RN Relays Cautions For Use

1.For general cautions for use, please refer to the "Relays Cautions For Use".

2.Coil operating power

Pure DC current should be applied to the coil. If it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. The wave form of power should be rectangular. To ensure accurate operation, the voltage on both sides of the coil should be ±5% (at 20°C 68°F) of the nominal coil voltage. Also, please note that the pick-up and drop-out voltages (set and reset voltages) will change depending on operation temperature and conditions of use.

3.Coil connection

This relay is polarized relay, the coil voltage must be applied with correct polarity.

4.External magnetic field

Since RN relays are highly sensitive polarized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition.

5.Cleaning

This product is not sealed type, therefore washing is not allowed.

6.Conditions for operation, transport and storage

1) Temperature: –40 to +85°C –40 to +185°F
   (But allowable temperature is from –40 to +60°C –40 to +140°F at our standard packing condition.)

2) Humidity: 5 to 85% R.H. (Avoid freezing and condensation.)

The humidity range varies with the temperature. Use within the range indicated in the graph below.

3) Atmospheric pressure: 86 to 106 kPa

Temperature and humidity range for usage, transport, and storage

4.Condensation

Condensation forms when there is a sudden change in temperature under high temperature and high humidity conditions. Condensation will cause deterioration of the relay insulation.

5.Freezing

Condensation or other moisture may freeze on the relay when the temperature is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags.

6.Low temperature, low humidity environments

The plastic becomes brittle if the relay is exposed to a low temperature, low humidity environment for long periods of time.

7.Storage requirements

Since the relay is sensitive to humidity, it comes in sealed antihumidity packaging. However, when storing, please be careful of the following.

  • 1.Please use promptly once the anti-humidity pack is opened.
  • 2.When storing for a log period after opening the anti-humidity pack, storage in anti-humidity packaging with an antihumidity bag to which silica gel has been added, is recommended.
    *Furthermore, if the relay is solder mounted when it has been subjected to excessive humidity, cracks and leaks can occur. Be sure to mount the relay under the required mounting conditions.

7.Soldering

Please meet the following conditions if this relay is to be automatically soldered.

1) Position of measuring temperature

A: Surface of PC board where relay is mounted.

2) IR (infrared reflow) soldering method

T1 = 150 to 180°C 302 to 356°F
T2 = 230°C 446°F and higher
T3 = 250°C 482°F max.
t1 = 60s to 120s
t2 = within 30s

• Mounting cautions
Rise in relay temperature depends greatly on the component mix on a given PC board and the heating method of the reflow equipment. Therefore, please test beforehand using actual equipment to ensure that the temperature where the relay terminals are soldered and the temperature at the top of the relay case are within the conditions given above.

3) Please meet the following conditions if this relay is to be soldered by hand.

(1) Max. 260°C 500°F (solder temperature), within 10 seconds (soldering time)
(2) Max. 350°C 662°F (solder temperature), within 3 seconds (soldering time)
The effect on the relay depends on the actual PC board used. Please verify the PC board to be used.

8.Tape and reel packing

1.Tape dimensions (General tolerance: ±0.1 ±.004)

2.Dimensions of plastic reel

9.Measuring method (50Ω type)

Connect connectors 1 and 2 respectively to PORT 1 and PORT 2. Perform calibration using the 3.5 mm calibration kit (HP85052B).

No. Product name Contents
1 Agilent
85130-60011
Adapter
2.4mm-3.5mm female
.095inch-.138inch female
2 SUHNER
SUCOFLEX104
Cable
3.5mm-3.5mm male
.138inch-.138inch male

After calibration, connect the D.U.T. board and measure.
However, connectors other than those for measurement should be connected with a 50Ω termination resistor.

D.U.T. board
Dimensions (mm inch)

Surface mount terminal Standard PC board terminal

Material: Glass PTFE (double-sided, through hole PC board)
R-4737 (manufactured by our company)
Board thickness: t = 0.8 mm .031 inch
Copper plating thickness: 18 μm
Connector (SMA type)
Product name: 01K1808-00 (Waka Manufacturing Co., Ltd.)
Insertion loss compensation: The insertion loss of relay itself is given by subtracting the insertion loss of calibration board.

10. Others

1) The switching lifetime is defined under the standard test condition specified in the JIS* C 5442 standard (temperature 15 to 35°C 59 to 95°F, humidity 25 to 75%RH). Check this with the real device as it is affected by coil driving circuit, load type, activation frequency, activation phase, ambient conditions and other factors.
*JIS: Japanese Industrial Standards
Also, be especially careful of loads such as those listed below.

  • When used for AC load-operating and the operating phase is synchronous, rocking and fusing can easily occur due to contact shifting.
  • When high-frequency opening and closing of the relay is performed with a load that causes arcs at the contacts, nitrogen and oxygen in the air is fused by the arc energy and HNO3 is formed. This can corrode metal materials.

Three countermeasures for these are listed here.
(1) Incorporate an arc-extinguishing circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity

2) Use the relay within specifications such as coil rating, contact rating and on/off service life. If used beyond limits, the relay may overheat, generate smoke or catch fire.

3) Be careful not to drop the relay. If accidentally dropped, carefully check its appearance and characteristics before use.

4) Be careful to wire the relay correctly. Otherwise, malfunction, overheat, fire or other trouble may occur.

5) If a relay stays on in a circuit for many months or years at a time without being activated, circuit design should be reviewed so that the relay can remain non-excited. A coil that receives current all the time heats, which degrades insulation earlier than expected. A latching type relay is recommended for such circuits.

6) To ensure accurate operation of the latching type amidst surrounding temperature changes and other factors that might affect the set and reset pulse times, we recommend a coil impress set and reset pulse width of at least 30 ms at the rated operation voltage.

7) The latching type relay is shipped in the reset position. But jolts during transport or impacts during installation can change the reset position. It is, therefore, advisable to build a circuit in which the relay can be initialized (set and reset) just after turning on the power.

8) If silicone materials (e.g., silicone rubbers, silicone oils, silicone coating agents, silicone sealers) are used in the vicinity of the relay, the gas emitted from the silicone may adhere to the contacts of the relay during opening and closing and lead to improper contact. If this is the case, use a material other than silicone.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)