KW2G-H Eco-POWER METER (Discontinued Products)
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
September 29, 2023 |
|
|
Dimensions
KW2G-H
(Expansion unit)AKW2110GB/AKW2160GB/AKW2152G/AKW2182G
Dedicated current transformers CT
Dedicated current transformer (CT) Clamp-on type 5A/50A (AKW4801B)
Dedicated current transformer (CT) Clamp-on type 100A (AKW4802B)
Dedicated current transformer (CT) Clamp-on type 250A (AKW4803B)
Dedicated current transformer (CT) Clamp-on type 400A (AKW4804B)
Dedicated current transformer (CT) Clamp-on type 600A (AKW4808B)
Return to top
Dedicated current transformer (CT) Through type 50A/100A (AKW4506B)
Dedicated current transformer (CT) Through type 250A/400A/600A (AKW4507B/AKW4508B)
Return to top
Terminal arrangement
Be sure to wire correctly according to the terminal arrangement and wiring diagrams.
After completing wiring, be sure to attach the terminal cover for safety reasons.
Main unit |
|
|
Expansion unit (Power measurement and Pulse output : AKW2160GB) |
|
|
Expansion unit (Pulse input : AKW2152G) |
|
|
Expansion unit (Analog input : AKW2182G) |
|
|
Wiring diagrams
Single-phase two-wire system
* One dedicated current transformer (CT) is required for one load. |
|
|
Single-phase three-wire system / Three-phase three-wire system
* Two dedicated current transformers (CT) are required for one load. |
|
|
Caution for Wiring
- 1.Terminal fastening torque should be 0.5 to 0.6N・m for M3 screw and should be 0.8 to 1.0N・m for M3.5 screw. In case of using a crimping terminal, use it with insulating sleeve applicable to M3 screw or M3.5 screw.
- 2.To protect the device, it is necessary to install power switch and circuit breaker in the power supply circuit. And this has no built-in power switch, circuit breaker or fuse for measured voltage input parts. Therefore it is necessary to install them in the circuit near this unit.
- 3.We recommend a wire with the cross section of 0.75 to 1.25mm2 for power supply line and measured voltage input line.
- 4.Use with 10m or less of the input line and 100m or less of the output line.
- 5.Use flame-resistant cable for each wiring.
Discontinued products [Order accepted till December, 2016]
(Main unit) AKW2020G |
|
|
(Expansion unit) AKW2110G/AKW2160G |
|
|
Dedicated current transformer (CT) Clamp-on type 5A/50A (AKW4801C)
Dedicated current transformer (CT) Clamp-on type 100A (AKW4802C)
Dedicated current transformer (CT) Clamp-on type 250A (AKW4803C)
Dedicated current transformer (CT) Clamp-on type 400A (AKW4804C)
Dedicated current transformer (CT) Clamp-on type 600A (AKW4808C)
Return to top
Dedicated current transformer (CT) Through type 50A/100A (AKW4506C)
Dedicated current transformer (CT) Through type 250A/400A/600A (AKW4507C/AKW4508C)