AUTOMATION
CONTROLS

Search
Discontinued
Products



ER-VS02 | Ultra-compact Ionizer ER-V


Ultra-compact Ionizer ER-V

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


Product Number ER-VS02
Part Number ER-VS02
Product Ultra-compact Ionizer
Details Spot type
Product name Ultra-compact Ionizer ER-V

As of April 19, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number ER-VS02
Part Number ER-VS02
Charge removal time 1 sec. or less (plus or minus1,000 V to plus or minus100 V)
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Ion balance plus or minus10 V or less
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Ozone generation 0.03 ppm or less
(Note) A typical sample applied with a power voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use.
Applicable fluid Air (dried clean air)
(Note) The air is dried (dew point: equivalent of –20 ℃ – 4 ℉) and filtered (mesh-size: equivalent of 0.01 microm 0.0004 mil) air.
Supplied air flow 500 liter/min. (ANR) or less
(Note) The applicable pressure range depends on the nozzle to be used.
Air pressure range 0.05 to 0.7 MPa
(Note) The applicable pressure range depends on the nozzle to be used.
Supply voltage 24 V DC plus or minus10 %
Current consumption 70 mA or less
Discharge method High frequency AC method
Discharge output voltage 2,000 V approx.
Check output(CHECK) NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between check output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
Check output:Output operation ON when a dirt or worn etc. of the discharge needle is detected for 1.5 sec. or more continuously, OFF when operation is normal
(Note) When confirming the check output, carry out discharge for 2 sec. or more.
Check output:Short-circuit protection Incorporated
Error output NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between error output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
Error output:Output operation OFF when abnormal discharge is detected, ON when operation is normal
Error output:Short-circuit protection Incorporated
Discharge halt input (DSC OFF) Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start)
\n(Note: ”DSC” is an abbreviated name of ”DISCHARGE”.)
Reset input (RESET) When abnormal discharge is detected, discharge is halted due to an error. Reset the discharge halt by briefly shorting the
power supply’s 0 V line.
Indicators:Power (POWER) Green LED (lights up when the power is ON)
Indicators:Discharge (DSC) Green LED (lights up when discharging)
\n(Note: ”DSC” is an abbreviated name of ”DISCHARGE”.)
Indicators:Check (CHECK) Orange LED (lights up when the discharge needle is worn or dirty, etc.)
(Note) When confirming the check output, carry out discharge for 2 sec. or more.
Indicators:Error (ERROR) Red LED (lights up when abnormal discharge is detected)
Ambient temperature 0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed)
Ambient humidity 35 to 65 % RH
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Cable Cable with a connector, 0.5 m 1.640 ft long
Material Enclosure: PPS, Cover: Stainless steel, Discharge needle: Tungsten
Weight Net weight: 120 g approx.
Accessories Connector for wiring: 1 set [Manufactured by Molex: Housing (5557-08R), Terminal (5556TL)]

Return to top

Accessories (Option)

Mini line filter
Product Number ER-AF10
Part Number ER-AF10
Product Mini line filter
Product name Mini line filter
no_image
Product Number ER-AF20
Part Number ER-AF20
Product Mini line filter
Product name Mini line filter
Nozzles / Tubes
Product Number ER-AT50
Part Number ER-AT50
Product Conductive tube
Product name Nozzles / Tubes


More



Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)