-CEF | This communication unit converts the output data from digital displacement sensors to data that can be communicated via CC-Link IE Field. | |
CC-Link communication unit for digital displacement sensor |
SC-HG1-C | This communication unit converts the output data from digital displacement sensors to data that can be communicated via CC-Link. | |
End plate | MS-DIN-E | After a communication unit and controllers are connected on a DIN rail, make sure to install the end plates in such a way that they hold the unit in place at
both ends. [Two pcs. per set] |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)