MINAS A5 Family(Discontinued Products)

System Configuration

Overall Wiring

[Connector type (100/200 V: A-frame to E-frame)]

Caution
Apply adequate tightening torque to the product mounting screw by taking into consideration strength of the screw and the
characteristics of material to which the product is installed. Overtightening can damage the screw and/or material;
undertightening can result in loosening.
Example) Steel screw (M5) into steel section: 2.7 N·m to 3.3 N·m.

 

[Connector type (400 V: D, E-frame)]

Note
Initial setup of rotational direction: positive = CCW and negative = CW.
Pay an extra attention.

 

Driver and List of Applicable Peripheral Equipments

Driver Applicable
motor
Voltage
*1
Rated
output
Required
Power
(at the rated load)
Circuit
breaker
(rated
current)
Noise
filter
(Single phase/
3-phase)
Surge
absorber
(Single phase/3-phase)
Noise filter for signal Rated
operating
current of
magnetic
(contactor Contact configuration)*2
Diameter and
withstand
voltage of
main circuit
cable
Crimp
terminal for
main circuit
terminal
block
*4
Diameter and
withstand
voltage of
control power
supply cable
Crimp
terminal
for control
power
supply
terminal
block
Diameter and
withstand
voltage of
motor cable
*5
Diameter
and
withstand
voltage of
brake cable
MADH
MADK
MSMD
MSME
MHMD
Single
phase,
100 V
50 W
to 100 W
approx.
0.4 kVA
10 A DV0P4170 DV0P4190 DV0P1460 20 A
(3P+1a)
0.75 mm2/
AWG18
600 VAC
or more
Connection to exclusive connector 0.75 mm2/
AWG18
600 VAC
or more
Connection to exclusive connector 0.75 mm2/
AWG18
600 VAC
or more
0.28 mm2
to
0.75 mm2/
AWG22
to
AWG18
100 VAC
or more
Single/
3-phase,
200 V
50 W
to 200 W
approx.
0.5 kVA
DV0P4170/
DV0PM20042
DV0P4190/
DV0P1450
MBDH
MBDK
MSMD
MSME
MHMD
Single
100 V
200 W approx.
0.5 kVA
DV0P4170 DV0P4190
Single/
3-phase,
200 V
400 W approx.
0.9 kVA
DV0P4170/
DV0PM20042
DV0P4190/
DV0P1450
MCDH
MCDK
MSMD
MSME
MHMD
Single
100 V
400 W approx.
0.9 kVA
DV0PM20042 DV0P4190
Single/
3-phase,
200 V
750 W approx.
1.3 kVA
15 A DV0P4190/
DV0P1450
MDDH
MDDK
MDME Single/
3-phase,
200 V
1.0 kW approx.
1.8 kVA
DV0P4220 30 A
(3P+1a)
2.0 mm2/
AWG14
600 VAC
or more
2.0 mm2/
AWG14
600 VAC
or more
0.75 mm2/
AWG18
100 VAC
or more
MHME
MGME 0.9 kW approx.
1.8 kVA
20 A
MSME 1.0 kW approx.
1.8 kVA
MHME 1.5 kW approx.
2.3 kVA
MDME
MFME
MSME
MDME 3-phase,
400 V
400 W approx.
0.9 kVA
10 A FN258L-16-07
(Recommended component )
DV0PM20050 20 A
(3P+1a)
0.52 mm2/
AWG20
100 VAC
or more
MDME 600 W approx.
1.2 kVA
MSME 750 W approx.
1.6 kVA
MSME 1.0 kW approx.
1.8 kVA
MDME
MHME
MGME 0.9 kW
MSME 1.5 kW approx.
2.3 kVA
MDME
MFME
MHME
MEDH
MEDK
MDME 3-phase,
200 V
2.0 kW approx.
3.3 kVA
30 A DV0PM20043 DV0P1450 DV0P1460
RJ8035
(Recommended component )
*6
60 A
(3P+1a)
0.75 mm2/
AWG18
600 VAC
or more
MSME
MHME
MFME 2.5 kW approx.
3.8 kVA
MSME 3-phase,
400 V
2.0 kW approx.
3.3 kVA
15 A FN258L-16-07
(Recommended component )
DV0PM20050 DV0P1460 30 A
(3P+1a)
0.52 mm2/
AWG20
100 VAC
or more
MDME
MHME
MFME 2.5 kW approx.
3.8 kVA
MFDH
MFDK
MGME 3-phase,
200 V
2.0 kW approx.
3.8 kVA
50 A DV0P3410 DV0P1450 DV0P1460
RJ8035
(Recommended component )
*6
60 A
(3P+1a)
3.5 mm2/
AWG12
600 VAC
or more

Terminal
block
M5
0.75 mm2/
AWG18
600 VAC
or more

Terminal
block
M5
3.5 mm2/
AWG12
600 VAC
or more
MDME 3.0 kW approx.
4.5 kVA
MHME
MSME
MGME
MDME 4.0 kW approx.
6.0 kVA
100 A
(3P+1a)
MHME
MSME
MFME 4.5 kW approx.
6.8 kVA
MGME approx.
7.5 kVA
MDME 5.0 kW
MHME
MSME
MGME 3-phase,
400 V
2.0 kW approx.
3.8 kVA
30 A FN258L-30-07
(Recommended component )
DV0PM20050 DV0P1460 60 A
(3P+1a)

Terminal
block
M4
0.75 mm2/
AWG18
100 VAC
or more

Terminal
block
M3
MSME 3.0 kW approx.
4.5 kVA
MDME
MGME
MHME
MSME 4.0 kW approx.
6.0 kVA
MDME
MHME
MFME 4.5 kW approx.
6.8 kVA
MGME approx.
7.5 kVA
MSME 5.0 kW
MDME
MHME
MGDH
MGDK
MDME 3-phase,
200 V
7.5 kW approx.
11 kVA
60 A FS5559-60-34
(Recommended component )
DV0P1450 DV0P1460
RJ8095
Recommended ( component )
T400-61D
(Recommended component )
*6
100 A
(3P+1a)
5.3 mm2/
AWG10
600 VAC
or more

Terminal
block
M5
0.75 mm2/
AWG18
600 VAC
or more

Terminal
block
M5
13.3 mm2/
AWG6
600 VAC
or more
MGME 6.0 kW approx.
9.0 kVA
MHME 7.5 kW approx.
11 kVA
MDME 3-phase,
400 V
7.5 kW approx.
11 kVA
30 A FN258-42-07
or
FN258-42-33
(Recommended component )
DV0PM20050 60 A
(3P+1a)
0.75 mm2/
AWG18
100 VAC
or more
MGME 6.0 kW approx.
9.0 kVA
MHME 7.5 kW approx.
11 kVA
MHDH
MHDK
MDME 3-phase,
200 V
11 kW approx.
17 kVA
100 A FS5559-80-34
(Recommended component )
DV0P1450 150 A
(3P+1a)
13.3 mm2/
AWG6
600 VAC
or more
*3

Terminal
block
M6
0.75 mm2/
AWG18
600 VAC
or more

Terminal
block
M4
15 kW approx.
22 kVA
125 A 21.1 mm2/
AWG4
600 VAC
or more
3-phase,
400 V
11 kW approx.
17 kVA
50 A FN258-42-07
or
FN258-42-33
(Recommended component )
DV0PM20050 100 A
(3P+1a)
0.75 mm2/
AWG18
100 VAC
or more
13.3 mm2/
AWG6
600 VAC
or more
15 kW approx.
22 kVA
60 A 21.1 mm2/
AWG4
600 VAC
or more

*1 Select peripheral equipments for single/3phase common specification according to the power source.
*2 For the external dynamic brake resistor, use the magnetic contactor with the same rating as that for the main circuit.
*3 When use the external regenerative resistor of the option (DV0PM20058, DV0PM20059), use the cable with the same diameter as the main circuit cable.
*4 For the ground screw, use the same crimp terminal as that for the main circuit terminal block.
*5 The diameter of the ground cable and the external dynamic brake resistor cable must be equal to, or larger than that of the motor cable.
The motor cable is a shield cable, which conforms to the EC Directives and UL Standards. (G, H-frame only)
*6 Use thses products to suit an international standard.

●About circuit breaker and magnetic contactor
To comply to EC Directives, install a circuit breaker between the power and the noise filter without

fail, and the circuit breaker should conform to IEC Standards and UL recognized (Listed and marked).


Suitable for use on a circuit capable of delivering not more than 5000 Arms symmetrical amperes, below the maximum input voltage of the product.
If the short-circuit current of the power supply exceeds this value, install a current limit device (current limiting fuse, current limiting circuit breaker, transformer, etc.) to limit the short-circuit current.


<Remarks>
・Select a circuit breaker and noise filter which match to the capacity of power supply (including a load condition).

● Terminal block and protective earth terminals
・ Use a copper conductor cables with temperature rating of 75 ℃ or higher.
・ Use the attached exclusive connector for A-frame to E-frame, and maintain the peeled off length of 8 mm to 9 mm.

■Fastening torque list (Terminal block screw/Terminal cover fastening screw)

Driver Terminal block screw Terminal cover fastening
screw
Frame Terminal name Nominal
size
Fastening
torque
(N・m)
Nominal
size
Fastening
torque
(N・m)
F(200 V) L1, L2, L3, L1C, L2C, B1, B2, B3, NC, U, V, W M5 1.0 to 1.7 M3 0.19 to 0.21
F(400 V) 24V、0V M3 0.4 to 0.6
L1, L2, L3, B1, B2, B3, NC, U, V, W M4 0.7 to 1.0
G L1C, L2C, 24 V, 0 V, DB1, DB2, DB3, DB4, NC M5 1.0 to 1.7
L1, L2, L3, B1, B2, NC, U, V, W M5 2.0 to 2.4 M3 0.3 to 0.5
H L1C, L2C, 24 V, 0 V, DB1, DB2 M4 0.7 to 1.0 M5 2.0 to 2.5
L1, L2, L3, B1, B2, NC, U, V, W M6 2.2 to 2.5

■Fastening torque list (Ground terminal screw/Connector to host controller [X4])

Driver frame Ground screw Connector to host
controller (X4)
Nominal
size
Fastening
torque
(N・m)
Nominal
size
Fastening
torque
(N・m)
A to E M4 0.7 to 0.8 M2.6 0.2±0.05
G M5 1.4 to 1.6
H M6 2.4 to 2.6

[Caution]
・ Applying fastening torque larger than the maximum value may result in damage to the product.
・ Do not turn on power without tightening all terminal block screws properly, otherwise, loose contacts may generate heat (smoking, firing).
[Remarks]
・ To check for looseness, conduct periodic inspection of fastening torque once a year.