KW2G-H Eco-POWER METER (Discontinued Products)

Dimensions

  • Unit: mm in

KW2G-H

(Main unit) AKW2020GB

AKW2020GB

(Expansion unit)AKW2110GB/AKW2160GB/AKW2152G/AKW2182G

Dedicated current transformers CT

Dedicated current transformer (CT) Clamp-on type 5A/50A (AKW4801B)

Dedicated current transformer (CT) Clamp-on type 100A (AKW4802B)

Dedicated current transformer (CT) Clamp-on type 250A (AKW4803B)

Dedicated current transformer (CT) Clamp-on type 400A (AKW4804B)

Dedicated current transformer (CT) Clamp-on type 600A (AKW4808B)

Return to top

Dedicated current transformer (CT) Through type 50A/100A (AKW4506B)

Dedicated current transformer (CT) Through type 250A/400A/600A (AKW4507B/AKW4508B)

Return to top


Terminal arrangement

Be sure to wire correctly according to the terminal arrangement and wiring diagrams.
After completing wiring, be sure to attach the terminal cover for safety reasons.

Main unit

Expansion unit (Power measurement and Pulse output : AKW2160GB)

Expansion unit (Pulse input : AKW2152G)

Expansion unit (Pulse input : AKW2152G)

Expansion unit (Analog input : AKW2182G)

Expansion unit (Analog input : AKW2182G)

Wiring diagrams

Single-phase two-wire system
* One dedicated current transformer (CT) is required for one load.

Single-phase three-wire system / Three-phase three-wire system
* Two dedicated current transformers (CT) are required for one load.

Caution for Wiring

  • 1.Terminal fastening torque should be 0.5 to 0.6N・m for M3 screw and should be 0.8 to 1.0N・m for M3.5 screw. In case of using a crimping terminal, use it with insulating sleeve applicable to M3 screw or M3.5 screw.
  • 2.To protect the device, it is necessary to install power switch and circuit breaker in the power supply circuit. And this has no built-in power switch, circuit breaker or fuse for measured voltage input parts. Therefore it is necessary to install them in the circuit near this unit.
  • 3.We recommend a wire with the cross section of 0.75 to 1.25mm2 for power supply line and measured voltage input line.
  • 4.Use with 10m or less of the input line and 100m or less of the output line.
  • 5.Use flame-resistant cable for each wiring.

Discontinued products [Order accepted till December, 2016]

(Main unit) AKW2020G

AKW2020G

(Expansion unit) AKW2110G/AKW2160G

AKW2110G/AKW2160G

Dedicated current transformer (CT) Clamp-on type 5A/50A (AKW4801C)

Dedicated current transformer (CT) Clamp-on type 100A (AKW4802C)

Dedicated current transformer (CT) Clamp-on type 250A (AKW4803C)

Dedicated current transformer (CT) Clamp-on type 400A (AKW4804C)

Dedicated current transformer (CT) Clamp-on type 600A (AKW4808C)

Return to top

Dedicated current transformer (CT) Through type 50A/100A (AKW4506C)

Dedicated current transformer (CT) Through type 250A/400A/600A (AKW4507C/AKW4508C)

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)