Contact-Type Digital Displacement Sensor HG-S
I/O Circuit and Wiring diagrams
NPN output type
HG-SC101 / Master unit |
 |
|
HG-SC111 / Slave unit |
 |
|
HG-SC112 / Slave unit |
 |
|
*1
Non-voltage contact or NPN open collector transistor |
 |
0 to +1.2 V DC: Effective
+8 V to +V DC or open: Ineffective |
Note: Use shielded wire for the analog output.
PNP output type
HG-SC101-P / Master unit |
 |
|
HG-SC111-P / Slave unit |
 |
|
HG-SC112-P / Slave unit |
 |
|
*1
Non-voltage contact or PNP open collector transistor |
 |
+4 V to +V DC: Effective
0 to +0.6 V DC or open: Ineffective |
Note: Use shielded wire for the analog output.