CMOS type Micro Laser Distance Sensor HG-C

Reliable detection in repeatability 10 μm 0.394 mil

HG-C
UL C-UL Recognaized CE Marking FDA

UL/C-UL , CE , FDA Approved

  • This product is classified as a Class 2 Laser Product under IEC / JIS / GB standards and FDA regulations. Do not look at the laser beam directly or through an optical system such as a lens.

* This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).

Features

Overwhelmingly stable

Fitted with a precise CMOS image sensor and an original algorithm

Thanks to a precise CMOS image sensor, it is now possible to perform highly precise measurements in the order of 1/100 mm 0.0003 in.
The existing adjustable range reflective sensors cannot achieve such accuracy.


Repeatability 10μm (0.394 mil) [HG-C1030(-P)]

Compact and light-weight

The HG-C series is the smallest CMOS laser sensor in industry *. W20 × H44 × D25 mm W0.787 × H1.732 × D0.984 in, 35 g approx. (without cable)
* As of May 2015, in-company survey.

A new optical system with a built-in mirror
In general, more accurate and stable measurements can be obtained by increasing the optical path length between the light-receiving part and the light receiving element (CMOS), but this also increases the sensor depth and the sensor body gets bigger. The HG-C series sensors incorporating a new optical system with a built-in mirror provides smaller sensor depth as well as higher measurement accuracy equivalent to displacement sensors.

A new optical system with a built-in mirror

An aluminum die-cast casing protects from strain and heat
A light-weight but strong die-cast aluminum casing has been adopted. A compact, solid body casing reduces the impact of strain and heat on the measurement accuracy.

An aluminum die-cast casing protects from strain and heat

Equipped with 0 to +5 V analog output and 4 to 20 mA analog current output [HG-C1□0(-P)]

The value can be measured with a distance measurement sensor. ・Linearity: ±0.1% F.S.* ・Temperature characteristics: 0.03%F.S./℃
*HG-C1030(-P) / HG-C1050(-P) / HG-C1100(-P)

The sensor not only indicates measured values in mm but also produces analog outputs. Various calculations and storage (logging) can be performed when output is taken into a PLC + analog unit.

Equipped with 0 to 5 V analog output

FP0R-C10 control unit (with RS232C port) AFP0RC10CRS
A/D converter unit with input channels (terminal block type) AFP0RAD8

■Linearity characteristics
[Typical example: HG-C1030(-P)]

Linearity characteristics [Typical example: HG-C1030(-P)]

Useful functions

Teaching & window comparator mode

With an object below the sensor, press the TEACH key to set the valid range for distances via threshold values. There are 3 methods for setting the valid range: 1-point, 2-point, and 3-point teaching.

1-point teaching





Perform 1-point teaching and the threshold range is set for the distance from the reference surface of the sensing object.
This is used for sensing within the threshold range.

2-point teaching





Press TEACH once for the lower (first point) and once for the upper limit (second point).

3-point teaching



This is the method to set the threshold range by conducting the teaching at 3 points (sensing object A, B and C). After teaching, the reference points are automatically sorted in ascending order (reference point 1, 2 and 3). The thresholds are set at the midpoints between reference point 1 and 2, and 2 and 3, respectively.


In addition to the teaching & window comparator mode, the “rising differential mode”, “trailing differential mode” and “normal sensing mode” are available.
In normal sensing mode, “2-point teaching” as basic teaching and “limit teaching,” which is useful for very small objects and backgrounds, are possible.

Timer setting function

The time mode options are “off-delay timer,” “on-delay timer,” “one-shot timer” and “no timer.” The counting time is fixed to 5 ms.

Timer setting function

Timer period: 5 ms (fixed)

Off-delay timer
Function : Extends output signals by 5 ms.
Usage : Appropriate in case a connected device is slow to respond and ON time is required to extend.

On-delay timer
Function: Overrides output signals for 5 ms after detection.
Usage: Convenient way to override temporary signals and control with a time lag.

One-shot timer
Function: Sends output signals for only 5 ms after detection.
Usage: Useful when the signal duration needs to be constant to meet inputs from a connected device.
This mode is also used to extend temporary signals by a desired length of time.

Zero set function
This function compulsorily sets the measured value to “zero.”
The zero point can be set at a desired value. It is useful when measuring steps or tolerance with reference to the height of a sensing object.

Zero set function
* The zero set indicator (yellow) will turn ON while the zero set is valid.
* When the zero set function is executed while the peak hold function or the bottom hold function is valid, the held measurement value is reset.
* When the display setting is set to offset, the zero set function cannot be set.

External input setting function
One of four functions, “zero setting function,” “teaching function,” “emission stopping function” and “trigger function” can be assigned to an external input line.

External input setting function

Display setting function
How to indicate measured values of the moving sensed object can be chosen from three options, “Normal,” “Invert” and “Offset.”

Example:HG-C1050(-P)

Display setting function

Peak and bottom hold functions

The peak hold function holds the maximum measured value which is output and displayed.
The bottom hold function holds the minimum measured value which is output and displayed.
* The peak hold function and the bottom hold function cannot be set at the same time.
* When the zero set function is executed while the peak hold function or the bottom hold function is valid, the held measurement value is reset.

Threshold value fine adjustment function

Fine adjustment of threshold values can be performed while measurement is proceeding on the display, and even after teaching.

Key lock function

This function protects setting conditions from unintentional changes.

* For other functions and procedures for setting the functions, see the instruction manual provided with the product.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE SEARCH FAQ

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



BY PHONE

FAQ


Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)