Compact Type 4 Safety Beam Sensor ST4
I/O Circuit and Wiring diagrams
ST4-C11
In case of PNP output
・Set the output polarity selection switch to the PNP side. |
 |
|
Notes:
1) |
The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. |
2) |
Use a momentary-type switch as the reset (RESET) button. |
3) |
Emission halt input is for stopping emission when open, and emitting when short-circuited. If not using the test button, short-circuit T1 and T2. |
KA, KB: |
Force-guided relay or magnetic contactor |
In case of NPN output
・Set the output polarity selection switch to the NPN side. |
 |
|
Notes:
1) |
The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. |
2) |
Use a momentary-type switch as the reset (RESET) button. |
3) |
Emission halt input is for stopping emission when open, and emitting when short-circuited. If not using the test button, short-circuit T1 and T2. |
KA, KB: |
Force-guided relay or magnetic contactor |
Terminal arrangement diagram
|
Terminal |
Description |
IL+ |
Interference prevention terminals |
IL- |
IU+ |
Interference prevention terminals |
IU- |
X1 |
Reset input terminals (When X1 and X2 are connected: manual reset, and when X1 and X3 are connected: auto reset) |
X2 |
X3 |
T1 |
Emission halt input terminals (Open: emission halt, Short-circuit: emission) |
T2 |
AUX |
Negative logic of the control outputs (OSSD1, OSSD2) |
OSSD1 |
Control outputs (OSSD1, OSSD2) |
OSSD2 |
A1 |
24V DC |
A2 |
0V |
|
ST4-C12EX
In case of PNP output
・Set the output polarity selection switch to the PNP side. |
 |
|
Notes:
1) |
The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. |
2) |
Use a momentary-type switch as the reset (RESET) button. |
3) |
Emission halt input is for stopping emission when open, and emitting when short-circuited. If not using the test button, short-circuit T1 and T2. |
KA, KB: |
Force-guided relay or magnetic contactor |
In case of NPN output
・Set the output polarity selection switch to the NPN side. |
 |
|
Notes:
1) |
The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. |
2) |
Use a momentary-type switch as the reset (RESET) button. |
3) |
Emission halt input is for stopping emission when open, and emitting when short-circuited. If not using the test button, short-circuit T1 and T2. |
KA, KB: |
Force-guided relay or magnetic contactor |
Terminal arrangement diagram
|
Terminal |
Description |
S+ |
Muting input power supply (24 V) |
S-A |
Muting input S-A [For NO (nomally open) contact or PNP output type sensor] |
S-B |
Muting input S-B [For NO (nomally open) contact or NPN output type sensor] |
S- |
Muting input power supply (0 V) |
S+ |
Muting input power supply (24 V) |
S-C |
Muting input S-C [For NO (nomally open) contact or PNP output type sensor] |
S-D |
Muting input S-D [For NO (nomally open) contact or NPN output type sensor] |
S- |
Muting input power supply (0 V) |
S+ |
Muting input power supply (24 V) |
S-E |
Muting input S-E [For NO (nomally open) contact or PNP output type sensor] |
S-F |
Muting input S-F [For NO (nomally open) contact or NPN output type sensor] |
S- |
Muting input power supply (0 V) |
AUX1 |
Auxiliary output 1 (muting function) |
AUX2 |
Auxiliary output 2 (override function) |
AUX3 |
Auxiliary output 3 (muting lamp shutoff) |
AUX4 |
Negative logic of the control outputs (OSSD1, OSSD2) |
OSSD1 |
Control outputs (OSSD1, OSSD2) |
OSSD2 |
L1 |
Muting lamp connecting terminal |
L2 |
A1 |
24V DC |
A2 |
0V |
IL+ |
Interference prevention terminals |
IL- |
IU+ |
Interference prevention terminals |
IU- |
O1 |
Override input terminals |
O2 |
X1 |
Reset input terminals (When X1 and X2 are connected: manual reset, and when X1 and X3 are connected: auto reset) |
X2 |
X3 |
T1 |
Emission halt input terminals (Open: emission halt, Short-circuit: emission) |
T2 |
|
Return to top