AUTOMATION
CONTROLS

Search
Discontinued
Products



Communication Unit for Digital Displacement Sensors SC-HG1

Specifications

EtherCAT communication unit

Model No. SC-HG1-ETC
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Compatible controllers HG-SC□, HG-TC□
Maximum number of
connectable controllers
Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-ETC unit
Supply voltage (Note 2) 24 V DC ±10 %, including ripple 0.5 V (P-P)
Current consumption 100 mA or less
Communication protocol EtherCAT
Compliance IEEE 802.3u (100BASE-TX)
Communication speed 100 Mbps (100BASE-TX)
Communication connector RJ-45×2
Node-to-node distance 100 m 328.084 ft or less
Supported functions Process data object communication (cyclic communication)
Mailbox communication (message communication) CoE
Explicit Device Identification
Station Alias
Pollution degree 2
Operating altitude (Note 3) 2,000 m 6,561.68 ft or less
Environmental
resistance
Ambient
temperature
-10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed),
Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient
humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Voltage
withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation
resistance
20 MΩ or higher, using 250 V DC megger between all supply terminals connected together and enclosure
Vibration
resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz),
maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Shock
resistance
98 m/s2 (10 G approx.) acceleration in X, Y, and Z directions five times each
Grounding method Casing: Floating type
Material Enclosure : Polycarbonate
Communication cable Category 5e (shielded twisted pair cable recommended)
Weight Net weight: 90 g approx.
Gross weight: 150 g appox.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Power is supplied from a connected controller / master controller.
3) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.

CC-Link IE Field Communication Unit for Digital Displacement Sensors

Model No. SC-HG1-CEF
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Compatible controllers HG-SC□, HG-TC□
Maximum number of connectable controllers Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑CEF unit
Supply voltage(Note 2) 24V DC ±10%, including 0.5V ripple (P-P)
Current consumption 200 mA or less
Communication method CC-Link IE Field
Remote station type Remote device station
Network No. setting 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or more: Error)(Note 3)
Cyclic transmission
(Maximum number of
links per station)
RX/RY:128 points each (128 bits), 16 bytes,
RWr/RWw: 64 points each (64 words), 128 bytes
Transient transmission Server function only, data size 1024 bytes
Station No. setting 1 to 120 (decimal) (0 and 121 or more: Error)
Communication speed 1 Gbps
Transmission line type Line, star, (mixing of line and star types is possible), ring
Maximum transmission distance 100 m 328.084 ft
Maximum number of units connectable 121 units (1 master station, 120 slave stations)
Cascade connection levels Maximum 20
Pollution degree 2
Operating altitude 2,000 m 6561.68 ft or less(Note 4)
Environmental
resistance
Protection IP40 (IEC)
Ambient temperature -10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed)
Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage
withstandability
1,000 V AC for one min. between all supply terminals
connected together and enclosure
Insulation
resistance
20 MΩ or more, with 250 V DC megger between all supply
terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions
five times each
Material Enclosure: Polycarbonate
Communication cable Ethernet cable that satisfies 1000BASE-T standard Category
5e or higher (Double-shielded / STP, straight cable)(Note 5)
Weight Net weight: 100 g approx., Gross weight: 150 g approx.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used
were ambient temperature +20 ℃ +68 ℉.
2) Power is supplied from a connected controller / master controller.
3) For the network number setting on this product, convert the network number to hex and
set the hex value.
4) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
5) Use CC-Link Partner Association recommended cable.

CC-Link Communication Unit for Digital Displacement Sensors

Model No. SC-HG1-C
Applicable regulations CE Marking (EMC Directive (Note 2), RoHS Directive), UKCA Marking (EMC Regulations (Note 2), RoHS Regulations)
Compatible controllers HG-SC□, HG-TC□
Maximum number of connectable controllers Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-C unit
Supply voltage (Note 3) 24 V DC ±10 %, including 0.5 V ripple (P-P)
Current consumption 80 mA or less
Communication method Switchable CC-Link Ver.1.10 or 2.00
Remote station type Remote device station
Number of occupied station CC-Link Ver.1.10: 4 stations, CC-Link Ver.2.00: Switchable 2 or 4 stations
Station No. setting 1 to 64 (0 and 65 or more: Error)
Communication speed 10 Mbps 5 Mbps 2.5 Mbps 625 kbps 156 kbps
Maximum transmission
distance
100 m
328.084 ft
160 m
524.934 ft
400 m
1,312.336 ft
900 m
2,952.756 ft
1,200 m
3,937.008 ft
Pollution degree 2
Operating altitude 2,000 m 6561.68 ft or less (Note 4)
Environmental
resistance
Protection IP40 (IEC)
Ambient temperature -10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Material Enclosure: Polycarbonate
Communication cable Specified cable (shielded twisted cable) (Note 5)
Weight Net weight: 80 g approx., Gross weight: 130 g approx.

Notes:

1) Where measurement conditions have not been specified precisely,
the conditions used were ambient temperature +20℃+68℉.
2) If our product will be incorporated in a customer product that will comply with the EMC Directive / EMC Regulations , install our product in a conductive box in accordance with "PLC User's Manual [Published by Mitsubishi Electric Corporation]".
3) Power is supplied from a connected controller / master controller.
4) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
5) Use only a special-use communication cable that is approved by the CC-Link Partner Association.

RS-485 Communication Unit for Digital Displacement Sensors

Model No. SC-HG1-485
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Compatible controllers HG-SC□, HG-TC□
Supply voltage (Note 2) 24 V DC ±10 %, Ripple P-P 10 % or less (Within specified power supply voltage range)
Current consumption 40 mA or less
Communication method Two-wire half duplex communication
Synchronization method Start-stop synchronization
Communication protocol MODBUS (RTU / ASCII) / MEWTOCOL-COM
Communication speed 1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 115.2 kbps
Electrical characteristics Complies with EIA RS-485
Number of
connectable
units
Host (RS-485) 1 to 99 units when MODBUS (RTU/ASCII) is used, 1 to 64 units when MEWTOCOL-COM is used
Controllers Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-485 unit
Stop bit length 1 bit / 2 bits
Parity check Even / Odd / None
Data bit length 8 bits (RTU) / 7 bits (ASCII)
Pollution degree 2
Operating altitude 2,000 m 6561.68 ft or less (Note 3)
Environmental
resistance
Protection IP40 (IEC)
Ambient temperature -10 to +45 ℃ 14 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Material Enclosure: Polycarbonate
Total extension distance Communication cable: 1,200 m 3,937.008 ft or less between SC-HG1-485 (terminal) and PLC
Weight Net weight: 75 g approx., Gross weight: 120 g approx.
Accessories Termination resistor switching jumper pin: 1 pc.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20℃ +68 ℉.
2 Power is supplied from a connected controller / master controller.
3 Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)