AUTOMATION
CONTROLS

Search
Discontinued
Products



Cylindrical Photoelectric Sensor CY-100 SERIES (Discontinued Products)

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Mounting

  • The tightening torque should be 3 N·m or less.
  • Use a cable with connector CN-24C(L)-C□ (optional) for M12 connector type.
    Tightening torque for connector part is 2 N·m or less.

Mounting

Mounting drawing with sensor or reflector RF-420

Mounting drawing with sensor or reflector RF-420

Wiring

  • Make sure that the power supply is off while wiring.
  • Verify that the supply voltage variation is within the rating.
  • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
  • Ensure that an isolation transformer is utilized for the DC power supply.
    If an autotransformer is utilized, the main body or power supply may be damaged.
  • If the used power supply generates a surge, connect a surge absorber to the power supply to absorb the surge.
  • Do not use during the initial transient time (0.5 sec) after the power supply is switched on.
  • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
  • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway.
    This can cause malfunction due to induction.
  • Damage or burnout may result in case of short circuit of load or miswiring.
  • Make a cable length as short as possible to lessen noise pickup.

Others

  • This device has been developed / produced for industrial use only.
  • Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance.
  • Avoid using a product where there is excessive vapor, dust or corrosive gas,
    or in a place where it could be exposed directly to water or chemicals.
  • Take care that the sensor does not come in direct contact with water, oil, grease or organic solvents,
    such as, thinner, etc.
  • Do not use in an environment containing infammable or explosive gases.
  • Never disassemble or modify the product.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)