AUTOMATION
CONTROLS

Search
Discontinued
Products



Ultra-compact Laser Collimated Beam Sensor HL-T1

Ultra-compact sensor head
A high-functionality intelligent controller

Ultra-compact Laser Collimated Beam Sensor HL-T1
CE Marking FDA

CE , FDA Approved
FDA :HL-T□F only

Features

Ultra-compact sensor head

The ultra-compact size and yet the high level of performance. These sensors save space.

HL-T1001A(F) HL-T1005A(F) HL-T1010A(F)

Resolution of 4 μm 0.157 mil

A high resolution of 4 μm 0.157 mil (at an average 64 cycles) allows high-precision positioning and size judgment.

Resolution of 4 μm 0.157 mil

Long sensing range

Long sensing range of 500 mm 19.685 in [HL-T1005A(F), HL-T1010A(F)] and 2 m 6.562 ft [HL-T1001A(F)] are available.

High-precision judgment even from minute differences in light intensity

The sensors are sensitive to minute differences in light intensity, so that they can judge even the opacity of glass.
In addition, the amount of light received can be displayed as a percentage to allow you to determine permeation rates.

High-precision judgment even from minute differences in light intensity

Minimum sensing object diameter ø8 μm ø0.315 mil [HL-T1001A(F)]

The laser with a beam diameter of ø1 mm ø0.039 in can sense extremely small objects with dimensions in micrometers such as bonding wires.

Minimum sensing object diameter ø8 μm <span class=

Adoption of a Class 1 laser

The adoption of a Class 1 laser (IEC / JIS) eliminates the need for safety countermeasures, so that these sensors can be used in photoelectric sensor applications with confidence.

Fully equipped with convenient functionality

A wide range of convenient features has been incorporated into the unit's compact body: standard laser beam reception intensity setting / auto scaling setting / measurement processing (various timer and hold functions) / differentiation / monitor focus function.
These features make the unit useful for a wide variety of applications.

Detection resolution can be easily confirmed

The current resolution can be easily confirmed by setting the controller to indicate resolution display mode.
By displaying the resolution, the marginal increment can be easily determined for the threshold value setting, helping to accurately determine whether sensing can be performed.

Detection resolution can be easily confirmed

3 types of teaching functions are now available

3 types of teaching functions are available: positioning teaching / 2-point teaching / automatic teaching, thus enabling a variety of applications to be accommodated for many different types of production sites.

3 types of teaching functions are now available

Analog output is switchable between current / voltage

The analog output can be switched between either of two different outputs; current (4 to 20 mA) / voltage (±4 V). With the monitor focus function, the output can be adjusted over the range from -5 V to +5 V, or from 0 V to +5 V, facilitating connectivity with a variety of output devices.

Monitor focus function

The linear output is fully adjustable over the following range (current: 4 to 20 mA / voltage: ±4 V). The usage of the monitor focus function together with selectable current / voltage switching for the linear output allows for compatibility with a variety of output devices.

Monitor focus function
The linear output must be set by determining output values (maximum; current: 0 to 23.5 mA / voltage: ±5.5 V) at two different points, for the arbitrary display value.

FDA regulations conforming types are available

FDA regulations conforming types, most suitable for equipment used in the USA, are now available.

- FDA : Class II
- IEC / JIS : Class 1

Superior operability has been achieved

All settings can be easily performed by using the fourway keys and viewing the digital displays.

Superior operability has been achieved

Calculations for 2 sensors are possible

The calculation unit (optional) just needs to be connected between the two controllers to enable calculations (addition and subtraction) to be carried out for two sensors. No digital panel controller is needed either.

Calculations for 2 sensors are possible

Self-check for laser diode deterioration

The intelligent controller performs self-checking for laser diode deterioration. If the controller detects significant deterioration (end of diode life), an error will be displayed on the main digital display panel. This function enables users to prepare in advance for potential laser diode malfunctions.

Self-check for laser diode deterioration

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)