Magnelimit (Discontinued Products)
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
June 30, 2023 |
|
|
Rating/ Performance
Ratings
Load type |
Resistance load |
Lamp load |
Guidance load |
125V AC |
5A |
1.5A |
3A |
250V AC |
5A |
- |
3A |
30V DC |
5A |
- |
1.5A |
Note 1: | Inductive load is a minimum 0.4 (AC) and time duration is maximum 7ms (DC). |
Note 2: | Lamp load has 10 times the inrush current. |
Nore 3: | Minute load ratings: 5mA 6V DC, 1mA 24V DC. |
Switch operating features
Pretravel (P.T.) |
1.8mm 0.071inch max. |
Movement differential (M.D.) |
0.2 to 0.8 mm |
Release position (R.P.) |
4.0mm 0.157inch max. |
Characteristics
Contact |
Material |
Au clud Ag alloy (Cadmium free) |
Electrical capabilities |
Insulation resistance (initial) |
Min. 100Ω (measured at 500V DC insulation resistance) |
Voltage resistance |
Contact distance: 1000V AC/1 min. (initial) Distance between each pin and uncharged metal parts: 2100V AC/1 min. Distance between each pin and earth: 2100V AC/1 min. |
Mechanical capabilites |
Vibration resistance |
10 to 55 Hz, double amplitude of 1.5 mm |
Shock resistance |
294 m/s2 |
Life |
Mechanical life |
Min. 100 thousand times (ON/OFF frequency 60 times/min.) |
Electrical life |
Min. 50 thousand times (resistance load AC 250V 5A) Min. 30 thousand times (lamp load AC 125V 1.5V) ON/OFF frequency 20 times/min. |
Protective capabilities |
IP40 |
Usage conditions |
Ambient temperature |
–20 to +80℃ –4 to 176℉ (but not in a frozen environment.) |
Ambient humidity |
Max. 95% RH |
Tolerable operating frequency |
Mechanical: 60 times/min. Electrical: 20 times/min. |
Sustainability (when using the enclosed metal plate) |
9.8N {1kgf}(Note 2), 29.4N {3kgf}, 49N {5kgf}(Note 1) |
Note 1 : |
5kgf types will be discontinued at the end of September 2019. |
Note 2 : |
1kgf types will be discontinued at the end of September 2021. |
Return to top
Return to top