Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > /ac/ae/control/relay/safety/index.jsp?c=search">Safety Relays > > Cautions For Use
Pure DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different.
When connecting coils, refer to the wiring diagram to prevent mis-operation or malfunction.
When using automatic soldering, the following conditions are recommended
1) Preheating: 120 ℃ 248 ℉, within 120 sec (PC board solder surface)
2) Soldering: 260 ℃±5 ℃ 500 ℉±41 ℉, within 6 sec
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)