Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Static Control Devices > Static Control Devices > Electrostatic Sensor EF-S1 > Specifications
|
Model No. | EF-S1HS |
---|---|
Applicable controller | EF-S1C |
Measurement range (Measurement range) (Note 2, 3, 4) |
8.0 to 20.5 mm 0.315 to 0.807 in (±1 kV range mode) 21.0 to 100 mm 0.827 to 3.937 in (±2 kV range mode) |
Power indicator | Green LED |
Ambient temperature | 0 to +40 ℃ +0 to +104 ℉ (No dew condensation), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Ambient humidity | 35 to 65 % RH, Storage: 35 to 85 % RH |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Material | Enclosure: Heat resistant ABS, Measuring part cover: Stainless steel (SUS304) |
Cable | 0.09 mm2, 3-core shielded cable, 5 m 16.404 ft long (with controller connector) (Note 5) |
Weight | Net weight: 90 g approx., Gross weight: 130 g approx. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Set the distance between the sensor head and the sensing object by using the controller before use.
3) The measurement range mode is switched automatically when the measurement range setting is changed at the controller.
4) Measurement areas will vary depending on the measurement distances.
5) Cable cannot be extended.
Model No. | EF-S1C | |
---|---|---|
Applicable sensor head | EF-S1HS | |
Supply voltage | 24V DC ± 10% | |
Current consumption | Normal operation: 50 mA or less, ECO mode: 40 mA or less | |
Display range (Measurement range) (Note 2) |
-1,000 to 1,000 (±1 kV range mode) -1,999 to 1,999 (±2 kV range mode) |
|
Repeatability | ±0.3 % F.S.(Note 3) | |
Linearity | ±0.5 % F.S. (Note 3, 4, 6) | |
Temperature characteristics | 0.05 % F.S./℃ (Note 3, 5) | |
Judgment outputs (OUT 1, OUT 2) |
NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 30 V DC or less (between judgment output and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current) |
|
Response time | 10 ms, 20 ms (STD), 100 ms, 200 ms, 400 ms, 800 ms switching method | |
Output operation | OUT1: +potential measurement output or window comparator output OUT2: -potential measurement output or error output |
|
Short-circuit protection | Incorporated | |
Analog output (Note 6) | Analog voltage ・Output voltage: 1 to 5 V ・Output impedance: 100 Ω approx. |
|
Response time | 20 ms, 30 ms (STD), 110 ms, 210 ms, 410 ms, 810 ms switching method | |
Timing input / 0-adjust input | NPN non-contact input ・Signal condition High: +V or open, Low: 0 to +2 V (source current 0.5 mA or less) ・Input impedance: 10 kΩ approx. |
|
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ |
|
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |
Material | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Mode key: Acrylic, Jog switch: Heat-resistant ABS | |
Cable | 0.2 mm2 6-core cabtyre cable, 2 m 6.562 ft long | |
Cable extension (Note 7) | Extension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable. | |
Weight | Net weight: 65 g approx., Gross weight: 110 g approx. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) The display range (measurement range) is switched automatically when the measurement distance setting is changed at the controller.
3) F.S. is 2,000 V (-1,000 V to 1,000 V) for the ±1 kV range mode and 4,000 V (-2,000 V to 2,000 V) for the ±2 kV range mode.
4) The values given are for when the measured potential is ±200 V or less in the ±1 kV range mode and ±400 V or less in the ±2 kV range mode.
If the measured potentials are outside these values, the values will be equal to the displayed values ±5 %.
5) The values given are for when the measured potential is ±200 V or less in the ±1 kV range mode and ±400 V or less in the ±2 kV range mode.
If the measured potentials are outside these values, the values will be 0.5 %/℃ of the displayed values.
6) In order to satisfy the linearity specifications for the analog output, do not use the judgment output.
7) This product is CE compliant and complies with EMC directives. EN 61000-6-2 is the applicable standard that covers immunities relating to use of this
product, but in order to comply with this standard, the following conditions must be satisfied.
- The controller must be connected to the power supply at a distance of less than 10 m 32.808 ft.
- Install the ferrite core (accessory) to the cable approximately 30 mm 1.181 in away from the sensor head (EF-S1HS).