AUTOMATION
CONTROLS

Search
Discontinued
Products



Bench Top Ionizer Cleaning Box EC-B

Specifications

Type 200 mm 7.874 in width type 400 mm 15.748 in width type
Model No. EC-B01-EX EC-B02-EX
Charge removal time
(±1,000 V → ±100 V)
0.5 sec. approx. or less (Note 2)
Ion balance ±10 V or less
Applicable fluid Air (dried clean air)
Supplied air flow Max. 300 ℓ/min. (ANR) or less Max. 500 ℓ/min. (ANR) or less
Air pressure range 0.05 to 0.50 MPa
Power supply voltage Accessory AC adapter (Note 3) INPUT: 100 to 240 V AC ±10 % 50/60 Hz
(OUTPUT: 24 V DC)
Power consumption 80 VA or less 90 VA or less
Dust removal operation output Photocoupler output / Universal
・Max sink current: 100 mA
・Residual voltage: 2.5 V or less (at sink current of 100 mA or less)
  Output operation During dust removal operation: ON, during standby: OFF
External input 0 V short-circuit: Input received
Timer mode 2 sec. / 5 sec. / 10 sec. / synchronized with sensor or with external input selectable by switch
Pulse air mode Pulse 1 (long) / Pulse 2 (short) / OFF (continuous) selectable by switch
Ambient temperature 0 to +40 ℃ +32 to +104 ℉
Ambient humidity 35 % to 65 % RH (No dew condensation)
Enclosure earthing method C (capacitor) earth
Net weight Main body: 6.5 kg approx. Main body: 13 kg approx.
Accessories AC adapter: 1pc., Filter: 1pc., Protective mesh: 1pc.

Notes:
1) Where measurement conditions have not been specified precisely,
    the conditions used were an ambient temperature of +20℃ +68℉.
2) Typical value at 100 mm 3.937 in from the front of air outlet at an applied air pressure of 0.50 MPa.
3) Please prepare an AC cable separately as it is needed. The following cables are available as optionals:
    CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)