AUTOMATION
CONTROLS

Search
Discontinued
Products



LS-501-C2 | Amplifier-separated Type Digital Laser Sensor LS-500


Amplifier-separated Type Digital Laser Sensor LS-500

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


Product Number LS-501-C2
Part Number LS-501-C2
Product Amplifier-separated Type Digital Laser Sensor
Details Amplifiers(Cable type)
Product name Amplifier-separated Type Digital Laser Sensor LS-500

As of April 19, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number LS-501-C2
Part Number LS-501-C2
Regulatory compliance EMC Directive, RoHS Directive
Operation indicator Orange LED (lights up when sensing output 1 or sensing output 2 is ON)
Protection IP40(IEC)
Ambient temperature -10 to +55degrees + 14 to 131 degrees Fahrenheit (If 4 to 7 units are mounted close together, -10 to +50 degrees +14 to +122 degrees Fahrenheit ; if 8 to 12 units are mounted close together, -10 to +45 degrees +14 to +113 degrees Fahrenheit )(No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2 in X, Y, and Z direction for 2 hours each.
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Material Enclosure: Polycarbonate
Cover: Polycarbonate
Switch: Polyacetal
Cable 0.2mm2 6-core cabtyre cable, 2 m 6.562 ft long
Weight Net weight: 75 g approx.
Gross weight: 110 g approx.
Accessory FX-MB1 (Amplifier protective seal): 1 set
Supply voltage 12 to 24 V DC +10-15% Ripple P-P 10 % or less
Power consumption Normal operation: 1,200 mW or less (Current consumption 50 mA or less at 24 V supply voltage,excluding monitor current output)
ECO mode: 980 mW or less (Current consumption 40 mA or less at 24 V supply voltage,excluding monitor current output)
Sensing outputs (Sensing output 1, 2) NPN open-collector transistor
・Maximum sink current: 50 mA (Note:25 mA if 5 or more amplifier are connected in cascade (excluding cable extension).)
・Applied voltage: 30 V DC or less (between output and 0 V)
・Residual voltage: 2 V or less (at max. sink current)
(Note:Select either sensing output 2 or external input as the connector type.)
Sensing outputs (Sensing output 1, 2):Output operation Selectable either Light-ON or Dark-ON
Sensing outputs (Sensing output 1, 2):Short-circuit protection Incorporated
Sensing output setting:Sensing output 1 Normal mode, differential mode, hysteresis mode, window comparator mode, selectable
Sensing output setting:Sensing output 2 Normal mode, differential mode, hysteresis mode, self-diagnostic output mode, answer-back output mode, selectable
(Note:Select either sensing output 2 or external input.)
Response time H-SP: 60 micro s or less, FAST: 150 micro s or less, STD: 250 micro s or less, LONG: 500 micro s or less, U-LG: 5 ms or less, HYPR: 24 ms or less selectable
Monitor current output Output current: Approx. 4 to 20 mA (H-SP, FAST, STD: at 0 to 4,000 indication)
Response time: 2 ms or less
Zero point: 4 mA plus or minus 1 % F.S.
Span: 16 mA plus or minus 5 % F.S.
Linearity: plus or minus 3 % F.S.
Load resistance: 0 to 250 Ohm
External input NPN non-contact input
- Signal condition High: +8 V to +V DC or open, Low: 0 to +2 V DC (source current 0.5 mA or less)
- Input impedance: 10 kOhm approx.(Note:Select either sensing output 2 or external input.)
External input function Laser emission halt / teaching (full-auto teaching, limit teaching, 2 point teaching) / logic operation setting / copy lock /display adjustment / data bank load / data bank save, selectable
Laser emission indicator Green LED (lights up during laser emission)
Output select indicator Yellow LED (lights up when output is selected)
Digital display 8-digit 7-segment digital display (4-digit green LED + 4-digit red LED), MODE indicator (Yellow LED): L/D, CUST, PRO
Incident light indication range H-SP/FAST/STD: 0 to 4,000
LONG/U-LG/HYPR: 0 to 9,999
Sensitivity setting 2-level teaching / limit teaching / full auto teaching / manual adjustment
Logical operation Between sensing output 1 and calculation target: Disabled / and / or / xor, selectable
Calculation target: Sensing output 2 / adjacent upstream amplifier (sensing output 1) / external input, selectable
Timer function
OFF-delay timer, ON-delay timer, ONE-SHOT timer, ON / OFF-delay timer, ON-delay / ONE-SHOT timer,
switchable either effective of ineffective, with variable timer period

OFF-delay timer, ON-delay timer, ONE-SHOT timer,
switchable either effective of ineffective, with variable timer period
Timer function:Time Timer range '' ms'': 0.5 ms approx., 1 to 9,999 ms approx., in approx. 1 ms intervals
Timer range '' sec'': 0.5 sec. approx., 1 to 32 sec. approx., in approx. 1 sec. intervals
Timer range '' 1/10 ms'': 0.05 ms approx., 0.1 to 999.9 ms approx., in approx. 0.1 ms intervals, Set separately for each output.
Automatic interference prevention function Incorporated
(Note:Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR)
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3mm2, or more, cable.

Return to top

Accessories (Option)

Communication Unit for Open Network SC-GU3
Product Number SC-GU3-01
Part Number SC-GU3-01
Product Commnunication Unit for Open Network
Details Communication unit for CC-Link
Product name Communication Unit for Open Network SC-GU3

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)