AUTOMATION
CONTROLS

Search
Discontinued
Products



JV-N Relays

Coil data

  • Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ±5% of rated coil voltage.
  • ‘Initial’ means the condition of products at the time of delivery.
Rated coil voltage Operate voltage*
(at 20°C)
Release voltage*
(at 20°C)
Rated operating
current
(±10%, at 20°C)
Coil resistance
(±10%, at 20°C)
Rated
operating
power
Max. allowable
voltage
(at 20°C)
4.5 V DC Max. 75% V of
rated coil
voltage
(initial)
Min. 5% V of
rated coil
voltage
(initial)
44.4 mA 101 Ω 200 mW 150% V of
rated coil
voltage
6 V DC 33.3 mA 180 Ω
9 V DC 22.2 mA 405 Ω
12 V DC 16.7 mA 720 Ω
18 V DC 11.1 mA 1,620 Ω
24 V DC 8.3 mA 2,880 Ω
48 V DC 4.2 mA 11,520 Ω
100 V DC Max. 60 V DC Min. 4 V DC 6 mA 16,600 Ω 600 mW 110 V DC
*Square, pulse drive

Return to top

Specifications

Item Specifications
Contact data Contact arrangement 1 Form A
Contact resistance
(initial)
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact material AgSnO2 type
Contact rating
(resistive)
16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC
Max. switching power
(resistive)
2,770 VA, 300 W
Max. switching voltage 277 V AC, 110 V DC (0.3 A)
Max. switching current 16 A (AC), 10 A (DC)
Min. switching load
(reference value)*1
100 mA 5 V DC
Insulation resistance (initial) Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric strength
(initial)
Between
open contacts
1,000 Vrms for 1 min (detection current: 10 mA)
Between
contact and coil
2,500 Vrms for 1 min (detection current: 10 mA)
Surge withstand
voltage (initial)*2
Between
contact and coil
4,500 V
Time characteristics (initial) Operate time Max. 12 ms (4.5 to 48 V DC), Max. 8 ms (100 V DC)
(at rated coil voltage, at 20°C, without bounce)
Release time Max. 5 ms
(at rated coil voltage, at 20°C, without bounce, without diode)
Shock resistance Functional 200m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Destructive 1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration resistance Functional 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 μs)
Destructive 10 to 55 Hz (at double amplitude of 2 mm)
Expected life Mechanical life Min. 20 x 106 ope. (at 180 times/min)
Conditions Conditions for usage,
transport and storage *3
Ambient temperature: –40 to +70°C, –40 to +60°C (at 100 V DC)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 8 g
*1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2Wave is standard shock voltage of ±1.2 x 50 µs according to JEC-212-1981
*3For ambient temperature, please read "GUIDELINES FOR RELAY USAGE".

Return to top

Expected electrical life

Conditions: Resistive load, at 20°C, at 20 times/min

Type Switching capacity Number of operations
1 Form A 10 A 125 V AC Min. 100 x 103 ope.
10 A 30 V DC Min. 100 x 103 ope.
10 A 277 V AC Min. 50 x 103 ope.
16 A 125 V AC Min. 30 x 103 ope.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)