This Web site is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use.

  • The customer is responsible for ensuring the safety of the entire system and the compliance with the standards applicable in the country / region of use.

Machine designer, installer, employer and operator

  • The machine designer, installer, employer and operator are solely responsible to ensure that all applicable legal requirements relating to the installation and the use in any application are satisfied and all instructions for installation and maintenance contained in the instruction manual are followed.
  • Whether this device functions as intended to and systems including this device comply with safety regulations depends on the appropriateness of the application, installation, maintenance and operation. The machine designer, installer, employer and operator are solely responsible for these items.

  • This product has been developed / produced for industrial use only.
  • This product is an extremely low power radio device and complies with the Japanese Radio Act. There is no need to obtain a radio station license to use the product in Japan.
  • Do not use this product near equipment that emits strong electromagnetic waves.
  • If the power supply used for this device is shared by other devices, the device may be affected by noise emitted from other devices. Do not share the power supply used for this device with other devices.
  • The switch body of this product must be connected to a power supply unit and a safety device such as a safety controller. Power supply unit and safety controller must be purchased separately.
  • The power supply unit used for this device must satisfy the following requirements.
  • The power supply unit must be certified for use in your region.
  • The power supply unit must have the rated output voltage of 24 V DC +10 -20 % and the ripple (P-P) of 10 % or less.
  • The power supply with SELV (Secondary Extra Low Voltage) or PELV (Protective Extra Low Voltage) that comply with the RE Directive must be used. (When CE Marking is required)
  • The power supply must comply with Class 2 defined by UL508 or satisfy the output characteristics requirements of the limited voltage and current circuit.
  • The power supply unit must have reinforced insulation or double insulation between the primary circuit and secondary circuit.
  • When using a commercial switching regulator, the frame ground (F.G.) terminal must be connected to ground.
  • The power supply unit must have an output holding time of 20 ms or more.
  • If surges occur, take countermeasures such as connecting a surge absorber to the source of the surges.

Mounting

  • Do not install the switch body of this device on a movable door.
  • Mount the switch body carefully so that it does not come in contact with the movable door.
  • Mount the switch body in a location where it cannot be reached or it is hidden so that it cannot be easily disabled. Or, mount the switch body in such a way that it cannot be removed with ordinary tools.

 Correct mounting orientation 

Correct mounting orientation

 Incorrect mounting orientation 

Incorrect mounting orientation

Mutual Interference

When multiple devices are installed next to one another, mutual interference may occur and cause malfunctioning. When using them next to one another, provide a distance between one another as shown below.

 Switch body 
Mutual Interference Switch body
 Actuator 
Mutual Interference Actuator

Part description

 Switch body 

Part description Switch body
No. Name Function
Indicator Lights green When the actuator is detected
Lights red When the actuator is not detected
Blinks red • Lockout state, error occurrence
• When the teaching sequence was incorrect (only when using highcode models SG-P20□-□)
Blinks green When other switch bodies (standard unit, sub unit) in series connection do not detect actuators, when error occurs
Lights yellow
(Simultaneously light
green and red)
(Note)
After the power supply is turned ON, during self-diagnosis
Alternately blinking
red to yellow

(lights red, blinking green)
(Note)
When an unpaired actuator is detected (only when using highcode models SG-P20□-□)
Actuator detection surface When the actuator is brought near to the surface, the switch body detects the actuator.
Mounting hole Use M4 screws (length: 20 mm 0.787 in or more), flat washers and spring washers (not supplied with the product) to install the switch body to the equipment body or guard. The screws should be tightened with a torque of 1.2 N∙m.
Note : When you look at a lit LED on a visible type model through the actuator, the LED may sometimes appear green in some part and red in other part.

 Actuator 

Part description Actuator
No. Name Function
Switch body detection surface When the actuator is brought near to the switch body, the switch body detects the actuator.
Mounting hole Use M4 screws (length: 20 mm 0.787 in or more), flat washers and spring washers (not supplied with the product) to install the actuator to the door. The screws should be tightened with a torque of 1.2 N∙m.
Transmission part The light of the indicator is transmitted through the part.
About maintenance actuators (optional)

  • Using a maintenance actuator incorrectly can lead to an accident. Be sure to understand the operation of the system when using a maintenance actuator to use maintenance actuators correctly.

By directly mounting the maintenance actuator to the switch body while the door is open, it is possible to distinguish accidental opening of the door. Two types of maintenance actuators are available: overall maintenance type (SG-PK-M1) and individual maintenance type (SG-PK-M2 (Note)).
Note: In the case of the individual maintenance type SG-PK-M2, multiple units can be installed and used simultaneously.

Type Overall maintenance type Individual maintenance type
Model No. SG-PK-M1 SG-PK-M2
Ambient temperature 0 to +40 ℃ 0 to +104 ℉ (No dew condensation),
Storage: -25 to +65 ℃ -13 to +149 ℉
Ambient humidity 35 to 85 % RH, storage: 35 to 85 % RH
Vibration resistance 10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions
Shock resistance 300 m/s2 (30 G approx.),
3 times each in X, Y, and Z direction
Material POM (polyacetal)
Weight 7 g approx.

Overall maintenance type (SG-PK-M1) can be used only on standard switch bodies.
Individual maintenance type (SG-PK-M2) can be used on standard and sub switch bodies.
When maintenance actuators are used, redundant input monitoring (dual channel monitoring) of OSSD1and OSSD2 for the SG-P series by a safety controller, etc. cannot be used.
When using a maintenance actuator, be careful that the normal actuator will not be detected at the same time.
Determine whether to use the normal mode or maintenance mode according to the system.

Installation

 Installation on compact type unit 

 Installation on visible type unit 

Output operation and indicator operation

Operation differs between the overall maintenance type (SG‑PK‑M1) and individual maintenance type (SG‑PK‑M2). The output operation and indicator operation of the switch body when used with each maintenance actuator is as follows

 When using overall maintenance type actuator (SG-PK-M1) 
The SG-PK-M1 can only be used on standard switch bodies.

When using overall maintenance type actuator (SG-PK-M1)
Note: Individual maintenance type (SG-PK-M2) cannot be used when overall maintenance type is used.
Type Standard Sub1 Sub2 OSSD1 OSSD2
Actuator Detection Status Indicator Actuator Detection Status Indicator Actuator Detection Status Indicator
Overall Mainte-
nance
Mainte-
nance
Detection Yellow Normal Detection Yellow Normal Detection Yellow ON OFF
Detection Yellow Detection Yellow Not detected Red ON OFF
Detection Yellow Not detected Red Detection Yellow ON OFF
Not detected Red Detection Blinks
green
Detection Blinks
green
OFF OFF
  After
12 hours
(Note 1)
Detection Blinks
yellow/
red
Detection Blinks
yellow/
red
Detection Blinks
yellow/
red
OFF OFF

Notes:

1) Maintenance actuator can operate continuously for up to 12 hours. After 12 hours, OSSD1 turns OFF automatically and the indicator on the switch body blinks in yellow / red. To use the maintenance actuator again, detach the actuator and reinstall.
2) The indicator on the switch body blinks in yellow or red to indicate one of the two modes. For details, see the Instruction Manual of the SG-P series.

 When using individual maintenance type actuator (SG-PK-M2) 
The SG-PK-M2 can be used for standard and sub switch bodies.

Type Standard Sub1 Sub2 OSSD1 OSSD2
Actuator Detection Status Indicator Actuator Detection Status Indicator Actuator Detection Status Indicator
Indi-
vidual
Mainte-
nance
Normal Detection Yellow Mainte-
nance
Detection Yellow Normal Detection Yellow OFF ON
Not
detected
Red Detection Blinks
yellow/
red
Detection Blinks
yellow/
red
OFF OFF
Detection Blinks
green
Not
detected
Red Detection Blinks
green
OFF OFF
  After
12 hours
(Note)
Detection Blinks
yellow/
red
Detection Blinks
yellow/
red
Detection Blinks
yellow/
red
OFF OFF
Note : Maintenance actuator can operate continuously for up to 12 hours. After 12 hours, OSSD2 turns OFF automatically and the indicator on the switch body blinks in yellow / red. To use the maintenance actuator again, detach the actuator and reinstall.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)