Digital Fiber Sensor FX-410

Specifications

Type Red LED Blue LED Green LED
Model No. NPN output FX-411 FX-411B FX-411G
FX-412 (Note 2) FX-412B (Note 2) FX-412G (Note 2)
PNP output FX-411P FX-411BP FX-411GP
CE marking directive compliance EMC Directive, RoHS Directive
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption <Red LED type>
Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage)
<Blue LED / Green LED type>
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 580 mW or less (Current consumption 24 mA or less at 24 V supply voltage)
Output <NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA
(50 mA, if five, or more, amplifiers are connected in cascade)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less
[at 100 mA sink current
(50 mA, if five, or more, amplifiers are connected in cascade)]

<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA
(50 mA, if five, or more, amplifiers are connected in cascade)
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less
[at 100 mA sink current
(50 mA, if five, or more, amplifiers are connected in cascade)]
  Utilization category DC-12 or DC-13
Output operation Switchable either Light-ON or Dark-ON
Short-circuit
protection
Incorporated
Response time 150 μs or less (FAST), 500 μs or less (STD), 4.5 ms or less (U-LG) selectable with setting switch
Operation indicator Orange LED (lights up when the output is ON)
Stability indicator Green LED (lights up under stable light received condition or stable dark condition)
Timer function Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective.
[Timer period (Note 3): 1 ms to 3 sec. approx. (1 to 10 ms: Setting possible in units of 1 ms, 10 to 100 ms: Setting possible in units of 10 ms,
100 to 500 ms: Setting possible in units of 50 ms, 500 ms to 1 sec.: Setting possible in units of 100 ms, 1 to 3 sec.: Setting possible in units of 500 ms)]
Automatic interference
prevention function
Incorporated (Up to four sets of fiber heads can be mounted close together. However, U-LG mode is 8 fiber heads.)(Note 4)
Pollution degree 3 (Industrial environment)
Ambient temperature –10 to +55 ℃ –14 to +131 ℉
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
(No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 5)
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 5)
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Emitting element (modulated) Red LED Blue LED Green LED
  Peak emission
wavelength
650 nm 0.026 mil 470 nm 0.019 mil 525 nm 0.021 mil
Material Enclosure: Heat-resistant ABS, Case cover: Polycarbonate
Cable length Total length up to 100 m 328.084 ft (50 m 164.042 ft for 5 to 8 units, 20 m 65.617 ft for 9 to 16 units) is possible with 0.3 mm2, or more, cable.
Weight Net weight: 20 g approx., Gross weight: 30 g approx.

Notes:

1): Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2): The FX-412□ has a threshold value adjuster that can be adjusted with your fingers.
3): For models manufactured up until June 2005, the timer period is approx. 1 to 500 ms.
4): When the power supply is switched on, the light emission timing is automatically set for interference prevention.
5): The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)