AUTOMATION
CONTROLS

Search
Discontinued
Products



Fan Type Ionizer ER-F

Specifications

Type Standard fan type Low-volume fan type
Model No. ER-F12A ER-F12SA
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Charge removal time
(±1,000 V → ±100 V)
1 sec. approx. (Note 2) 1.5 sec. approx. (Note 2)
Ion balance ±10 V or less (Note 3)
Power supply voltage 24 V DC ±10%
Power consumption 700 mA or less 400 mA or less
Discharge method High-frequency AC method
Discharge output voltage ± 2 kV approx.
Main functions Error output, Discharge halt input
Indicators Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green)
Ozone generation amount 0.04 ppm or less (Note 2)
Ambient temperature 0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed),
Storage: –10℃ to +65℃ +14℉ to +149℉
Ambient humidity 35% RH to 65% RH (No dew condensation allowed),
Storage: 35% RH to 65% RH
Grounding method C (capacitor) grounding
Material Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC
Weight New weight : 790 g approx.
Accessories Straight louver: 1 pc. (Note 4), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc.

Notes:

1) If not specified, the ambient temperature for measurement is +20℃ +68℉.
2) Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
3) Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
4) The discharge needle unit is loaded on the straight louver before shipment.

Discontinued Products

Type Standard fan type Low-volume fan type
Model No. ER-F12 ER-F12S
Charge removal time
(±1,000 V → ±100 V)
1 sec. approx. (Note 2) 1.5 sec. approx. (Note 2)
Ion balance ±10 V or less (Note 3)
Power supply voltage 24 V DC ±10%
Power consumption 700 mA or less 400 mA or less
Discharge method High-frequency AC method
Discharge output voltage ±2 kV approx.
Max. fan speed 5.3 m/s (Note 3) 4.0 m/s (Note 3)
Max. fan volume 3.68 m3/min. 2.50 m3/min.
Error output NPN open-collector transistor
• Max sink current: 50 mA
• Applied voltage: 30 V DC or less (between output terminal and 0 V)
• Residual voltage: 1 V or less (at input current of 50 mA)
  Output operation OFF when discharge error or fan error detected
Normally ON
  Short-circuit protection Incorporated
Discharge halt input Discharge halt: Short-circuited to 0 V
Discharge (operation start): Open
Indicators Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green)
Ozone generation amount 0.04 ppm or less (Note 2)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: –10 to +65 ℃ +14 to +149 ℉
Ambient humidity 35 to 65% RH (No dew condensation), Storage: 35 to 65% RH
Grounding method C (capacitor) grounding
Material Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC
Weight 4 Main unit: 790 g approx.
Accessories Straight louver: 1 pc. (Note 4), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc.

Notes:
1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Typical value at 200 mm 7.874 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
3) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
4) The discharge needle unit is loaded on the straight louver before shipment.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)