Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Static Control Devices > Static Control Devices > Fan Type Ionizer ER-F > Specifications
Partly Order Discontinued
|
|
Type | Standard fan type | Low-volume fan type | |
---|---|---|---|
Model No. | ER-F12A | ER-F12SA | |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | ||
Charge removal time (±1,000 V → ±100 V) |
1 sec. approx. (Note 2) | 1.5 sec. approx. (Note 2) | |
Ion balance | ±10 V or less (Note 3) | ||
Power supply voltage | 24 V DC ±10% | ||
Power consumption | 700 mA or less | 400 mA or less | |
Discharge method | High-frequency AC method | ||
Discharge output voltage | ± 2 kV approx. | ||
Main functions | Error output, Discharge halt input | ||
Indicators | Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green) | ||
Ozone generation amount | 0.04 ppm or less (Note 2) | ||
Ambient temperature | 0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed), Storage: –10℃ to +65℃ +14℉ to +149℉ |
||
Ambient humidity | 35% RH to 65% RH (No dew condensation allowed), Storage: 35% RH to 65% RH |
||
Grounding method | C (capacitor) grounding | ||
Material | Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC | ||
Weight | New weight : 790 g approx. | ||
Accessories | Straight louver: 1 pc. (Note 4), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc. |
Notes:
1) | If not specified, the ambient temperature for measurement is +20℃ +68℉. |
---|---|
2) | Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. |
3) | Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. |
4) | The discharge needle unit is loaded on the straight louver before shipment. |
Type | Standard fan type | Low-volume fan type | |
---|---|---|---|
Model No. | ER-F12 | ER-F12S | |
Charge removal time (±1,000 V → ±100 V) |
1 sec. approx. (Note 2) | 1.5 sec. approx. (Note 2) | |
Ion balance | ±10 V or less (Note 3) | ||
Power supply voltage | 24 V DC ±10% | ||
Power consumption | 700 mA or less | 400 mA or less | |
Discharge method | High-frequency AC method | ||
Discharge output voltage | ±2 kV approx. | ||
Max. fan speed | 5.3 m/s (Note 3) | 4.0 m/s (Note 3) | |
Max. fan volume | 3.68 m3/min. | 2.50 m3/min. | |
Error output | NPN open-collector transistor • Max sink current: 50 mA • Applied voltage: 30 V DC or less (between output terminal and 0 V) • Residual voltage: 1 V or less (at input current of 50 mA) |
||
Output operation | OFF when discharge error or fan error detected Normally ON |
||
Short-circuit protection | Incorporated | ||
Discharge halt input | Discharge halt: Short-circuited to 0 V Discharge (operation start): Open |
||
Indicators | Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green) | ||
Ozone generation amount | 0.04 ppm or less (Note 2) | ||
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: –10 to +65 ℃ +14 to +149 ℉ | ||
Ambient humidity | 35 to 65% RH (No dew condensation), Storage: 35 to 65% RH | ||
Grounding method | C (capacitor) grounding | ||
Material | Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC | ||
Weight | 4 Main unit: 790 g approx. | ||
Accessories | Straight louver: 1 pc. (Note 4), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc. |
Notes:
1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Typical value at 200 mm 7.874 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
3) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
4) The discharge needle unit is loaded on the straight louver before shipment.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)