Product Number | JTN1AS-PA-F-DC12V |
Part Number | AJT3515 |
Product name | JT-N Relay(Discontinued) |
Features | High switching capacity 1a/1c 30A power relays |
* | “ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market. |
---|
Item | Specifications |
---|---|
Product Number | JTN1AS-PA-F-DC12V |
Part Number | AJT3515 |
Protective construction | Sealed |
Operating function | Single side stable |
Terminal shape | PC board terminal |
Coil insulation class | Class F insulation |
Packing style | Carton |
Standard packing Carton (pieces) |
50 |
Standard packing Case (pieces) |
500 |
Item | Specifications |
---|---|
Rated coil voltage | 12 V DC |
Operate voltage (at20°C) | Max. 75% V of rated coil voltage (Initial) |
Release voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated operating current [±10%] (at 20°C) | 66.6 mA |
Coil resistance [±10%] (at 20°C) | 180 Ω |
Rated operating power | 800 mW |
Max. allowable voltage (at 20°C) | 120% V of rated coil voltage |
Item | Specifications |
---|---|
Contact arrangement | 1 Form A |
Contact shape | Single |
Contact resistance (initial) | Max. 50 mΩ (by voltage drop 6 V DC 1 A) |
Contact material | AgSnO2 type |
Contact rating (resistive load) | 20 A 277 V AC |
Max. switching power (resistive load) | 8,310 VA (30 A 277 V AC) |
Max. switching voltage | 277 V AC |
Max. switching current | 30 A |
Min. switching load (reference value) | 100 mA 5 V DC |
Insulation resistance (initial) | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric strength (initial) : Between open contacts | 1,200 Vrms for 1 min (detection current: 10 mA) |
Dielectric strength (initial) : Between contact and coil | 2,500 Vrms for 1 min (detection current: 10 mA) |
Operate time (initial) (at 20°C) | Max. 20 ms at rated voltage (without bounce) |
Release time (initial) (at 20°C) | Max. 10 ms at rated voltage (without bounce, without diode) |
Shock resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Shock resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 2 mm) |
Mechanical life | Min. 10x106 ope. |
Electrical life | [switching frequency: 20 times/min] Min. 100x103 ope. 20 A 277 V AC (at resistive load) |
Conditions | Ambient temperature: -55 to +85°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 25 g |
Mark on products* |
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)