Coil data

  • Operating characteristics such as 'Operate voltage' and 'Release voltage' are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ±5% of rated coil voltage.
  • 'Initial' means the condition of products at the time of delivery.

1.1 coil latching

Rated coil
voltage
Set voltage *
(at 20°C)
Reset voltage *
(at 20°C)
Rated operating
current
(±10%, at 20°C)
Coil resistance
(±10%, at 20°C)
Rated operating
power
Max. allowable
voltage
(at 20°C)
5 V DC Max. 70% V
of rated coil
voltage
(Initial)
Max. 70% V
of rated coil
voltage
(Initial)
300 mA 16.7 Ω 1.5 W 130% V of
rated voltage
12 V DC 125 mA 96 Ω
24 V DC 62.5 mA 384 Ω
*square, pulse drive

2.2 coil latching

Rated coil
voltage
Set voltage *
(at 20°C)
Reset voltage *
(at 20°C)
Rated operating
current
(±10%, at 20°C)
Coil resistance
(±10%, at 20°C)
Rated operating
power
Max. allowable
voltage
(at 20°C)
5 V DC Max. 70% V
of rated coil
voltage
(Initial)
Max. 70% V
of rated coil
voltage
(Initial)
600 mA 8.3 Ω 3 W 130% V of
rated voltage
12 V DC 250 mA 48 Ω
24 V DC 125 mA 192 Ω
*square, pulse drive

Return to top

Specifications

Item Specifications
Contact data Contact arrangement 1 Form A
Contact voltage drop
(initial)
Max. 0.09 V (at 90 A), Max. 0.05 V (at 10 A)
Contact material AgSnO2 type
Contact rating
(resistive)
90 A 250 V AC
Max. switching power
(resistive)
24,840 VA
Max. switching voltage 276 V AC
Max. switching current 90 A (AC)
Min. switching load
(reference value)
*1
100 mA 125 V AC
Insulation resistance (initial) Min. 1,000 MΩ
(at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric
strength
(initial)
Between
open contacts
2,000 Vrms for 1 min (detection current: 10 mA)
Between
contact and coil
4,000 Vrms for 1 min (detection current: 10 mA)
Surge withstand voltage (initial)*2 Between
contact and coil
12,000 V
Time
characteristics
(initial)
Set time Max. 20 ms at rated coil voltage (at 20°C, without bounce)
Reset time Max. 20 ms at rated coil voltage (at 20°C, without bounce)
Shock
resistance
Functional 300 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Destructive 1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration
resistance
Functional 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
Destructive 10 to 55 Hz (at double amplitude of 2 mm)
Expected life Mechanical life Min. 100 x 103 ope. (switching frequency: at 180 times/min)
Conditions Conditions for usage,
transport and storage
*3 *4
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% RH
(Avoid icing and condensation)
Unit weight Approx. 45 g
*1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2Wave is standard shock voltage of ±1.2 x 50 µs according to JEC-212-1981.
*3For ambient temperature, please read “GUIDELINES FOR RELAY USAGE”.
*4Allowable current when ambient temperature over 70 °C is Max. 70 A.

Return to top

Expected electrical life

Conditions: Resistive load, switching frequency at 20 times/min

Type Load* Switching capacity Number of operations
1 Form A Resistive load 90 A 250 V AC Min. 10 x 103 ope.
(switching frequency ON : OFF = 2 s : 4 s)
UC3 Class (IEC62055-31) 90 A 276 V AC
(COSφ = 1 : 5,000 cycles,
COSφ = 0.5 : 5,000 cycles)
Min. 10 x 103 ope.
(switching frequency ON : OFF = 10 s : 20 s)
*Based on IEC62055-31 UC3, inductive load test was conducted after resistive load test, and expressed as total.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)