Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Measurement Sensors > Measurement Sensors > Ultra High-speed・High-precision Laser Displacement Sensor HL-C2 > Cautions For Use
Discontinuation plan
|
|
・ | This website is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. |
---|
HL-C201AE(-MK) / HL-C201AE-SP2(M) / HL-C201AE-SP3(M) |
||
This product is classified as a Class 1 Laser Product in IEC / JIS standards. Do not look at the laser beam through optical devices such as a lens. |
||
HL-C203BE(-MK) / HL-C205BE(-MK) / HL-C208BE(-MK) / HL-C211BE(-MK) / HL-C235BE(-MK) |
||
This product is classified as a Class 2 Laser Product in IEC / JIS standards. Do not look at the laser beam directly or through optical devices such as a lens. |
||
HL-C205CE(-MK) / HL-C208CE(-MK) / HL-C211CE(-MK) / HL-C235CE(-MK) / HL-C235CE-W(-MK) |
||
This product is classified as a Class 3R Laser Product in IEC / JIS standards. Never directly look at or touch the laser beam or its reflection. |
* This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
This product complies with CE Marking when used together with a controller and programmable display unit that are in compliance with CE Marking. Likewise, the product complies with UKCA Marking when used together with a controller and programmable display unit that are in compliance with UKCA Marking.
|
Exports of models with a minimum resolution of under 0.25 μm 0.010 mil fall under Japanese Export Control,
which is defined by “Foreign Exchange and Foreign Trade Act”. Therefore, anyone who wishes to export or transfer these products outside of Japan is required to obtain the necessary license from the Ministry of Economy, Trade and Industry of Japan. Also, these products fall under international export control regulations, such as Nuclear Suppliers Group (NSG) guidelines 1.B.3.b.1 and Wassenaar Arrangement (WA) 2.B.6.b.1.a, and are objects of the regulation. Please comply with the export control in each country. Note: These products are introduced to limited countries only. Please contact our office for details. |
Sensor head |
|
Controller |
|
Description | Function | |
---|---|---|
① | POWER indicator |
Lights up in green when electricity is provided to the controller. |
② | ALM1 (Alarm) indicator |
Abnormal condition indicator for OUT1. Lights up in red during dark status (poor light intensity) of OUT1 or the sensor head is in unconnected status. |
③ | ALM2 (Alarm) indicator |
Abnormal condition indicator for OUT2. Lights up in red during dark status (poor light intensity) of OUT2 or the sensor head is in unconnected status. |
④ | LASER A indicator | Lights up in green during the laser radiation of Head A. |
⑤ | LASER B indicator | Lights up in green during the laser radiation of Head B. |
⑥ | Analog output terminal |
Terminal for analog data output. |
⑦ | Laser control terminal |
Stops laser emission in case of short-circuiting. |
⑧ | Remote interlock terminal |
Stops laser emission when its opened. |
⑨ | Ethernet connector |
Equipped on HL-C21C□ models. Used for Ethernet communication with controllers. |
⑩ | USB connector | Used for communication with PC using USB. |
⑪ | Console connection connector |
Used for connecting the mini console. |
⑫ | RS-232C connector |
Equipped on HL-C2C□ models. Used for RS-232C communication with controllers. |
⑬ | I/O terminal | Terminal for various I/O and memory change. |
⑭ | Power terminal | Terminal for power supply to the controller. |
⑮ | Sensor head A connection connector |
Controller recognizes a sensor head which is connected to this connector as “Sensor head A” and starts operation. |
⑯ | Sensor head B connection connector |
Controller recognizes a sensor head which is connected to this connector as “Sensor head B”and starts operation. |
⑰ | DIN rail mounting hook | Used for hooking / removing the sensor heads to / from the 35 mm 1.378 in width DIN rail with one-touch simple operation. |
Note: | In case of connecting one sensor head to the controller, be sure to connect the sensor head to ⑮ the sensor head A connection connector (HEAD A) side. If the sensor head is connected to ⑯ the sensor head B connection connector (HEAD B) side, the measurement cannot be performed. |
---|
(Unit: mm in)
(Unit: mm in)
|
|
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)