KW1M-R Eco-POWER METER

Dimensions

  • Unit: mm in

KW1M-R(AKW1000/AKW1131)

KW1M-R(AKW1000/AKW1131)

Mounting hole dimensions

Mounting hole dimensions

Dedicated current transformers (CT)

Dedicated current transformer (CT) Clamp-on type 5A/50A (AKW4801C)

Dedicated current transformer (CT) Clamp-on type 100A (AKW4802C)

Dedicated current transformer (CT) Clamp-on type 250A (AKW4803C)

Dedicated current transformer (CT) Clamp-on type 400A (AKW4804C)

Dedicated current transformer (CT) Clamp-on type 600A (AKW4808C)

Return to top

Dedicated current transformer (CT) Through type 50A/100A (AKW4506C)

Dedicated current transformer (CT) Through type 250A/400A/600A (AKW4507C/AKW4508C)

Terminal arrangement

(Master unit) AKW1000

Terminal arrangement

Caution for Wiring

<M3.5 Screws>

  • 1.Terminal fastening torque should be about 1.0 N・m. In case of using a crimping terminal, use it with insulating sleeve applicable to M3.5 screw.
  • 2.This has no built-in power switch, circuit breaker for power supply part. To protect the device, it is necessary to install power switch and circuit breaker in the power supply circuit.
    And this has no built-in power switch, circuit breaker or fuse for measured voltage input parts.
    Therefore it is necessary to install them in the circuit near this unit.
  • 3.We recommend a wire with the cross section of 0.75 to 1.25mm2 for power supply line and measured voltage input line.

  • 4.Shape of the terminal cover

<M3 Screws>

  • 1.Terminal fastening torque should be about 0.5 to 0.6 N・m. In case of using a crimping terminal, use it with insulating sleeve applicable to M3 screw.

  • 2.Shape of the terminal cover

Wiring diagrams

AKW1131

When measuring load with rated input voltage (100 to 200 V AC system and 400 V AC system)

Single-phase two-wire system
*One dedicated current transformers (CT) is required.

Single-phase three-wire system / Three-phase three-wire system
* Two dedicated current transformers (CT) are required.

Notes: 1) Do not wire to (5), (6) terminal. They are connected internal.
Notes:2) Do not wire to (6) terminal. They are connected internal.

Three-phase four-wire system
* Three dedicated current transformers (CT) are required.

When measuring a load with exceed input voltage

Voltage transformer (VT) is needed when you measure a load with over rated input voltage (440V).
Use VT, those secondary rating is 110V.
Grounding the secondary side of VT and CT is not necessary with low-voltage circuit.

Single-phase two-wire system

Single-phase three-wire system / Three-phase three-wire system

Three-phase four-wire system

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)