| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current) | Normally closed | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less(between output and +V) - Residual voltage: 2 V or less (at 100 mA source current) | Normally open | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less(between output and +V) - Residual voltage: 2 V or less (at 100 mA source current) | Normally closed | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current) | Normally open | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less(between output and +V) - Residual voltage: 2 V or less (at 100 mA source current) | Normally open | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current) | Normally open | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current) | Normally open | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current) | Normally open | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 4.0 mm 0.158 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 3.3 mm 0 to 0.130 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current) | Normally closed | DC-12 or DC-13 | 500 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉ | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |
| | 5 mm 0.197 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 4.2 mm 0 to 0.165 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in | 20 % or less of operation distance(with standard sensing object) | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less(between output and +V) - Residual voltage: 2 V or less (at 100 mA source current) | Normally open | DC-12 or DC-13 | 250 Hz | Orange LED(lights up when the output is ON) | -25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※ | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX's IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within plus or minus 8 % of sensing range at +23degrees +73.4degrees Fahrenheit . | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage | Enclosure: PBT Indicator part: Polyester | | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | 20 g approx. | EMC Directive, RoHS Directive |