Creating safety circuits is easier than ever!
|
![]() |
![]() |
![]() |
![]() |
UL
, CE
, CSA
, TUV
, UKCA
Approved
CE : Machinery Directive, EMC Directive
UL, CSA : Certified by TÜV SÜD America Inc. (NRTL)
![]() |
![]() |
The control category differs depending on the configuration and wiring of the external circuit.
One SF-C21 can do the work of four safety relay units. |
![]() |
![]() |
Small, so the unit can be installed in a narrow space Long-life semiconductor output (PNP) adopted for control output and auxiliary output |
![]() |
Easy to monitor status with a generalpurpose PLC |
![]() Note: Communication information can not be used for safety control. |
Simply turn a switch to set |
![]() |
|
|
Refer to " 8 preset logics"
Easy to set the "OFF delay"
The OFF delay time can be easily set by simply turning the rotary switch to any one of patterns.
Pattern No. | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
---|---|---|---|---|---|---|---|---|---|---|
OFF delay time (sec.) | 0 | 0.1 | 0.5 | 1 | 2 | 5 | 10 | 15 | 30 | 60 |
* The OFF delay time applies to control output 2. In case of setting the OFF delay time to control output 1, the "Configurator SF-C" software is needed.
Password protection prevents inadvertent logic changes
Easy to create a reliable safety circuit Use our "Configurator SF-C" software to build your own safety circuits of connected devices, control logic, output modes, etc. No programming skills required! |
![]() |
Customized logics are safety-certified too!! |
![]() |
Note:
Please make sure that the combination of logics and input devices complies with each machine safety standard.
Logic No.1:Overall stop control
![]() |
When any connected input becomes OFF, the entire control output will be OFF. |
Logic No.2:Parallel muting control
![]() |
When the muting input becomes ON, the light curtain will be temporarily disabled. |
Logic No.3:Sequential muting control
![]() |
Only when the muting input becomes ON following a predefined sequence, the light curtain will be temporarily disabled. |
Logic No.4:Partial stop control 1
![]() |
When the emergency stop input is OFF, the entire control output will be OFF. When any other input is OFF, its corresponding control output will be OFF. |
Logic No.5:Partial stop control 2
![]() |
When the emergency stop input or the input from the back-end process becomes OFF, the entire control output will be OFF. When the input from the front-end process becomes OFF, only its corresponding control output will be OFF. |
Logic No.6:Two-hand control
![]() |
This control is applied when a two-hand operation switch is used for control.Only when both switches of the two-hand operation switch are operated within 0.5 sec., control output will be ON. |
Logic No.7:OR control
![]() |
Even when the guard (input A) is OFF, if the enabling switch is ON the control output will be ON. If either the emergency switch or input B becomes OFF, the entire control output will be OFF regardless of the status of the input A and emergency switch. |
Logic No.8:Operation mode selection control
![]() |
Only when mode selection using the key selector is followed by the enabling switch being turned ON, the control output will be ON regardless of the open / close status of the guard. |