Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Pressure Sensors / Flow Sensors > Pressure Sensors / Flow Sensors > Digital Pressure Controller PAD(Discontinued Products) > Specifications
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
|
Model No. | PAD-D1 | PAD-1 | PAD-2 | PAD-10 | PAD-50 | ||
---|---|---|---|---|---|---|---|
Applicable pressure sensor | PLX-D1L | PLX-1L | PLX-2L | PLX-10L | PLX-50L | ||
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | ||||||
Current consumption | 260 mA or less | ||||||
Power supply for sensor | 12 V DC +10 / 0 %, 70 mA or less | ||||||
Inputs | Sensor input | Range of input current: 4 to 20 mA (Maximum aliowable current: 50 mA) Input impedance: 20 Ω approx. Sampling cycle: 50 ms (20 times/sec.) |
|||||
Auto-reference input | Activating auto-reference function ・Operation: NPN non-contact input, edge trigger at signal falling ・Signal condition Low level: 1.5 V or less Low level output current: 0.6 mA or less Low level input time: 0.5 ms or more |
||||||
Outputs | Comparative outputs (HI, GO, LO) |
NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 30 V DC or less (between comparative output and 0 V) ・Residual voltage: 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) |
|||||
Output operation |
|||||||
Response time | 100 ms or less (150 ms or less during auto-reference active) | ||||||
Display | Measurement value display | 3 1/2 digit LCD display [Sampling cycle: 250 ms (4 times/sec.)] | |||||
Display range | +0.0 to +100.0 kPa | +0.000 to +1.000 MPa | +0.000 to +1.999 MPa | +0.00 to +10.00 MPa | +0.0 to +50.0 MPa | ||
Setting value display | 3 1/2 digit LCD display | ||||||
Setting range | -199.9 to +199.9 kPa | -1.999 to +1.999 MPa | -1.999 to +1.999 MPa | -19.99 to +19.99 MPa | -199.9 to +199.9 MPa | ||
Comparative output display | "HI", "GO" or "LO" LCD display (HI, GO or LO lights up when the corresponding output is activated) |
||||||
Indication accuracy | ± (measurement value x 0.15 % + 1 digit) or less at 23 ± 1 ℃ 73.4 ± 33.8 ℉ | ||||||
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: -10 to +60 ℃ +14 to +140 ℉ | ||||||
Connection method | Terminal block | ||||||
Weight | 230 g approx. | ||||||
Dimensions | W72 x H72 x D88.2 mm W2.835 x H2.835 x D3.472 in |
(Note) : | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉ . |
---|
|