Compact Type 4 Safety Beam Sensor ST4

I/O Circuit and Wiring diagrams

ST4-C11

In case of PNP output
・Set the output polarity selection switch to the PNP side.

In case of PNP output

Notes:

1) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) Emission halt input is for stopping emission when open, and emitting when short-circuited. If not using the test button, short-circuit T1 and T2.
KA, KB: Force-guided relay or magnetic contactor

In case of NPN output
・Set the output polarity selection switch to the NPN side.

In case of NPN output

Notes:

1) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) Emission halt input is for stopping emission when open, and emitting when short-circuited. If not using the test button, short-circuit T1 and T2.
KA, KB: Force-guided relay or magnetic contactor

Terminal arrangement diagram

Terminal Description
IL+ Interference prevention terminals
IL-
IU+ Interference prevention terminals
IU-
X1 Reset input terminals
(When X1 and X2 are connected: manual reset, and
when X1 and X3 are connected: auto reset)
X2
X3
T1 Emission halt input terminals
(Open: emission halt, Short-circuit: emission)
T2
AUX Negative logic of the control outputs
(OSSD1, OSSD2)
OSSD1 Control outputs (OSSD1, OSSD2)
OSSD2
A1 24V DC
A2 0V

ST4-C12EX

In case of PNP output
・Set the output polarity selection switch to the PNP side.

In case of PNP output
When using the normally open (NO) contact switch as a muting sensor, wire as shown in the figure below.

Notes:

1)

The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.

2) Use a momentary-type switch as the reset (RESET) button.
3) Emission halt input is for stopping emission when open, and emitting when short-circuited. If not using the test button, short-circuit T1 and T2.
KA, KB: Force-guided relay or magnetic contactor

In case of NPN output
・Set the output polarity selection switch to the NPN side.

In case of NPN output
When using the normally open (NO) contact switch as a muting sensor, wire as shown in the figure below.

Notes:

1)

The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.

2) Use a momentary-type switch as the reset (RESET) button.
3) Emission halt input is for stopping emission when open, and emitting when short-circuited. If not using the test button, short-circuit T1 and T2.
KA, KB: Force-guided relay or magnetic contactor

Terminal arrangement diagram

Terminal arrangement diagram

Terminal Description
S+ Muting input power supply (24 V)
S-A Muting input S-A [For NO (nomally open) contact or PNP output type sensor]
S-B Muting input S-B [For NO (nomally open) contact or NPN output type sensor]
S- Muting input power supply (0 V)
S+ Muting input power supply (24 V)
S-C Muting input S-C [For NO (nomally open) contact or PNP output type sensor]
S-D Muting input S-D [For NO (nomally open) contact or NPN output type sensor]
S- Muting input power supply (0 V)
S+ Muting input power supply (24 V)
S-E Muting input S-E [For NO (nomally open) contact or PNP output type sensor]
S-F Muting input S-F [For NO (nomally open) contact or NPN output type sensor]
S- Muting input power supply (0 V)
AUX1 Auxiliary output 1 (muting function)
AUX2 Auxiliary output 2 (override function)
AUX3 Auxiliary output 3 (muting lamp shutoff)
AUX4 Negative logic of the control outputs (OSSD1, OSSD2)
OSSD1 Control outputs (OSSD1, OSSD2)
OSSD2
L1 Muting lamp connecting terminal
L2
A1 24V DC
A2 0V
IL+ Interference prevention terminals
IL-
IU+ Interference prevention terminals
IU-
O1 Override input terminals
O2
X1 Reset input terminals
(When X1 and X2 are connected: manual reset, and
when X1 and X3 are connected: auto reset)
X2
X3
T1 Emission halt input terminals
(Open: emission halt, Short-circuit: emission)
T2

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)