Ambient temperature -60 to +350℃*
Lens for vacuum-resistant fiber is also available.
|
*Expansion lens
Designation |
Model No. | Description | |
---|---|---|---|
Expansion lens (Note 1) |
FX-LE1 | ![]() |
Increases the sensing range by 5 times or more. ・ Ambient temperature: -60 to +350 ℃ -76 to +662 ℉ (Note 2) ・ Beam dia: ø3.6 mm ø0.142 in Sensing range (mm in) [Lens on both sides] |
Super-expansion lens (Note 1) |
FX-LE2 | ![]() |
Tremendously increases the sensing range with large diameter lenses. ・ Ambient temperature: -60 to +350 ℃ -76 to +662 ℉ (Note 2) ・ Beam dia: ø9.8 mm ø0.386 in Sensing range (mm in) [Lens on both sides] |
Side-view lens | FX-SV1 | ![]() |
Beam axis is bent by 90°. ・ Ambient temperature: -60 to +300 ℃ -76 to +572 ℉ (Note 4) ・ Beam dia: ø2.8 mm ø0.110 in Sensing range (mm in) [Lens on both sides] |
(Note 1): | Be careful sure to use it only after you have adjusted it sufficiently when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. |
---|---|
(Note 2): | Refer to "Fiber page" for the ambient temperature of fibers to be used in combination. |
Amplifiers | FX-500 series (Upper value) FX-550 / FX-550L series (Lower value) |
FX-100 series | ||||||
---|---|---|---|---|---|---|---|---|
Mode | HYPR | U-LG | LONG | STD | FAST | H-SP | FX-101 | FX-102 |
FT-43 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
1,600 - |
2,400 | 3,600 (Note 1) |
FT-42 FT-42W |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
2,200 - |
3,400 | 3,600 (Note 1) |
FT-45X | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,500 - |
1,600 (Note 1) |
1,600 (Note 1) |
FT-R40 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
1,900 - |
3,100 | 3,600 (Note 1) |
FT-R43 FT-R44Y |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
1,900 1,600 (Note 1) |
670 - |
1,300 | 3,600 (Note 1) |
FT-H35-M2 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,300 3,600 (Note 1) |
1,400 - |
2,000 | 3,500 (Note 1) |
FT-H20W-M1 | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
850 - |
1,300 | 1,600 (Note 1) |
FT-H20-M1 | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,200 - |
1,600 (Note 1) |
1,600 (Note 1) |
FT-H20-J50-S FT-H20-J30-S FT-H20-J20-S |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,500 3,600 (Note 1) |
2,000 3,600 (Note 1) |
1,600 3,600 (Note 1) |
500 - |
1,000 | 3,500 (Note 1) |
(Note 1): | The fiber cable length practically limits the sensing range. |
---|
Amplifiers | FX-500 series (Upper value) FX-550 / FX-550L series (Lower value) |
FX-100 series | ||||||
---|---|---|---|---|---|---|---|---|
Mode | HYPR | U-LG | LONG | STD | FAST | H-SP | FX-101 | FX-102 |
FT-43 FT-42 FT-42W |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) - |
3,600 (Note 1) |
3,600 (Note 1) |
FT-45X | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) - |
1,600 (Note 1) |
1,600 (Note 1) |
FT-R40 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) - |
3,600 (Note 1) |
3,600 (Note 1) |
FT-R41W FT-R43 FT-R44Y |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) - |
3,600 (Note 1) |
3,600 (Note 1) |
FT-H35-M2 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) - |
3,500 (Note 1) |
3,500 (Note 1) |
FT-H20W-M1 FT-H20-M1 |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) - |
1,600 (Note 1) |
1,600 (Note 1) |
FT-H13-FM2 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) - |
3,500 (Note 1) |
3,500 (Note 1) |
FT-H20-J50-S FT-H20-J30-S FT-H20-J20-S |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) - |
3,500 (Note 1) |
3,500 (Note 1) |
(Note 1): | The fiber cable length practically limits the sensing range. |
---|
Amplifiers | FX-500 series (Upper value) FX-550 / FX-550L series (Lower value) |
FX-100 series | ||||||
---|---|---|---|---|---|---|---|---|
Mode | HYPR | U-LG | LONG | STD | FAST | H-SP | FX-101 | FX-102 |
FT-43 | 3,600 (Note 1) 3,600 (Note 1) |
3,400 3,600 (Note 1) |
2,600 3,600 (Note 1) |
1,700 2,300 |
970 1,400 |
310 - |
510 | 1,400 |
FT-42 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
2,100 2,800 |
1,150 1,700 |
370 - |
500 | 1,700 |
FT-42W | 3,600 (Note 1) 3,600 (Note 1) |
3,500 3,600 (Note 1) |
2,700 3,600 (Note 1) |
1,800 2,300 |
990 1,400 |
320 - |
480 | 1,300 |
FT-45X | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,400 1,600 (Note 1) |
800 1,600 (Note 1) |
210 - |
540 | 1,600 (Note 1) |
FT-R43 | 3,200 3,600 (Note 1) |
1,800 3,600 (Note 1) |
1,300 2,700 |
950 1,900 |
510 1,200 |
160 - |
310 | 930 |
FT-R44Y | 3,200 3,600 (Note 1) |
1,800 3,600 (Note 1) |
1,300 3,200 |
950 2,200 |
510 1,400 |
160 - |
310 | 930 |
FT-H35-M2 | 3,500 3,600 (Note 1) |
1,600 2,800 |
1,200 1,800 |
780 1,300 |
500 750 |
150 - |
280 | 800 |
FT-H20W-M1 | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,500 1,600 (Note 1) |
950 1,250 |
560 690 |
190 - |
140 | 400 |
FT-H20-M1 | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,300 1,600 (Note 1) |
780 1,600 (Note 1) |
500 800 |
150 - |
280 | 840 |
FT-H20-J50-S FT-H20-J30-S FT-H20-J20-S |
1,600 (Note 1) 3,600 (Note 1) |
960 2,400 |
740 1,500 |
450 1,100 |
290 680 |
80 - |
150 | 410 |
(Note 1): | The fiber cable length practically limits the sensing range. |
---|
Designation |
Model No. | Description | |
---|---|---|---|
Expansion lens for vacuum fiber (Note 1) |
FV-LE1 | ![]() |
Sensing range increases by 4 times or more. ・ Ambient temperature: -60 to +350 ℃ -76 to +662 ℉ (Note 2) ・ Beam dia: ø3.6 mm ø0.142 in Sensing range (mm in) [Lens on both sides] |
Vacuum-resistant compact side-view lens (Note 1) |
FV-SV1 | ![]() |
Beam axis is bent by 90°. ・ Ambient temperature: -30 to +300 ℃ -22 to +572 ℉ (Note 2) ・ Beam dia: ø3 mm ø0.118 in Sensing range (mm in) [Lens on both sides] |
Vacuum-resistant side-view lens (Note1) |
FV-SV2 | ![]() |
Beam axis is bent by 90°. ・ Ambient temperature: -60 to +300 ℃ -76 to +572 ℉ (Note 2) ・ Beam dia: ø3.7 mm ø0.146 in Sensing range (mm in) [Lens on both sides] |
(Note 1): | Be careful sure to use it only after you have adjusted it sufficiently when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. |
---|---|
(Note 2): | Refer to "Fiber page" for the ambient temperature of fibers to be used in combination. |
Amplifiers |
FX-500 series (Upper value) FX-550 / FX-550L series (Lower value) |
FX-100 series | ||||||
---|---|---|---|---|---|---|---|---|
Mode | HYPR | U-LG | LONG | STD | FAST | H-SP | FX-101 | FX-102 |
FT-40V (Note 2) |
1,800 (Note 1) 1,800 (Note 1) |
1,800 (Note 1) 1,800 (Note 1) |
1,800 (Note 1) 1,800 (Note 1) |
1,500 1,800 (Note 1) |
900 1,650 |
370 - |
450 | 1,600 |
FT-H30-M1V-S (Note 3) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,400 3,600 (Note 1) |
1,500 2,500 |
900 1,650 |
370 - |
450 | 1,600 |
(Note 1): | The fiber cable length practically limits the sensing range. |
---|---|
(Note 2): | The fiber cable length for the FT-40V is 1 m 3.281 ft. The sensing ranges take into account the length of the FT-J9 atmospheric side fiber. |
(Note 3): | The fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series, in FX-102□ take into account the length of the FT-J8 atmospheric side fiber. |
Amplifiers | FX-500 series (Upper value) FX-550 / FX-550L series (Lower value) |
FX-100 series | ||||||
---|---|---|---|---|---|---|---|---|
Mode | HYPR | U-LG | LONG | STD | FAST | H-SP | FX-101 | FX-102 |
FT-40V (Note 2) |
1,800 (Note 1) 1,800 (Note 1) |
900 1,800 (Note 1) |
700 1,050 |
450 720 |
290 430 |
90 - |
150 | 460 |
FT-H30-M1V (Note 3) |
1800 2300 |
900 1800 |
700 1050 |
450 720 |
290 430 |
90 - |
150 | 460 |
(Note 1): | The fiber cable length practically limits the sensing range. |
---|---|
(Note 2): | The fiber cable length for the FT-40V is 1 m 3.281 ft. The sensing ranges take into account the length of the FT-J9 atmospheric side fiber. |
(Note 3): | The fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series, in FX-102□ take into account the length of the FT-J8 atmospheric side fiber. |
Amplifiers | FX-500 series (Upper value) FX-550 / FX-550L series (Lower value) |
FX-100 series | ||||||
---|---|---|---|---|---|---|---|---|
Mode | HYPR | U-LG | LONG | STD | FAST | H-SP | FX-101 | FX-102 |
FT-40V (Note 2) |
1,800 (Note 1) 1,800 (Note 1) |
1,800 (Note 1) 1,800 (Note 1) |
1,800 (Note 1) 1,800 (Note 1) |
1,500 1,800 (Note 1) |
900 1,100 |
370 - |
450 | 1,600 |
FT-H30-M1V-S (Note 3) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,400 3,600 (Note 1) |
1,500 1,800 |
900 1,100 |
370 - |
450 | 1,600 |
(Note 1): | The fiber cable length practically limits the sensing range. |
---|---|
(Note 2): | The fiber cable length for the FT-40V is 1 m 3.281 ft. The sensing ranges take into account the length of the FT-J9 atmospheric side fiber. |
(Note 3): | The fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series, in FX-102□ take into account the length of the FT-J8 atmospheric side fiber. |
|