AUTOMATION
CONTROLS

Search
Discontinued
Products



KC2S/KE2S (Discontinued Products)

Rating/ Performance

1.Main units

Item Specifications
Eco-COUNT METER
(Power-on Counter)
Eco-HOUR METER
(Power-on Hour Meter)
AKC2421/AKC2621 AKE2421/AKE2621
No. of digits 8 digits 6 digits
External power supply Not required (built-in battery)
Counting max. speed 2Hz
(CT through current minimum power-up time: 250ms, ON:OFF =1:1)
-
Time accuracy - ±100ppm (25℃)
Measurement range 0 to 99999999 counts 0 to 99999.9h
Detection sensitivity
(through current)
Counting start: 0.5A to 80A (50/60Hz)*1 Timing start: 0.5A to 80A (50/60Hz)*1
Counting stop: 0.2A (50/60Hz) or less Timing stop: 0.2A (50/60Hz) or less
Reset
input
Min. input
signal width
100ms
Input method
(signal)
• Non voltage input using contacts or open collector connection
• Input impedance, When shorted: Max.10kΩ, When open: Min.750kΩ
• Residual voltage: Max. 0.5V
Display method 7-segment LCD
Breakdown voltage
(initial)
Between live and dead metal parts: 1,000V AC for 1 minute.
Insulation resistance
(initial)
Between live and dead metal parts: Min. 100MΩ (measured at 500 V DC)
Protective
construction
IEC Standard IP66 (only front panel with rubber gasket)
Vibration resistance
(Functional)
10 to 55 Hz: 1 cycle/min., signal amplitude of 0.15mm .006inch
(10 min. on 3 axes)
Vibration resistance
(Destructive)
10 to 55 Hz: 1 cycle/min., signal amplitude of 0.375mm .015inch
(1 hr. on 3 axes)
Shock resistance
(Functional)
Min. 98m 321.522ft/s2 (4 times on 3 axes)
Shock resistance
(Destructive)
Min. 294m 964.567ft/s2 (5 times on 3 axes)
Operating temperature –10 to +50℃ +14 to +122 (without frost or dew)
Storage temperature –25 to +65℃ –13 to +149 (without frost or dew)
Ambient humidity 35 to 85% RH (at 20℃ non-condensing)
Battery life *2 7 years (at 25℃ 77) 10 years (at 25℃ 77)
Mass (weight) Approx. 110g (Dedicated CT included) Approx. 105g (Dedicated CT included)

*1 Maximum cable diameter is 10 mm.
*2 Battery life is calculated based on the above conditions.
This is not a guarantee of actual battery life.
Please use this as a guide for replacing the battery only.
The actual battery life may be shortened, depending on the utilization environment of the main unit.

2.Dedicated CT

Item Specification
Diameter of conductor
to be measured
10 dia. (max.)
Breakdown voltage
(Initial value)
1,000 Vrms AC for 1min: Between core and output connector terminal
Insulation resistance
(Initial value)
Min. 100MΩ: Between core and output terminal (at 500V DC)
Allowable number of
detachments/attachments
Approx. 100 times
Vibration resistance
(Functional)
10 to 55 Hz: 1 cycle/ min single amplitude of 0.15 mm .006 inch (10 min on 3 axes)
Vibration resistance
(Destructive)
10 to 55 Hz: 1 cycle/ min single amplitude of 0.375 mm .015 inch (1 h on 3 axes)
Shock resistance
(Functional)
Min. 98 m 321.522 ft./s2 (4 times on 3 axes)
Shock resistance
(Destructive)
Min. 294 m 964.567 ft./s2 (5 times on 3 axes)
Operating
temperature range
–10℃ to +50℃ +14 to 122 (Without frost or dew)
Storage temperature –20℃ to +60℃ -4 to 140 (Without frost or dew)
Mass (Weight) Approx. 55g 1.94oz (trunk cable included)
Ambient humidity 35 to 80% R.H. (at 20°C non-condensing)

*1 For Eco-COUNT METER and Eco-HOUR METER, this CT is supplied together.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)