Type | Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-F15(-01) | SF4D-F23(-01) | SF4D-F31(-01) | SF4D-F39(-01) | |
Number of beam channels |
15 | 23 | 31 | 39 | |
Protective height (Note 2) |
150 mm 5.906 in |
230 mm 9.055 in |
310 mm 12.205 in |
390 mm 15.354 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
140 mm 5.512 in |
220 mm 8.661 in |
300 mm 11.811 in |
380 mm 14.961 in |
|
Current consumption | Emitter:110 mA or less Receiver:130 mA or less |
Emitter:120 mA or less Receiver:130 mA or less |
Emitter:120 mA or less Receiver:140 mA or less |
||
PFHD | 1.21×10-9 | 1.48×10-9 | 1.80×10-9 | 2.07×10-9 | |
MTTFD | 1,031 years or more | 833 years or more | 672 years or more | 582 years or more | |
Net weight (Total of emitter and receiver) |
270g approx. | 470g approx. | 680g approx. | 890g approx. |
Type | Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-F47(-01) | SF4D-F55(-01) | SF4D-F63(-01) | SF4D-F71(-01) | |
Number of beam channels |
47 | 55 | 63 | 71 | |
Protective height (Note 2) |
470 mm 18.504 in |
550 mm 21.654 in |
630 mm 24.803 in |
710 mm 27.953 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
460 mm 18.110 in |
540 mm 21.260 in |
620 mm 24.409 in |
700 mm 27.559 in |
|
Current consumption | Emitter:120 mA or less Receiver:140 mA or less |
Emitter:120 mA or less Receiver:150 mA or less |
|||
PFHD | 2.40×10-9 | 2.66×10-9 | 2.99×10-9 | 3.25×10-9 | |
MTTFD | 498 years or more | 447 years or more | 396 years or more | 363 years or more | |
Net weight (Total of emitter and receiver) |
1,100g approx. | 1,300g approx. | 1,500g approx. | 1,700g approx. |
Type | Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-F79(-01) | SF4D-F95(-01) | SF4D-F111(-01) | SF4D-F127(-01) | |
Number of beam channels |
79 | 95 | 111 | 127 | |
Protective height (Note 2) |
790 mm 31.102 in |
950 mm 37.402 in |
1,110 mm 43.701 in |
1,270 mm 50.000 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
780 mm 30.709 in |
940 mm 37.008 in |
1,100 mm 43.307 in |
1,260 mm 49.606 in |
|
Current consumption | Emitter:120 mA or less Receiver:150 mA or less |
Emitter:120 mA or less Receiver:160 mA or less |
Emitter:120 mA or less Receiver:170 mA or less |
Emitter:120 mA or less Receiver:180 mA or less |
|
PFHD | 3.58×10-9 | 4.17×10-9 | 4.76×10-9 | 5.36×10-9 | |
MTTFD | 328 years or more | 281 years or more | 245 years or more | 217 years or more | |
Net weight (Total of emitter and receiver) |
1,900g approx. | 2,300g approx. | 2,800g approx. | 3,200g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years). |
---|---|
2) | When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-H8(-01) | SF4D-H12(-01) | SF4D-H16(-01) | SF4D-H20(-01) | |
Number of beam channels |
8 | 12 | 16 | 20 | |
Protective height (Note 2) |
150 mm 5.906 in |
230 mm 9.055 in |
310 mm 12.205 in |
390 mm 15.354 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
140 mm 5.512 in |
220 mm 8.661 in |
300 mm 11.811 in |
380 mm 14.961 in |
|
Current consumption | Emitter:100 mA or less, Receiver:120 mA or less | ||||
PFHD | 9.57×10-10 | 1.12×10-9 | 1.26×10-9 | 1.40×10-9 | |
MTTFD | 1,340 years or more | 1,119 years or more | 988 years or more | 881 years or more | |
Net weight (Total of emitter and receiver) |
270g approx. | 470g approx. | 680g approx. | 890g approx. |
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-H24(-01) | SF4D-H28(-01) | SF4D-H32(-01) | SF4D-H36(-01) | |
Number of beam channels |
24 | 28 | 32 | 36 | |
Protective height (Note 2) |
470 mm 18.504 in |
550 mm 21.654 in |
630 mm 24.803 in |
710 mm 27.953 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
460 mm 18.110 in |
540 mm 21.260 in |
620 mm 24.409 in |
700 mm 27.559 in |
|
Current consumption | Emitter:100 mA or less Receiver:130 mA or less |
Emitter:110 mA or less Receiver:130 mA or less |
Emitter:120 mA or less Receiver:130 mA or less |
||
PFHD | 1.56×10-9 | 1.73×10-9 | 1.87×10-9 | 2.04×10-9 | |
MTTFD | 782 years or more | 701 years or more | 647 years or more | 591 years or more | |
Net weight (Total of emitter and receiver) |
1,100g approx. | 1,300g approx. | 1,500g approx. | 1,700g approx. |
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-H40(-01) | SF4D-H48(-01) | SF4D-H56(-01) | SF4D-H64(-01) | |
Number of beam channels |
40 | 48 | 56 | 64 | |
Protective height (Note 2) |
790 mm 31.102 in |
950 mm 37.402 in |
1,110 mm 43.701 in |
1,270 mm 50.000 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
780 mm 30.709 in |
940 mm 37.008 in |
1,100 mm 43.307 in |
1,260 mm 49.606 in |
|
Current consumption | Emitter:120 mA or less Receiver:140 mA or less |
Emitter:120 mA or less Receiver:150 mA or less |
|||
PFHD | 2.17×10-9 | 2.48×10-9 | 2.78×10-9 | 3.09×10-9 | |
MTTFD | 552 years or more | 481 years or more | 426 years or more | 383 years or more | |
Net weight (Total of emitter and receiver) |
1,900g approx. | 2,300g approx. | 2,800g approx. | 3,200g approx. |
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-H72(-01) | SF4D-H80(-01) | SF4D-H88(-01) | SF4D-H96(-01) | |
Number of beam channels |
72 | 80 | 88 | 96 | |
Protective height (Note 2) |
1,430 mm 56.299 in |
1,590 mm 62.598 in |
1,750 mm 68.898 in |
1,910 mm 75.197 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
1,420 mm 55.906 in |
1,580 mm 62.205 in |
1,740 mm 68.504 in |
1,900 mm 74.803 in |
|
Current consumption | Emitter:120 mA or less Receiver:150 mA or less |
Emitter:120 mA or less Receiver:160 mA or less |
|||
PFHD | 3.39×10-9 | 3.69×10-9 | 4.00×10-9 | 4.30×10-9 | |
MTTFD | 347 years or more | 318 years or more | 293 years or more | 272 years or more | |
Net weight (Total of emitter and receiver) |
3,600g approx. | 4,000g approx. | 4,400g approx. | 4,800g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years). |
---|---|
2) | When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
Type | Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-A4(-01) | SF4D-A6(-01) | SF4D-A8(-01) | SF4D-A10(-01) | |
Number of beam channels |
4 | 6 | 8 | 10 | |
Protective height (Note 2) |
150 mm 5.906 in |
230 mm 9.055 in |
310 mm 12.205 in |
390 mm 15.354 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
120 mm 4.724 in |
200 mm 7.874 in |
280 mm 11.024 in |
360 mm 14.173 in |
|
Current consumption | Emitter:100 mA or less, Receiver:120 mA or less | ||||
PFHD | 8.29×10-10 | 9.34×10-10 | 1.01×10-9 | 1.11×10-9 | |
MTTFD | 1,577 years or more | 1,378 years or more | 1,267 years or more | 1,136 years or more | |
Net weight (Total of emitter and receiver) |
270g approx. | 470g approx. | 680g approx. | 890g approx. |
Type | Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-A12(-01) | SF4D-A14(-01) | SF4D-A16(-01) | SF4D-A18(-01) | |
Number of beam channels |
12 | 14 | 16 | 18 | |
Protective height (Note 2) |
470 mm 18.504 in |
550 mm 21.654 in |
630 mm 24.803 in |
710 mm 27.953 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
440 mm 17.323 in |
520 mm 20.472 in |
600 mm 23.622 in |
680 mm 26.772 in |
|
Current consumption | Emitter:100 mA or less, Receiver:130 mA or less | ||||
PFHD | 1.18×10-9 | 1.29×10-9 | 1.36×10-9 | 1.46×10-9 | |
MTTFD | 1,060 years or more | 966 years or more | 910 years or more | 840 years or more | |
Net weight (Total of emitter and receiver) |
1,100g approx. | 1,300g approx. | 1,500g approx. | 1,700g approx. |
Type | Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-A20(-01) | SF4D-A24(-01) | SF4D-A28(-01) | SF4D-A32(-01) | |
Number of beam channels |
20 | 24 | 28 | 32 | |
Protective height (Note 2) |
790 mm 31.102 in |
950 mm 37.402 in |
1,110 mm 43.701 in |
1,270 mm 50.000 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
760 mm 29.921 in |
920 mm 36.220 in |
1,080 mm 42.520 in |
1,240 mm 48.819 in |
|
Current consumption | Emitter:100 mA or less Receiver:130 mA or less |
Emitter:100 mA or less Receiver:140 mA or less |
Emitter:110 mA or less Receiver:140 mA or less |
||
PFHD | 1.54×10-9 | 1.71×10-9 | 1.89×10-9 | 2.07×10-9 | |
MTTFD | 798 years or more | 710 years or more | 640 years or more | 582 years or more | |
Net weight (Total of emitter and receiver) |
1,900g approx. | 2,300g approx. | 2,800g approx. | 3,200g approx. |
Type | Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | SF4D-A36(-01) | SF4D-A40(-01) | SF4D-A44(-01) | SF4D-A48(-01) | |
Number of beam channels |
36 | 40 | 44 | 48 | |
Protective height (Note 2) |
1,430 mm 56.299 in |
1,590 mm 62.598 in |
1,750 mm 68.898 in |
1,910 mm 75.197 in |
|
When using as safety equipment for Chinese press machine or when using SF4D-□-01 for Japanese press machine or paper shearing machine |
1,400 mm 55.118 in |
1,560 mm 61.417 in |
1,720 mm 67.717 in |
1,880 mm 74.016 in |
|
Current consumption | Emitter:110 mA or less Receiver:150 mA or less |
Emitter:110 mA or less Receiver:160 mA or less |
|||
PFHD | 2.24×10-9 | 2.42×10-9 | 2.60×10-9 | 2.77×10-9 | |
MTTFD | 534 years or more | 493 years or more | 458 years or more | 428 years or more | |
Net weight (Total of emitter and receiver) |
3,600g approx. | 4,000g approx. | 4,400g approx. | 4,800g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. PFHd: Probability of Dangerous Failure per Hour, MTTFd: Mean Time to Dangerous Failure (in years). |
---|---|
2) | When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
Type | Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch) |
Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) |
|
---|---|---|---|---|
Model No. | SF4D-F□ | SF4D-H□ | SF4D-A□ | |
Japanese press machine or paper shearing machine compliant |
SF4D-F□-01 | SF4D-H□-01 | SF4D-A□-01 | |
Applicable standards |
International standards | IEC 61496- 1/2 (Type 4), ISO 13849- 1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) |
||
Japan | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) | |||
Europe | EN ISO 13849-1 (Category 4, PLe), EN 55011, EN 61000-6-2, EN IEC 63000 | |||
North America | ANSI/UL 61496-1/2 (Type 4),CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2 | |||
China | GB/T 4584 | |||
Applicable regulations and certifications | CE Marking (Machinery Directive, EMC Directive, RoHS Directive) , TÜV SÜD certification,TÜV SÜD NRTL certification (U.S.A., Canada), OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06, Korea KCs mark (Note 2) | |||
Operating range (Note 3) | Short mode: 0.2 to 7 m 0.656 to 22.966 ft Long mode: 0.8 to 12 m 2.625 to 39.370 ft (selectable by DIP switch) |
Short mode: 0.2 to 9 m 0.656 to 29.528 ft Long mode: 0.8 to 15 m 2.625 to 49.213 ft (selectable by DIP switch) |
||
Min. sensing object (Note 4) | ø14 mm ø0.551 in opaque object | ø25 mm ø0.984 in opaque object | ø45 mm ø1.772 in opaque object | |
Effective aperture angle | ±2.5° or less at a sensing range of 3 m 9.843 ft or longer (based on IEC 61496-2) | |||
Supply voltage | 24 V DC+20-30 % Ripple P-P 10 % or less (excluding voltage drop due to cable) (Note 5) | |||
Control outputs (OSSD 1, OSSD 2) |
PNP open-collector transistor / NPN open collector transistor (selectable) <PNP output selected> ・Maximum source current: 350 mA ・Applied voltage: Same as supply voltage (between control output and +V) ・Residual voltage: 2 V or less (source current 350 mA) (excluding voltage drop due to cable) ・Leakage current: 0.2 mA or less (including power OFF state) ・Maximum load capacity: 2.2 μF ・Load wiring resistance: 3 Ω or less <NPN output selected> ・Maximum sink current: 350 mA ・Applied voltage: Same as supply voltage (between control output and 0 V) ・Residual voltage: 2 V or less (sink current 350 mA) (excluding voltage drop due to cable) ・Leakage current: 0.2 mA or less (including power OFF state) ・Maximum load capacity: 2.2 μF ・Load wiring resistance: 3 Ω or less |
|||
Operation mode | ON when all beams are received, OFF when one or more beams are blocked (Also OFF when internal sensor error or synchronization signal error occurs) (Note 6) |
|||
Protection circuit | Incorporated | |||
Response time | OFF response: 10 ms or less (Not connected in series / parallel), 18 ms or less (Connected in series / parallel) (Note 7) ON response: 50 ms or less (Note 8) (Note 9) |
|||
Auxiliary output (AUX) (Non-safety output) |
PNP open-collector transistor / NPN open collector transistor (selectable) <PNP output selected> ・Maximum source current: 60 mA ・Applied voltage: Same as supply voltage (between auxiliary output and +V) ・Residual voltage: 2 V or less (source current 60 mA) (excluding voltage drop due to cable) ・Leakage current: 0.2 mA or less (including power OFF state) <NPN output selected> ・Maximum sink current: 60 mA ・Applied voltage: Same as supply voltage (between auxiliary output and 0 V) ・Residual voltage: 2 V or less (sink current 60 mA) (excluding voltage drop due to cable) ・Leakage current: 0.2 mA or less (including power OFF state) |
|||
Operation mode | Control output ON: OFF, Control output OFF: ON (Note 6) | |||
Protection circuit | Incorporated | |||
Response time | OFF response: 60 ms or less, ON response: 60 ms or less | |||
Synchronization method | Line synchronization / optical synchronization (selectable by DIP switch) | |||
Interference prevention function |
<Not connected in series/parallel> ・Line synchronization: 2 units or less (auto) ・Optical synchronization: 2 units or less (selectable by DIP switch) <Connected in series/parallel> ・Series connection: 5 units or less (total number of beam channels 256 or less) ・Parallel connection: 3 units or less (total number of beam channels 192 or less) (Note 6) ・Series / parallel connection mixed: 5 units or less (total number of beam channels 144 or less) (Note 6) |
|||
Test input function | Incorporated | |||
Interlock function | Incorporated [Manual reset / auto reset (selectable by wiring)] (8-core cable or 12-core cable) | |||
Lockout release function | Incorporated | |||
External device monitor function | Incorporated (8-core cable or 12-core cable) | |||
Application indicator function | Incorporated (only the receiver lights up when optical synchronization is used) | |||
Muting function | Incorporated (12-core cable) | |||
Override function | Incorporated (12-core cable) | |||
Power save function | Incorporated | |||
Optional functions (Note 10) (Excluding SF4D-□-01) |
Fixed blanking function, floating blanking function, interlock setting function, external device monitoring setting function, auxiliary output setting function, application indicator setting function, muting setting function, override setting function, protect function, I/O setting function | |||
Pollution degree | 3 | |||
Operating altitude | 2,000 m 6,561.68 ft or less (Note 11) | |||
Environmental resistance |
Degree of protection | IP67, IP65 (IEC), NEMA Type 13 (NEMA 250) | ||
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉ | |||
Ambient humidity | 30 to 85 % RH, Storage: 30 to 95 % RH | |||
Ambient illumination | Incandescent light: 5,000 ℓx or less at the light-receiving surface | |||
Dielectric strength voltage | 1,000 V AC for one minute, between all supply terminals connected together and enclosure | |||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure | |||
Vibration resistance | 10 to 55 Hz, 0.75 mm 0.030 in double amplitude in X, Y, and Z directions for two hours each Malfunction resistance 10 to 55 Hz, 0.75 mm 0.030 in double amplitude in X, Y, and Z directions twenty times each |
|||
Shock resistance | 300 m/s2 acceleration (30 G approx.) in X, Y, and Z directions three times each Malfunction resistance 100 m/s2 acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each |
|||
SFF (Safe Failure Fraction) | 99% | |||
HFT (Hardware Fault Tolerance) | 1 | |||
Subsystem type | Type B (IEC 61508-2) | |||
T1 (proof test interval) | 20 years | |||
Failure response time | Within response time (OFF response) | |||
Safety state | Control output (OSSD 1 / 2) OFF state | |||
Emitter element | Infrared LED (peak emission wavelength: 850 nm 0.034 mil) | |||
Material | Enclosure: Aluminum, Detection surface: Polycarbonate resin and stainless steel (SUS304), Upper cap / lower cap: Nylon | |||
Connecting method | By connector | |||
Cable extension | Total length of emitter / receiver can be extended up to 70 m 229.659 ft each using optional mating cable (including the length of cables for series connection) (Note 5) | |||
Accessories | SF4B-TR14 (test rod): 1 pc. | SF4B-TR25 (test rod): 1 pc. | - |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
2) | Except for SF4D-□-01, Korea KCs mark is acquired. |
3) | The operating range is the possible setting distance between the emitter and the receiver. |
4) | When the floating blanking function is used, the size of the minimum sensing object varies. For the detail, refer to the section on Safety distance. |
5) | In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline. |
6) | The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. Note that the setting cannot be changed when SF4D-□-01 is used. |
7) | For response times by number of beams, refer to the Control output (OSSD 1, OSSD 2) OFF response times. |
8) | Because the control output (OSSD 1, OSSD 2) must be OFF for at least 80 ms, the ON response will be delayed more than 50 ms when the light blocked time is less than 30 ms. |
9) | When optical synchronization is selected, if the beam axes of both the top end and bottom end are blocked, the ON response speed decreases by as much as 1 sec. |
10) | To use optional functions, the SF4D-TM1 (optional) and Configurator Safety Light Curtain setting software are required. Note that optional functions cannot be used when SF4D-□-01 is used. |
11) | Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
Number of sub-sensors |
Control output (OSSD 1, OSSD 2) source / sink current |
Power supply cable length Length of cable for series connection (Total cable length) |
Cable | |
---|---|---|---|---|
Power supply cable length |
Cable length for series connection |
|||
0 (No series connection) |
100 mA | 70 m 229.659 ft or less | - | - |
200 mA | ||||
350 mA | 10.5 m 34.449 ft or less | |||
1 | 100 mA | 50 m 164.042 ft or less | - | Cable length obtained by subtracting power supply cable length from total cable length |
200 mA | ||||
350 mA | 10.5 m 34.449 ft or less | |||
2 | 100 mA | 50 m 164.042 ft or less | - | |
200 mA | ||||
350 mA | 10.5 m 34.449 ft or less | |||
3 | 100 mA | 50 m 164.042 ft or less | - | |
200 mA | 40.5 m 132.874 ft or less | |||
350 mA | 10.5 m 34.449 ft or less | |||
4 | 100 mA | 25.5 m 83.661 ft or less | - | |
200 mA | 20.5 m 67.257 ft or less | |||
350 mA | 10.5 m 34.449 ft or less |
* Power supply cable: Cable consisting of the bottom cap cable (optional) and extension cable (optional)
OFF response time | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Main sensor |
Sub sensor | ||||||||||||
Number of units connected in series |
1 unit | 1 unit | 2 units | 3 units | 4 units | 0 unit | 0 unit | 1 unit | 1 unit | 2 units | 2 units | 3 units | |
Number of units connected in parallel |
0 unit | 0 unit | 0 unit | 0 unit | 1 unit | 2 units | 1 unit | 2 units | 1 unit | 2 units | 1 unit | ||
Total number of beams |
4 to 48 | 6ms | 10ms | 10ms | 12ms | 12ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms |
49 to 96 | 8ms | 10ms | 10ms | 12ms | 12ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | |
97 to 127 | 10ms | 12ms | 12ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | |
128 to 144 | - | 12ms | 12ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | 14ms | |
145 to 192 | - | 14ms | 14ms | 16ms | 16ms | 14ms | 14ms | - | - | - | - | - | |
193 to 256 | - | 16ms | 16ms | 18ms | 18ms | - | - | - | - | - | - | - |
・Example of series connection
5 units or fewer (Total number of beam channels must be 256 or less.)
|
・Example of combination of series connection and parallel connection
5 units or fewer (Total number of beam channels must be 144 or less.)
|
・ | When SF4D-□-01 is used, parallel connection or combination of series connection and parallel connection cannot be used. |
---|---|
・ | In the case of parallel connection or combination of series connection and parallel connection, it is necessary to change settings by using the SF4D-TM1 communication module (optional) and Configurator Safety Light Curtain setting software. |
For specifications of the control units, please see each product page.
>>"Safety Control Unit SF-C21"
>>"Exclusive Control Unit for Safety Light Curtain SF-C10"
Product name | IO-Link communication unit for safety light curtain SF4D series | |
---|---|---|
Model No. | SFD-WL3 | |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive) | |
Communication method |
Safety light curtain communication side |
RS-485 bidirectional communication (dedicated protocol) |
IO-Link communication side |
IO-Link specifications: Ver. 1.1 | |
Baud rate: COM3 (230.4 kbps) | ||
Data length: 18 bytes, process data (PD) | ||
Minimum cycle time: 1.5 ms | ||
Supply voltage |
Safety light curtain communication side |
24V DC +20-30 % Ripple P-P 10 % or less |
IO-Link communication side |
24V DC +20-25 % Ripple P-P 10 % or less | |
Current consumption |
Safety light curtain communication side |
15 mA or less |
IO-Link communication side |
30 mA or less | |
Functions | • IO-Link communication function • Safety light curtain setting data copy function (Note 2, 3, 4) |
|
Number of connectable units |
This product | 1 unit |
Safety light curtains in series connection |
Up to 5 units (total number of beam channels 256 or less) | |
Pollution degree / Excess voltage category | 3 / I | |
Operating altitude | 2,000 m 6561.68 ft or less (Note 5) | |
Environmental resistance |
Protection | IP64 (IEC) |
Ambient temperature | -10 to +55℃ 14 to 131℉ (No dew condensation or icing allowed), Storage: -25 to +60℃ -13 to 140℉ |
|
Ambient humidity | 30 to 85% RH, Storage: 30 to 95% RH | |
Dielectric strength voltage |
1,000 V AC for one min. between all supply terminals connected together and enclosure | |
Insulation resistance |
20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure | |
Vibration resistance |
10 to 55 Hz, 0.75 mm 0.030 in double amplitude in X, Y, and Z directions for two hours each Malfunction resistance 10 to 55 Hz, 0.75 mm 0.030 in double amplitude in X, Y, and Z directions twenty times each |
|
Shock resistance |
300 m/s2 acceleration (30 G approx.) in X, Y, and Z directions three times each Malfunction resistance 100 m/s2 acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each |
|
Material | Main unit case: PA66 (with glass) Base plate: SPCC + Plating Product model nameplate: Polyester External connection connector: Brass + Plating |
|
Connection method |
Safety light curtain communication side |
8-core cable for safety light curtain (optional) |
IO-Link communication side |
4-core cable with M12 connector (commercially available product) |
|
Weight | Net weight: 270 g approx., Gross weight: 340 kg approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
2) | This function is designed for use in maintenance and replacement of safety light curtain. If different setting information is written, the unit may not operate properly. |
3) | The internal memory (nonvolatile) of this product has a service life. Settings cannot be configured more than 100,000 times. |
4) | This function cannot be used unless the product is connected with the IO-Link master unit and IO-Link communication is used. |
5) | Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
6) | The product and IO-Link master unit must be connected with a cable of 0.3 mm2 or more. The total length of the cable must not exceed 20 m 65.62 ft. |
Model No. | SF4D-TM1 |
---|---|
Communication system | Safety light curtain side: RS-485 bilateral communication (dedicated protocol) PC side: USB |
Connection system | Safety light curtain side: Connector PC side: USB (Mini-B male) |
Protection | IP40 (IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (no dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉ |
Ambient humidity | 30 to 85% RH, Storage: 30 to 95% RH |
Usable altitude | 2,000 m 6,561.68 ft or lower (Note 2) |
Cable | 1.5 m 4.921 ft cable with connector (safety light curtain side) (Note 3) |
Weight | Net weight: 75 g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
2) | Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
3) | USB cable is not provided with the product. USB2.0 cable (A: Mini-B) must be prepared by the user. |
Model No. | SF-LAT-2N |
---|---|
Supply voltage | 3 V (LR6 battery x 2 pcs.) |
Battery | 1.5 V (LR6 battery) x 2 pcs. (replaceable)(Note 2) |
Battery lifetime | 30 hours approx. of continuous operation (LR6 battery, at +25 ℃ +77 ℉ ambient temperature) |
Light source | Red semiconductor laser: class 2 (IEC / JIS), Class II (FDA) (Max. output: 1 mW, Peak emission wavelength: 650 nm 0.026 mil)(Note 3) |
Spot diameter | 10 mm 0.394 in approx. (at 5 m 16.404 ft distance) |
Ambient temperature | 0 to +40 ℃ +32 to +104 ℉ (No dew condensation), Storage: 0 to +55 ℃ +32 to +131 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: ABS, Mounting part: Aluminum |
Weight | Net weight: 150 g approx. (without batteries) |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
2) | LR6 dry cell batteries are not provided with the product. Please purchase them separately. |
3) | As for FDA regulation, the product complies with 21 CFR 1040.10 and 1040.11 based on Laser Notice No. 50, dated June 24, 2007, issued by CDRH under the FDA. |
Model No. | RF-SFBH-□ | |
---|---|---|
Attenuation rate of operating range | With one corner mirror: Declined to 90 %, With two corner mirrors: Declined to 80 %, With three corner mirrors: Declined to 70 % (When used in combination with the SF4D series) | |
Environmental resistance |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +70 ℃ –13 to +158 ℉ |
Ambient humidity | 30 to 85 % RH, Storage: 30 to 95 % RH | |
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | |
Shock resistance | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | |
Material | Enclosure: Aluminum, Mounting bracket: Stainless steel, Mirror (rear surface mirror): Glass, Side cover: EPDM | |
Accessories | Intermediate supporting bracket: 1 set (RF-SFBH-40/48/56/64), 2 sets (RF-SFBH-72/80/88/96) |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
2) | The corner mirror has not received type examination by the Ministry of Health, Labour and Welfare; therefore, it cannot be used for presses or shearing machines (paper cutting machines) in Japan. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)