AUTOMATION
CONTROLS

Search
Discontinued
Products



Ultra High-speed・High-precision Laser Displacement Sensor HL-C2

Specifications

Sensor heads

Small beam spot type

Type Small beam spot type
Model No. IEC / JIS conformed type HL-C201AE HL-C201AE-SP2 HL-C201AE-SP3 HL-C203BE
FDA conformed type HL-C201FE - - HL-C203FE
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, FDA Regulations(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Setup mode
(Note 3)
Specular reflection Diffuse
reflection
Specular
reflection
Measurement
center distance
10 mm
0.394 in
8 mm
0.315 in
15 mm
0.591 in
30 mm
1.181 in
26.4 mm
1.039 in
Measuring range
(Note 4)
±1 mm
±0.039 in
±0.8 mm
±0.031 in
±1 mm
±0.039 in
±5 mm
±0.197 in
±4.6 mm
±0.181 in
Resolution
[Average number
of samples]
(Note 5,6)
HL-C201AE / HL-C201AE-SP2
/ HL-C201AE-SP3 / HL-C201FE
:
0.25 μm 0.010 mil [256]
• HL-C203BE
/ HL-C203FE:
0.25 μm 0.010 mil [256]
Linearity
(Note 7)
±0.02 % F.S.
(HL-C201FE: ±0.025 % F.S.)
±0.03 % F.S.
Temprerature
characteristics
0.01 % F.S./℃
(HL-C201FE:
0.013 % F.S./℃)
0.02 % F.S./℃ 0.01% F.S./℃
Light source Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Max. output: 0.1 mW Max. output: 0.3 mW Max. output: 1 mW
  IEC / JIS conformed type Class 1 (IEC / JIS) Class 2 (IEC / JIS)
  FDA conformed type Class 1
[FDA (Note 8) /
IEC / JIS]
- - Class II (FDA), Class 2 (IEC
/ JIS)
Beam size
(Note 9)
ø20 μm ø0.787 mil approx. ø30 μm ø1.181 mil approx.
Receiving element Linear image sensor
Indicator Laser
emission
Green LED (lights up during laser emission)
Measuring
range
Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
Protection IP67 (IEC) (excluding the connector)
Ambient temperature 0 to +45 ℃ +32 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face (Note 10)
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions three times each
Cable Cabtyre cable, 0.5 m 1.640 ft long with connector
Cable extension Extension up to total 30 m 98.425 ft is possible, with optional cable.
Material Enclosure, Case cover: Die-cast aluminum, Front cover: Glass
Weight 250 g approx. (including cable)
Accessory Laser warning labels (for applicable standards and regulations): 1 set
Type Small beam spot type
Model No. IEC / JIS conformed type HL-C205BE HL-C205CE HL-C208BE HL-C208CE
FDA conformed type - - - -
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, FDA Regulations(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Setup mode
(Note 3)
Diffuse
reflection
Specular
reflection
Diffuse
reflection
Specular
reflection
Diffuse
reflection
Specular
reflection
Diffuse
reflection
Specular
reflection
Measurement
center distance
50 mm
1.969 in
46 mm
1.811 in
50 mm
1.969 in
46 mm
1.811 in
85 mm
3.346 in
81.4 mm
3.205 in
85 mm
3.346 in
81.4 mm
3.205 in
Measuring range
(Note 4)
±5 mm
±0.197 in
±5 mm
±0.197 in
±20 mm
±0.787 in
±6 mm
±0.236 in
±20 mm
±0.787 in
±6 mm
±0.236 in
Resolution
[Average number
of samples]
(Note 5,6)
HL-C205BE / HL-C205CE:
0.25 μm 0.010 mil [256]
HL-C208BE / HL-C208CE: 0.6 μm 0.024 mil [256], 0.25 μm 0.010 mil [4,096]
Linearity
(Note 7)
±0.03 % F.S. ±0.03 % F.S. ±0.1 % F.S. ±0.03 % F.S. ±0.1 % F.S.
Temprerature
characteristics
0.01% F.S./℃
Light source Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Max. output: 1 mW Max. output: 5 mW Max. output: 1 mW Max. output: 5 mW
  IEC / JIS conformed type Class 2 (IEC / JIS) Class 3R (IEC / JIS) Class 2 (IEC / JIS) Class 3R (IEC / JIS)
  FDA conformed type Class 2
[FDA (Note 8) / IEC / JIS]
Class 3R
[FDA (Note 8) / IEC / JIS]
Class 2
[FDA (Note 8) / IEC / JIS]
Class 3R
[FDA (Note 8) / IEC / JIS]
Beam size
(Note 9)
ø70 μm ø2.756 mil approx. ø100 μm ø3.937 mil approx.
Receiving element Linear image sensor
Indicator Laser
emission
Green LED (lights up during laser emission)
Measuring
range
Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
Protection IP67 (IEC) (excluding the connector)
Ambient temperature 0 to +45 ℃ +32 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face (Note 10)
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions three times each
Cable Cabtyre cable, 0.5 m 1.640 ft long with connector
Cable extension Extension up to total 30 m 98.425 ft is possible, with optional cable.
Material Enclosure, Case cover: Die-cast aluminum, Front cover: Glass
Weight 300 g approx. (including cable)
Accessory Laser warning labels (for applicable standards and regulations): 1 set

Notes:

1) Measuring conditions are as follows unless otherwise specified: connection with controller, supply voltage: 24 V DC, ambient temperature: +20℃ +68 ℉, sampling cycle: 40 μs, average number of samples: 256 times, measurement center distance, measurement object: white ceramic [aluminumvapor deposition surface reflection mirror for HL-C201AE / HL-C201AE-SP2 / HL-C201FE, clear glass for HL-C201AE-SP3], and digital measurement value.
2) For products that comply with FDA regulations, please check the part number in the manual.
3) Use the external ND filter (optional) HL-C2F01 in case the amount of reflected beam is too large on Specular Reflection installation. (Cannot be used with HL-C201□.)
4) Measuring range at sampling periods of 20 μs and 10 μs is as follows.
Model
No.
HL-C201□ HL-C201□-SP2 HL-C201□-SP3 HL-C203□ HL-C205□ HL-C208□
Setup
mode
Specular
reflection
Specular reflection Specular
reflection
Diffuse reflection Specular
reflection
Diffuse reflection Specular
reflection
Diffuse reflection Specular
reflection
Sam
pling
20μs +0.1 to +1.0 mm +0.004 to +0.039 in +0.1 to +0.8 mm +0.004 to +0.031 in +0.1 to +1.0 mm +0.004 to +0.039 in 0 to +5.0 mm 0 to +0.197 in 0 to +4.6 mm 0 to +0.181 in +0.5 to +5.0 mm +0.020 to +0.197 in +0.5 to +5.0 mm +0.020 to +0.197 in 0 to +20 mm 0 to +0.787 in 0 to +6.0 mm 0 to +0.236 in
10μs +0.8 to +1.0mm +0.031 to +0.039 in +0.7 to +0.8mm +0.028 to +0.031 in +0.8 to +1.0mm +0.031 to +0.039 in +3.8 to +5.0mm +0.150 in to +0.197 in +3.6 to +4.6mm +0.142 to 0.181 in +4.7 to +5.0mm +0.185 to +0.197 in +4.6 to +5.0mm +0.181 to +0.197 in +18 to +20mm +0.709 to +0.787 in Measurement not possible
5) The P-P value for the deviation in the digital measurement values at the measurement center distance has been converted for the measurement center distance.
6) Exports of models with a minimum resolution of under 0.25 μm 0.010 mil fall under Japanese Export Control defined by “Foreign Exchange and Foreign Trade Act.” These products are introduced to limited countries only. Please refer to “PRECAUTIONS FOR PROPER USE”.
7) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
8) FDA regulatory compliance is attained following the stipulations of Laser Notice No. 50 (June 24, 2007) of FDA regulations (21 CFR 1040.10 and 1040.11).
9) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 % approx.) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
10) Variance is ±0.03 % F.S. or less (±0.08 % F.S. or less for HL-C235CE-W) depending on the ambient illuminance.

Type Small beam spot type
Model No. IEC / JIS conformed
type
HL-C211BE HL-C211CE
FDA
conformed
type
HL-C211FE HL-C211F5E
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, FDA Regulations(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Setup mode(Note 3) Diffuse
reflection
Specular
reflection
Diffuse
reflection
Specular
reflection
Measurement center distance 110mm 4.331 in 106.7mm 4.201 in 110mm 4.331 in 106.7mm 4.201 in
Measuring range
(Note 4)
±15mm
±0.591 in
±14.5mm
±0.571 in
±15mm
±0.591 in
±14.5mm
±0.571 in
Resolution
[Average number of samples]
(Note 5,6)
HL-C211BE / HL-C211CE / HL-C211FE /
HL-C211F5E
: 0.4 μm 0.016 mil [256],
0.25 μm 0.010 mil [4,096]
Linearity (Note 7) ±0.03% F.S.
Temprerature characteristics 0.01% F.S./℃
Light source Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Max. output: 1 mW Max. output: 5 mW
  IEC / JIS conformed type Class 2 (IEC / JIS) Class 3R (IEC / JIS)
  FDA conformed type Class II (FDA),
Class
Class II (FDA),
Class 2 (IEC / JIS)
Class IIIa (FDA),
Class 3R (IEC / JIS)
Beam size (Note 9) ø80 μm ø3.150 mil approx.
Receiving element Linear image sensor
Indicator Laser emission Green LED (lights up during laser emission)
Measuring range Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
Protection IP67 (IEC) (excluding the connector)
Ambient temperature 0 to +45 ℃ +32 to +113 ℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 lx or less at the light-receiving face(Note 10)
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions three times each
Cable Cabtyre cable, 0.5 m 1.640 ft long with connector
Cable extension Extension up to total 30 m 98.425 ft is possible, with optional cable.
Material Enclosure: Die-cast aluminum, Case cover: Die-cast aluminum, Front cover: Glass
Weight 300 g approx. (including cable)
Accessory Laser warning label: 1 set
Type Small beam spot type
Model No. IEC / JIS conformed
type
HL-C235BE HL-C235CE HL-C235CE-W
FDA
conformed
type
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, FDA Regulations(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Setup mode Diffuse
reflectionSpecular
reflection
Specular
reflection
Diffuse
reflection
Specular
reflection
Diffuse
reflection
Measurement center distance 350 mm
13.780 in
348 mm
13.701 in
350 mm
13.780 in
348 mm
13.701 in
350 mm
13.780 in
Measuring range
(Note 4)
±15mm
±0.591 in
±42mm
±1.654 in
±50mm
±1.969 in
±42mm
±1.654 in
±200 mm
±7.874 in
Resolution
[Average number of samples]
(Note 5,6)
2.0 μm 0.079 mil
[256], 0.5 μm 0.020 mil [4,096]
8 μm 0.315 mil [256],
2 μm 0.079 mil [4,096]
Linearity (Note 7) ±0.03 % F.S. ±0.04 % F.S.
(-200 to 0 mm -7.874 to 0 in),
±0.08 % F.S.
(0 to +200 mm 0 to +7.874 in),
(F.S. = ±200 mm ±7.874 in)
Temprerature characteristics 0.01% F.S./℃
Light source Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Max. output: 1 mW Max. output: 5 mW Max. output: 5 mW
  IEC / JIS conformed type Class 2 (IEC / JIS) Class 3R (IEC / JIS) Class 3R (IEC / JIS)
  FDA conformed type Class II (FDA),
Class
Class 3R
[FDA (Note 8) / IEC / JIS]
Beam size (Note 9) ø250 μm ø9.843 mil approx. ø400 μm ø15.748 mil approx.
Receiving element Linear image sensor
Indicator Laser emission Green LED (lights up during laser emission)
Measuring range Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
Protection IP67 (IEC) (excluding the connector)
Ambient temperature 0 to +45 ℃ +32 to +113 ℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 lx or less at the light-receiving face
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions three times each
Cable Cabtyre cable, 0.5 m 1.640 ft long with connector
Cable extension Extension up to total 30 m 98.425 ft is possible, with optional cable.
Material Enclosure: Die-cast aluminum, Case cover: Die-cast aluminum, Front cover: Glass
Weight 450 g approx. (including cable) 300 g approx. (including cable)
Accessory Laser warning label: 1 set

Notes:

1) Measuring conditions are as follows unless otherwise specified: connection with controller, supply voltage: 24 V DC, ambient temperature: +20℃ +68 ℉, sampling cycle: 40 μs, average number of samples: 256 times, measurement center distance, measurement object: white ceramic, and digital measurement value.
2) For products that comply with FDA regulations, please check the part number in the manual.
3) Use the external ND filter (optional) HL-C2F01 in case the amount of reflected beam is too large on Specular Reflection installation. (Cannot be used with HL-C201□.)
4) Measuring range at sampling periods of 20 μs and 10 μs is as follows.
Model No. HL-C211□ HL-C235□ HL-C235CE-W
Setup mode Diffuse reflection Specular reflection Diffuse reflection Diffuse reflection Diffuse reflection
Sampling 20 μs +0.5 to +15.0 mm
+0.020 to +0591 in
+0.5 to +14.5 mm
+0.020 to +0.571 in
0 to +50 mm
0 to +1.969 in
0 to +42 mm
0 to +1.654 in
-70 to +200 mm
-2.756 to +7.874 in
10 μs +12.5 to +15.0 mm
+0.492 to +0.591 in
+12.5 to +14.5 mm
+0.492 to +0.571 in
+36 to +50 mm
+1.417 to +1.969 in
+36 to +42 mm
+1.417 to +1.654 in
+100 to +200 mm
+3.937 to +7.874 in
5) The P-P value for the deviation in the digital measurement values at the measurement center distance has been converted for the measurement center distance.
6) Exports of models with a minimum resolution of under 0.25 μm 0.010 mil fall under Japanese Export Control defined by “Foreign Exchange and Foreign Trade Act.” These products are introduced to limited countries only. Please refer to “PRECAUTIONS FOR PROPER USE”.
7) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
8) FDA regulatory compliance is attained following the stipulations of Laser Notice No. 50 (June 24, 2007) of FDA regulations (21 CFR 1040.10 and 1040.11).
9) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 % approx.) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
10) Variance is ±0.03 % F.S. or less (±0.08 % F.S. or less for HL-C235CE-W) depending on the ambient illuminance.

Linear beam spot type

Type Linear beam spot type
Model No. IEC / JIS conformed type HL-C201AE-MK HL-C201AE-SP2M HL-C201AE-SP3M HL-C203BE-MK
FDA conformed type HL-C201FE-MK - - HL-C203FE-MK
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, FDA Regulations(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Setup mode
(Note 3)
Specular reflection Diffuse
reflection
Specular reflection
Measurement
center distance
10 mm
0.394 in
8 mm
0.315 in
15 mm
0.591 in
30 mm
1.181 in
26.4 mm
1.039 in
Measuring range
(Note 4)
±1 mm
±0.039 in
±0.8 mm
±0.031 in
±1 mm
±0.039 in
±5 mm
±0.197 in
±5 mm
±0.181 in
Resolution
[Average number
of samples]
(Note 5,6)
HL-C201AE-MK / HL-C201AE-SP2M
/ HL-C201AE-SP3M / HL-C201FE-MK
:
0.25 μm 0.010 mil [256]
HL-C203BE-MK
/ HL-C203FE-MK
:
0.25 μm 0.010 mil [256]
Linearity
(Note 7)
±0.02 % F.S.
(HL-201FE-MK: ±0.025 % F.S.).
±0.03 % F.S
Temprerature
characteristics
0.01% F.S./℃ 0.02 % F.S./℃ 0.01 % F.S./℃
Light source Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Max. output: 1 mW Max. output: 0.3 mW Max. output: 1 mW
Class 1
[FDA (Note 8) / IEC / JIS]
- - Class II (FDA),
Class 2 (IEC / JIS)
Beam size
(Note 9)
20 × 700 μm
0.787 × 27.559 mil mil approx.
30 × 1,400 μm
1.181 × 55.118 mil mil approx.
30 × 1,200 μm
1.181 × 47.244 mil mil approx.
Receiving element Linear image sensor
Indicator Laser
emission
Green LED (lights up during laser emission)
Measuring
range
Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
Protection IP67 (IEC) (excluding the connector)
Ambient temperature 0 to +45 ℃ +32 to +113 ℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx at or less the light-receiving face (Note 9)
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directionsthree times each
Cable Cabtyre cable, 0.5 m 1.640 ft long with connector
Cable extension Extension up to total 30 m 98.425 ft is possible, with optional cable.
Material Enclosure, Case cover: Die-cast aluminum, Front cover: Glass
Weight 250 g approx. (including cable)
Accessory Laser warning labels (for applicable standards and regulations): 1 set
Type Linear beam spot type
Model No. HL-C205BE-MK HL-C205CE-MK HL-C208BE-MK HL-C208CE-MK
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, FDA Regulations(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Setup mode
(Note 3)
Diffuse
reflection
Specular
reflection
Diffuse
reflection
Specular
reflection
Diffuse
reflection
Specular
reflection
Diffuse
reflection
Specular
reflection
Measurement
center distance
50 mm
1.969 in
46 mm
1.811 in
50 mm
1.969 in
46 mm
1.811 in
85 mm
3.346 in
81.4 mm
3.205 in
85 mm
3.346 in
81.4 mm
3.205 in
Measuring range
(Note 4)
±5 mm
±0.197 in
±5 mm
±0.197 in
±5 mm
±0.197 in
±5 mm
±0.197 in
±20 mm
±0.787 in
±6 mm
±0.236 in
±20 mm
±0.787 in
±6 mm
±0.236 in
Resolution
[Average number
of samples]
(Note 5,6)
HL-C205BE-MK
/ HL-C205CE-MK
:
0.25 μm 0.010 mil [256]
HL-C208BE-MK
/ HL-C208CE-MK
:
0.6 μm 0.024 mil [256],
0.25 μm 0.010 mil [4,096]
Linearity
(Note 7)
±0.03 % F.S. ±0.03 % F.S. ±0.1 % F.S. ±0.03 % F.S. ±0.1 % F.S.
Temprerature
characteristics
0.01% F.S./℃
Light source Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Max. output: 1 mW Max. output: 5 mW Max. output: 1 mW Max. output: 5 mW
Class 2 (IEC / JIS) Class 3R (IEC / JIS / GB), Class IIIa (FDA) Class 2 (IEC / JIS) Class 3R (IEC / JIS / GB), Class IIIa (FDA)
Beam size
(Note 9)
70 × 1,000 μm
2.756 × 39.370 mil approx.
100 × 1,200 μm
3.937 × 47.244 mil approx.
Receiving element Linear image sensor
Indicator Laser
emission
Green LED (lights up during laser emission)
Measuring
range
Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC) (excluding the connector)
Ambient temperature 0 to +45 ℃ +32 to +113 ℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx at or less the light-receiving face (Note 10)
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions three times each
Cable Cabtyre cable, 0.5 m 1.640 ft long with connector
Cable extension Extension up to total 30 m 98.425 ft is possible, with optional cable.
Material Enclosure, Case cover: Die-cast aluminum, Front cover: Glass
Weight 300 g approx. (including cable)
Accessory Laser warning labels (for applicable standards and regulations): 1 set

Notes:

1) Measuring conditions are as follows unless otherwise specified: connection with controller, supply voltage: 24 V DC, ambient temperature: +20℃ +68 ℉, sampling cycle: 40 μs, average number of samples: 256 times, measurement center distance, measurement object: white ceramic [aluminum vapor deposition surface reflection mirror for HL-C201A(E)-MK / HL-C201A(E)-SP2M / HL-C201F(E)-MK, clear glass for HL-C201A(E)-SP3M], and digital measurement value.
2) For products that comply with FDA regulations, please check the part number in the manual.
3) Use the external ND filter (optional) HL-C2F01 in case the amount of reflected beam is too large on Specular Reflection installation. (Cannot be used with HL-C201□.)
4) Measuring range at sampling periods of 20 μs and 10 μs is as follows.
Model No. HL-C201□-MK HL-C201□-SP2M HL-C201□-SP3M
Setup mode Specular
reflection
Specular reflection Specular
reflection
Sampling 20μs +0.1 to +1.0 mm
+0.039 in
+0.1 to +0.8 mm
+0.004 to +0.031 in
+0.1 to +1.0 mm
+0.004 to +0.039 in
10μs +0.8 to +1.0mm
+0.031 to +0.039 in
+0.7 to +0.8mm
+0.028 to +0.031 in
+0.8 to +1.0mm
+0.031 to +0.039 in

Model No. HL-C203□-MK HL-C205□-MK HL-C208□-MK
Setup mode Diffuse reflection Specular reflection Diffuse reflection Specular reflection Diffuse reflection Specular reflection
Sampling 20μs 0 to +5.0 mm
0 to +0.197 in
0 to +4.6 mm
0 to +0.181 in
+0.5 to +5.0 mm
+0.020 to +0.197 in
+0.5 to +5.0 mm
+0.020 to +0.197 in
0 to +20 mm
0 to +0.787 in
0 to +6.0 mm
0 to +0.236 in
10μs +3.8 to +5.0mm
+0.150 in to +0.197 in
+3.6 to +4.6mm
+0.142 to 0.181 in
+4.7 to +5.0mm
+0.185 to +0.197 in
+4.6 to +5.0mm
+0.181 to +0.197 in
+18 to +20mm
+0.709 to +0.787 in
Measurement
not possible
5) The P-P value for the deviation in the digital measurement values at the measurement center distance has been converted for the measurement center distance.
6) Exports of models with a minimum resolution of under 0.25 μm 0.010 mil fall under Japanese Export Control defined by “Foreign Exchange and Foreign Trade Act.” These products are introduced to limited countries only. Please refer to “PRECAUTIONS FOR PROPER USE
7) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
8) FDA regulatory compliance is attained following the stipulations of Laser Notice No. 50 (June 24, 2007) of FDA regulations (21 CFR 1040.10 and 1040.11).
9) This beam diameter is the size at the measurement center distance. These values were defined by using 1/es2 (13.5 % approx.) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
10) Variance is ±0.03 % F.S. or less depending on the ambient illuminance.

Type Linear beam spot type
Model No. IEC / JIS conformed type HL-C211BE-MK HL-C211CE-MK
FDA conformed type HL-C211FE-MK HL-C211F5E-MK
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, FDA Regulations(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Setup mode(Note 3) Diffuse reflection Specular reflection Diffuse reflection Specular reflection
Measurement center distance 110 mm
4.331 in
106.7 mm
4.201 in
110 mm
4.331 in
106.7 mm
4.201 in
Measuring range (Note 4) ±15 mm
±0.591 in
±14.5 mm
±0.571 in
±15 mm
±0.591 in
±14.5 mm
±0.571 in
Resolution
[Average number of samples]
(Note 5,6)
HL-C211BE-MK / HL-C211CE-MK
/ HL-C211FE-MK / HL-C211F5E-MK
:
0.4 μm 0.016 mil [256], 0.25 μm 0.010 mil [4,096]
Linearity
(Note 7)
±0.03% F.S.
Temprerature characteristics 0.01% F.S./℃
Light source Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Max. output: 0.1 mW Max. output: 5 mW
  IEC / JIS conformed type Class 2 (IEC / JIS) Class 3R (IEC / JIS)
  FDA conformed type Class II (FDA),
Class 2 (IEC / JIS)
Class IIIa (FDA),
Class 3R (IEC / JIS)
Beam size (Note 9) 80 × 1,700 μm
3.150 × 66.929 mil approx.
Receiving element Linear image sensor
Indicator Laser emission Green LED (lights up during laser emission)
Measuring range Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
Protection IP67 (IEC) (excluding the connector)
Ambient temperature 0 to +45 ℃ +32 to +113 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 lx or less at the light-receiving face (Note 10)
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions three times each
Cable Cabtyre cable, 0.5 m 1.640 ft long with connector
Cable extension Extension up to total 30 m 98.425 ft is possible, with optional cable.
Material Enclosure: Die-cast aluminum, Case cover: Die-cast aluminum, Front cover: Glass
Weight 300 g approx. (including cable)
Accessory Laser warning labels (for applicable standards and regulations): 1 set

Return to top

Type Linear beam spot type
Model No. IEC / JIS conformed type HL-C235BE-MK HL-C235CE-MK HL-C235CE-WMK
FDA conformed type - - -
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, FDA Regulations(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Setup mode(Note 3) Diffuse reflection Specular reflection Diffuse reflection Specular reflection Diffuse reflection Specular reflection
Measurement center distance 350 mm
13.780 in
348 mm
13.701 in
350 mm
13.780 in
348 mm
13.701 in
350 mm
13.780 in
Measuring range (Note 4) ±50 mm
±1.969 in
±42 mm
±1.654 in
±50 mm
±1.969 in
±42 mm
±1.654 in
±200 mm
±7.874 in
Resolution
[Average number of samples]
(Note 5,6)
2.0 μm 0.079 mil [256], 0.5 μm 0.020 mil [4,096] 8 μm 0.315 mil [256],
2 μm 0.079 mil [4,096]
Linearity
(Note 7)
±0.03% F.S. ±0.04 % F.S.
(-200 to 0 mm -7.874 to 0 in),
±0.08 % F.S.
(0 to +200 mm 0 to +7.874 in),
(F.S. = ±200 mm ±7.874 in)
Temprerature characteristics 0.01% F.S./℃
Light source Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Max. output: 1 mW Max. output: 5 mW
  IEC / JIS conformed type Class 2 (IEC / JIS) Class 3R (IEC / JIS)
  FDA conformed type - Class 3R
[FDA (Note 8) /
IEC / JIS]
Beam size (Note 9) 250 × 3,500 μm
9.843 × 137.795 mil approx.
400 × 6,500 μm
15.748 × 255.905 mil approx.
Receiving element Linear image sensor
Indicator Laser emission Green LED (lights up during laser emission)
Measuring range Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
Protection IP67 (IEC) (excluding the connector)
Ambient temperature 0 to +45 ℃ +32 to +113 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 lx or less at the light-receiving face (Note 10)
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions three times each
Cable Cabtyre cable, 0.5 m 1.640 ft long with connector
Cable extension Extension up to total 30 m 98.425 ft is possible, with optional cable.
Material Enclosure: Die-cast aluminum, Case cover: Die-cast aluminum, Front cover: Glass
Weight 450 g approx. (including cable) 300 g approx. (including cable)
Accessory Laser warning labels (for applicable standards and regulations): 1 set

Notes:

1) Measuring conditions are as follows unless otherwise specified: connection with controller, supply voltage: 24 V DC, ambient temperature: +20℃ +68 ℉, sampling cycle: 40 μs, average number of samples: 256 times, measurement center distance, measurement object: white ceramic, and digital measurement value.
2) For products that comply with FDA regulations, please check the part number in the manual.
3) Use the external ND filter (optional) HL-C2F01 in case the amount of reflected beam is too large on Specular Reflection installation.
4) Measuring range at sampling periods of 20 μs and 10 μs is as follows.
Model No. HL-C211□-MK HL-C235□-MK HL-C235CE-WMK
Setup mode Diffuse reflection Specular reflection Diffuse reflection Specular reflection Diffuse reflection
Sampling 20μs +0.5 to +15.0 mm
+0.020 to +0.591 in
+0.5 to +14.5 mm
+0.020 to +0.571 in
0 to +50 mm
0 to +1.969 in
0 to +42 mm
0 to +1.654 in
-70 to +200 mm
-2.756 to +7.874 in
10μs +12.5 to +15.0 mm
+0.492 to +0.591 in
+12.5 to +14.5 mm
+0.492 to +0.571 in
+36 to +50 mm
+1.417 to +1.969 in
+36 to +42 mm
+1.417 to +1.654 in
+100 to +200 mm
+3.937 to +7.874 in
5) The P-P value for the deviation in the digital measurement values at the measurement center distance has been converted for the measurement center distance.
6) Exports of models with a minimum resolution of under 0.25 μm 0.010 mil fall under Japanese Export Control defined by “Foreign Exchange and Foreign Trade Act.” These products are introduced to limited countries only. Please refer to “PRECAUTIONS FOR PROPER USE
7) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
8) FDA regulatory compliance is attained following the stipulations of Laser Notice No. 50 (June 24, 2007) of FDA regulations (21 CFR 1040.10 and 1040.11).
9) This beam diameter is the size at the measurement center distance. These values were defined by using 1/es2 (13.5 % approx.) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
10) Variance is ±0.03 % F.S. or less (±0.08 % F.S. or less for HL-C235CE-WMK) depending on the ambient illuminance.

Return to top

Controllers

Type RS-232C-compatible Ethernet-compatible
Item
Mode No. NPN output type HL-C2C(E) HL-C21C(E)
PNP output type HL-C2C(E)-P HL-C21C(E)-P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), China RoHS, Korean S-mark(Note 2), Korea’s radio regulations (Radio Wave Act KC)
Connectale sensor head Number of connectable units: Max. 2 units.
Supply voltage 24 V DC ± 10 % including ripple 0.5 V (P-P)
Current consumption 500 mA approx. at 2 sensor heads connected
350 mA approx. at 1 sensor head connected
(100 mA approx. is additionally required when the mini console is connected)
Sampling cycle 10 μs, 20 μs, 40 μs, 100 μs, 200 μs, 400 μs, 1 ms, 2 ms
Analog output Voltage (Note 3) Voltage output scale: -5 to +5 V/F.S (initial value)
Output range during normal status: -10.0 to +10.0 V
Output at abnormal status: -10.8 V or +10.8 V
Resolution: 2 mV, Linearity: ±0.05 % F.S.
Max. 2 mA, output impedance 50 Ω
Response delay time: 1.5 μs/V approx.
Current (Note 4) Current output scale: 4 to 20 mA/F.S (initial value)
Output range during normal status: 2 to 24 mA
Output at abnormal status: 1 mA or 25 mA
Resolution: 3 μA, Linearity ±0.05% F.S.
Load impedance: 250 Ωmax.
Response delay time: 10 μs approx.
Alarm output   <NPN open-collector transistor>
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less [between each output and Common(-)]
・Residual voltage: 1 V or less (at 100 mA sink current)

<PNP open-collector transistor>
・Maximum source current: 100 mA
・Applied voltage: 30 V DC or less (between each output and +V)
・Residual voltage: 1 V or less (at 100 mA source current)
Output operation Opened when the amount of light is insufficient
Short-circuit protection ncorporated
Judgment output
(HI, GO, LO)
  <NPN open-collector transistor>
Laser emission is delayed when connected to Common (-).
Laser emission stops at open
Applied voltage: 30 V DC or less
(Leak current: 0.1 mA or less)

<PNP open-collector transistor>
Laser emission is delayed when connected to IL (+).
Laser emission stops at open
Applied voltage: 30 V DC or less
(Leak current: 0.1 mA or less)
Output operation Opened at output operation
Short-circuit
protection
Incorporated
Strobe output   <NPN output type>
NPN open-collector transistor
••Maximum sink current: 100 mA
••Applied voltage: 30 V DC or less
[between strobe output to Common (–)]
••Residual voltage: 1 V or less (at 100 mA sink current)

<PNP output type>
PNP open-collector transistor
••Maximum source current: 100 mA
••Applied voltage: 30 V DC or less
(between strobe output to +V)
••Residual voltage: 1 V or less (at 100 mA source current)
Output operation Opened at data determination
Short-circuit
protection
Incorporated
Remote interlock input <NPN output type>
Laser emission is delayed when connected to Common (–).
Laser emission stop at open
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)

<PNP output type>
Laser emission is delayed when connected to IL (+).
Laser emission stop at open
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Laser control input <NPN output type>
Laser emission is stopped when connected to Common (–).
Laser is emitted immediately after opened.
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)

<PNP output type>
Laser emission is stopped when connected to external power (+).
Laser is emitted immediately after opened.
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Zero set input <NPN output type>
Zero set is ON when connected with Common (–).
Zero set turns to OFF after continuously connected to Common
(–) for one second.
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)

<PNP output type>
Zero set is ON when connected with external power (+).
Zero set turns to OFF after continuously connected to external
power (+) for one second.
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Timing input <NPN output type>
ON at/during connection to Common (–)
(depending on analysis mode)
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)

<PNP output type>
ON at/during connection to external power (+)
(depending on analysis mode)
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Reset input <NPN output type>
Reset is done when connected to Common (–).
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)

<PNP output type>
Reset is done when connected to external power (+).
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Memory change input <NPN output type>
Memory is specified when connected to Common (–).
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)

<PNP output type>
Memory is specified when connected to external power (+).
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
RS-232C interface Baud rate 9,600, 19,200, 38,400, 115,200 bit/s -
Ethernet interface (Note 5) - IEEE802.3u, 10BASE-T/100BASE-TX RJ45
Compatible protocols: iQSS-compatible proprietary protocol,
MC protocol, MEWTOCOL
USB interface USB 2.0 full speed (USB 1.1 compatible) compliant
Setting / data display GT12 Programmable Display (optional)
Indicator Power Green LED (lights up at power on)
Sensor head A
Laser radiation
Green LED (lights up during or immediately before laser emission of sensor head A)
Sensor head B
Laser radiation
Green LED (lights up during or immediately before laser emission of sensor head B)
Alarm 1 Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Alarm 2 Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
Environmental resistance Ambient temperature 0 to +50℃ +32 to +122℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient humidity 35 to 85 %RH
Vibration resistance 10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in double amplitude in X, Y and Z directions for 30 min. each
Shock resistance 196 m/s2 acceleration (20 G approx.) in X, Y, and Z directions three times each
Material Case: Polycarbonate
Weight 450 g approx.
Accessories USB cable (2 m 6.562 ft long): 1 pc.,
Short bracket: 1 pc.
USB cable (2 m 6.562 ft long): 1 pc., Short bracket: 1 pc.
Ferrite core (E04SR200935A made by Seiwa Electric Mfg. Co.): 3 cores

Notes:
1) HL-C2C(-P) / HL-C21C(-P) are restricted for export in accordance with the “Foreign Exchange and Foreign Trade Law”. These products are introduced to limited countries only. Please refer to “PRECAUTIONS FOR PROPER USE”
2) For products certified with the Korean S-mark, please check the part number in the manual.
3) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
4) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
5) For Ethernet communication settings of HL-C21C(E) (-P), Configurator WD (Ethernet communication setting tool, Ver. 1.62 or later) is required.

Return to top

Compact consoles

Programmable display GT12 can be used as a console. Please refer to the specifications of Programmable Display GT12 for more information.

Discontinued products [Compact consoles]

Type HL-C2DP-EX HL-C2DP-CH HL-C2DP-KR
Power Supplied by controller
Display Display element STN monochrome LCD
Back light White LED
Display range -999.999999 to 999.999999
Language English Chinese Korean
Touch panel Operational force 0.5 N or less
Lifetime 1,000,000 times or more (Note 1)
Environment resistance IP65 (at initial status) (Note 2)
Dust prevention and drip-proof at the front panel (waterproof packing is used at the contact surface to board)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient humidity 20 to 85 %RH, Storage: 10 to 85 %RH
Electrostatic noise resistance 5,000 V or more (panel surface)
Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y, and Z directions for 10 min. each
Shock resistance 98 m/s2 or more acceleration (10G approx.) in X, Y, and Z directions for four times each
Material Case: PPE, Front protective sheet: Polyester
Weight 230 g approx.
Accessory Connector cable for connecting the controller to the console : 1 pc., Mounting bracket: 1 set

Notes:
1) This value indicates the average lifetime of the unit when used under a normal temperature of 25 ℃ +77 ℉.
2) When reinstalling the console, replace the water proof packing. (Part No: AIGT181, 10 packs included)

Discontinued products [Compact consoles]

Type HL-C2DP-EX HL-C2DP-CH HL-C2DP-KR
Power Supplied by controller
Display Display element STN monochrome LCD
Back light White LED
Display range -999.999999 to 999.999999
Language English Chinese Korean
Touch panel Operational force 0.5 N or less
Lifetime 1,000,000 times or more (Note 1)
Environment resistance IP65 (at initial status) (Note 2)
Dust prevention and drip-proof at the front panel (waterproof packing is used at the contact surface to board)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient humidity 20 to 85 %RH, Storage: 10 to 85 %RH
Electrostatic noise resistance 5,000 V or more (panel surface)
Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y, and Z directions for 10 min. each
Shock resistance 98 m/s2 or more acceleration (10G approx.) in X, Y, and Z directions for four times each
Material Case: PPE, Front protective sheet: Polyester
Weight 230 g approx.
Accessory Connector cable for connecting the controller to the console : 1 pc., Mounting bracket: 1 set

Notes:
1) This value indicates the average lifetime of the unit when used under a normal temperature of 25 ℃ +77 ℉.
2) When reinstalling the console, replace the water proof packing. (Part No: AIGT181, 10 packs included)

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region