AUTOMATION
CONTROLS

Search
Discontinued
Products



Thru-beam Type Digital Displacement Sensor HG-T

Specifications

Sensor heads

Type Measurement width 10 mm 0.394 in / Standard type Measurement width 10 mm 0.394 in / Slim type
Model No. HG-T1010 HG-T1110
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA regulations
Compatible controller HG-TC101 (-P), HG-TC111 (-P), HG-TC113
Position detection method CMOS-based
Installation distance 0 to 500 mm 0 to 19.685 in
Measurement width 10 mm 0.394 in
Light source Red semiconductor laser: Class 1 [IEC / EN / JIS / GB / KS / FDA (Note 2)]
Maximum output: 0.3 mW, Peak emission wavelength: 655 nm
Repeatability (Note 3) 1 μm 0.039 mil (Installation distance: 20 mm 0.787 in)
2.5 μm 0.098 mil (Installation distance: 100 mm 3.937 in)
5 μm 0.197 mil (Installation distance: 500 mm 19.685 in)
Linearity (Note 4) ±0.12 % F.S. (Installation distance: 20 mm 0.787 in)
±0.28 % F.S. (Installation distance: 100 mm 3.937 in)
Minimum sensing object (Note 5) ø0.5 mm ø0.020 in (Installation distance: 500 mm 19.685 in)
Temperature characteristics (Note 6) ±0.03 % F.S./℃
Operation indicator Emitter Laser radiation indicator (Green)
Receiver Beam axis adjustment indicator (Orange / Green),
Judgment output indicator (Orange / Green)
Judgment output indicator (Orange / Green)
Pollution degree 2
Operating altitude 2,000 m 6,561.68 ft or less (Note 7)
Environmental resistance Protection IP67 (IEC) (Excluding connectors)
Ambient temperature -10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 5,000 lx or less at the light-receiving face (Note 8)
Insulation resistance 20 MΩ or higher, using 250 V DC megger (between all terminals and case)
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration in X, Y and Z directions three times each
Grounding method Capacitor grounding
Material Case: Die-cast aluminum, Light emitting and light receiving surfaces: Glass
Cable 0.2 m 0.656 ft 4-core shielded cable with round connectors
Net weight Emitter: 30 g approx., Receiver: 30 g approx. Emitter: 30 g approx., Receiver: 25 g approx.

Notes:

1) Specification values are based on the digital measurement values obtained by the sensor head and controller HG-TC□. Where measurement conditions have not been specified precisely, the conditions used were as follows: ambient temperature = +20 ℃ +68 ℉, controller’s average count setting 16 times, measurement target = nontransparent knife edge, installation distance = 100 mm 3.937 in, positional condition of measurement target = Half shading at the middle position of installation distance.
2) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
3) This is the P-P value of digital measurement value with half shading at the middle position of the installation distance.
4) Indicates an error with the ideal straight line of digital measured values.
5) When the light is blocked at the center position of 500 mm 19.685 in installation distance.
6) When the light is half-blocked at the center position of 100 mm 3.937 in installation distance.
7) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
8) When the sampling cycle of the controller is set to "standard sampling".

Controller

Type Master unit Slave unit
High performance type High performance type Wire-saving type
Model No. NPN output HG-TC101 HG-TC111 HG-TC113
PNP output HG-TC101-P HG-TC111-P
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Compatible sensor head HG-T1010、HG-T1110
Number of connectable units Up to 15 slave units can be connected to a master unit. (Note 2)
Supply voltage 24 V DC ±10 %, including ripple 0.5 V (P-P)
Current consumption (Note 3) 100 mA or less (when sensor head is connected)
Analog outputs
(Switching type)
(Note 4)
Analog voltage
output
• Voltage output range: 1 to 5 V/F.S. (default value)
• Linearity: ±0.05 % F.S.
• Output when alarm occurs: 5.2 V
• Output impedance: 100 Ω max.
-
Analog current
output
• Current output range: 4 to 20 mA/F.S. (default value)
• Linearity: ±0.25 % F.S.
• Output when alarm occurs: 0 mA
• Load impedance: 250 Ω max.
Control outputs
(Output 1, Output 2, Output 3)
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 50 mA (Note 5)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 50 mA sink current)
• Leakage current: 0.1 mA or less

<PNP output type>
PNP open-collector transistor
• Maximum source current: 50 mA (Note 5)
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less (at 50 mA source current)
• Leakage current: 0.1 mA or less
-
  Short-circuit protection Incorporated (automatic reset type)
Judgment output N.O. / N.C. switching type
Alarm output Open when alarm occurs
External output switching Output 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2. -
External inputs
(Input 1, Input 2, Input 3)
<NPN output type>
Non-contact input or NPN open-collector transistor
• Input conditions
Invalid: +8 V to +V DC or open
Valid: 0 to +1.2 V DC
• Input impedance: 10 kΩ approx.

<PNP output type>
Non-contact input or PNP open-collector transistor
• Input conditions
Invalid: 0 to +0.6 V DC or open
Valid: +4 V to +V DC
• Input impedance: 10 kΩ approx.
-
  Input time • Trigger input: 2 ms or more (ON)
• Laser emission stop input, preset input, reset input, bank input A/B(Note 6): 20 ms or more (ON)
External input switching Input 1, Input 2, and Input 3 can be switched to “Preset / Reset / Trigger”, “Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)”, or “Laser emission stop”. -
Sampling cycle 1 ms (standard sampling) / 0.5 ms (high-speed sampling)
Average count (response time)
(Note 6)
1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type
Display resolution 1 μm 0.039 mil
Display range -199.999 to 199.999 mm -7.874 to 7.874 in
Interference prevention function Incorporated (Note 7) -
Pollution degree 2
Operating altitude 2,000 m 6561.68 ft or less (Note 8)
Environmental resistance Protection IP40(IEC)
Ambient temperature -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed) (Note 5), Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one minute between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Shock resistance 98m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Material Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Cable 0.2 mm2 2-core (brown and blue lead wires) /
0.15 mm2 7-core composite cable, 2 m 6.562 ft long
0.15 mm2 7-core composite cable, 2 m 6.562 ft long -
Net weight 140 g approx. 140 g approx. 60 g approx.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage +24 V DC, ambient temperature +20 ℃ +68 ℉.
2) When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
3) Current consumption does not include analog current output.
4) Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
5) When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.
Number of connected slave units Maximum sink current and source
current of control output
Ambient temperature
  When communication unit is connected
1 to 7 units 1 to 6 units 20 mA -10 to +45 ℃ +14 to +113 ℉
8 to 15 units 7 to 14 units 10 mA
6) Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
7) This function operates for each set of 4 connected controllers.
Interference prevention function
8) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.

HG-T series' self-monitoring function

Status Response parameter Measures Controller HG-TC□
Error code
(Note 1)
Measurement alarm
(Note 1)
Notification Sensor head unconnected Status check E200
Connected sensor head incompatible Status check E230
Connected unit count check error Status check E160
(For master units only)
NPN / PNP output type mixture error Status check E100
(For master units only)
Calculated unlit count error Status check E110
(For master units only)
Copy executionerror (Slave unit problem) Status check E170
(For master units only)
Detection capability limit (obtained edge information) (Note 2) Sensing object check Measurement alarm 1
The amount of entering light is too much due to the influences of ambient light, etc. (Note 2) Status check Measurement alarm 1
The amount of entering light decreases due to stain on the detection surface, beam axis misalignment, etc. Sensing object check Measurement alarm 2
The specified measurement direction differs from the insertion direction of the detected object. Status check / Sensing object check Measurement alarm 2
Caution Controller cumulative run time exceeded (87,600 hours) Controller replacement
Sensor head cumulative run time exceeded (87,600 hours) Sensor head replacement
Controller memory saving count exceeded (1,000,000 times) Controller replacement
Sensor head memory saving count exceeded (for receivers only, 1,000,000 times) Sensor head replacement
Fault Controller memory function damaged Controller replacement E600
E610
E620
Sensor head memory function damaged Sensor head replacement E630(For receivers only)
E640(For emitters only)
Output section short-circuit error Status check / Replacement E700
Detection circuit damaged Sensor head replacement E240
System error Controller replacement E900
E910
E911
E912
E920

Notes:

1) Error codes and alarms are displayed on HG-TC□ controllers.
2) If "Alarm condition selection (ALM.CND)" is set to "Hold last value (HOLD)", Measurement alarm 1 is not notified.

Communication units for digital displacement sensors

Designation USB communication unit
Model No. SC-HG1-USB
Regulatory compliance CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Compatible controllers HG-TC□
Maximum number of
connectable controllers
Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑USB unit
Supply voltage (Note 2) 24 V DC ±10 %, Ripple (P-P) 10 % or less
(Within specified power supply voltage range)
Current consumption 50 mA or less
Communication method USB 2.0 Full Speed (Note 3)
Communication protocol Our dedicated protocol
USB port USB Mini-B (1 port) (Note 4)
Pollution degree 2
Operating altitude 2,000 m 6561.680 ft or less (Note 5)
Environmental
resistance
Protection IP40 (IEC)
Ambient
temperature
-10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage
withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation
resistance
20 MΩ or more, with 250 V DC megger
Vibration
resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Material Enclosure: Polycarbonate
Weight Net weight: 35 g approx., Gross weight: 95 g approx

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Power is supplied from a connected controller / master unit.
3) Dependent on PC environment.
4) USB 2.0 (Mini-B) cable for the connection of a PC is not provided with the product.
Please purchase a USB 2.0 (Mini-B) cable.
5) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.

Please check each product page for other communication units.
>>CC-Link IE Field / CC-Link Communication Unit
>>Communication Unit for Digital Displacement Sensors SC-HG1

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)