AUTOMATION
CONTROLS

Search
Discontinued
Products



Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100

Specifications

Sensor heads

Type Compound pressure Positive pressure Vacuum pressure
±100 kPa type 1 MPa type -101 kPa type
Model No.(Note 3) DPH-101(-R) DPH-101-M3(-R) DPH-101-M5(-R) DPH-102 DPH-102-M5(-R) DPH-103(-R) DPH-103-M3(-R) DPH-103-M5(-R)
CE marking directive compliance EMC Directive, RoHS Directive
Type of pressure Gauge pressure
Rated pressure range -100.0 to +100.0 kPa 0 to +1.000 MPa 0 to -101.0 kPa
Pressure withstandability 500 kPa 1.5 MPa 500 kPa
Applicable fluid Air, non-corrosive gas
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 15 mA or less
Analog voltage output Output voltage: 1 to 5 V (over rated pressure range)
Zero point: within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span: within 4 V ± 3.5 % F.S.
Linearity: within ±0.5 % F.S.
Output impedance: 1 kΩ approx.
Protection IP40 (IEC)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Temperature characteristics Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉: within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
Pressure port DPH-10□(-R): R1/8 male thread + M5 female thread, DPH-10□-M3(-R): M3 male thread (for installing gasket)
DPH-10□-M5(-R): M5 male thread (for installing gasket)
Material Front case: PBT, Rear case: PBT (glass fiber reinforced), Pressure port: Stainless steel (SUS303), O-ring: NBR
Pressure element: Silicon diaphragm, PPS
Connecting method Connector
Cable 0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have flexible, oil-resistant cabtyre cable)
Cable extension Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Weight Net weight DPH-10□(-R): Head 10 g approx. / Cable 40 g approx., DPH-10□-M3/M5(-R): Head 6 g approx. / Cable 40 g approx.
Gross weight DPH-10□(-R): 80 g approx., DPH-10□-M3/M5(-R): 70 g approx.
Accessory Connector (e-CON): 1 pc.

Note 1 :Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
Note 2 :The sensor head can be used independently.
Note 3 :Model No. having the suffix "-R" is bending-resistant cable type. The bending-resistant cable type of DPH-102 is not available.

Controllers

Type NPN output type PNP output type
Model No. DPC-101 DPC-101-P
CE marking directive compliance EMC Directive, RoHS Directive
Applicable sensor head DPH-101□, DPH-102□, DPH-103□
Rated pressure range
(Note 2)
Compound pressure: -100.0 to +100.0 kPa,
Positive pressure: 0 to +1.000 MPa,
Vacuum pressure: 0 to -101.0 kPa
Set pressure range
(Note 2)
Compound pressure: -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
Positive pressure: -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
Vacuum pressure: +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Power consumption Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD): 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL): 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Sensor head supply voltage Same as supply voltage
Comparative outputs
(Comparative output 1, 2)
NPN open-collector transistor (2 outputs)
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less
(between comparative output and 0 V)
・Residual voltage: 2 V or less (at 100 mA sink current)
PNP open-collector transistor (2 outputs)
・Maximum source current: 100 mA
・Applied voltage: 30 V DC or less
(between comparative output and +V)
・Residual voltage: 2 V or less (at 100 mA source current)
  Output operation NO / NC, selectable by key operation
Output modes EASY mode / Hysteresis mode / Window comparator mode
Hysteresis Minimum 1 digit (variable) (however, 2 digits when using psi unit)
Repeatability With vacuum / positive pressure type connected: within ±0.2 % F.S. (±2 digits)
With compound pressure type connected: within ±0.2 % F.S. (±4 digits)
Response time 0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Short-circuit protection Incorporated
Analog output <Analog voltage output>
・Output current: 1 to 5 V DC
・Zero point: within 1 V ± 0.5 % F.S.
(vacuum / positive pressure type)
within 3 V ± 0.5 % F.S. (compound pressure type)
・Span: within 4 V ± 0.5 % F.S.
・Linearity: within ±0.1 % F.S.
・Output impedance: 1 kΩ approx.

<Analog current output>
・Output current: 4 to 20 mA
・Zero point: within 4 mA ± 1 % F.S.
(vacuum / positive pressure type)
within 12 mA ± 1.5 % F.S. (compound pressure type)
・Span: within 16 mA ± 1.5 % F.S.
・Linearity: within ±0.1 % F.S.
・Load resistance: 250 Ω (max.).
Inputs Sensor head input Input voltage range: 1 to 5 V DC (over rated pressure range)
External input
(Auto-reference function/Remote zero-adjustment function)
ON voltage: +0.4 V DC or less
OFF voltage: +5 to +30 V DC, or open
Input impedance: 10 kΩ approx.
Input time: 1 ms or more
ON voltage: +5 V to +V DC
OFF voltage: +0.6 V DC or less, or open
Input impedance: 10 kΩ approx.
Input time: 1 ms or more
Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
  Displayable pressure range Vacuum pressure: +5.1 to -101.3 kPa,
Positive pressure: -0.050 to +1.020 MPa,
Compound pressure: -101.3 to +105.0 kPa
Operation indicator Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator: Lights up when each comparative output is ON)
Protection IP40 (IEC)
Ambient temperature -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Temperature characteristics Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
Material Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method Connector
Cable length Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Weight Net weight: 25 g approx. (excluding connector attached cable), Gross weight: 140 g approx.
Accessories CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set

Note 1 :Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
Note 2 :It changes automatically according to the connected pressure sensor head.
Note 3 :The values specified above are applied only to the controller.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)