Product Number LS-H91-Y
Part Number LS-H91-Y
Product Digital Laser Sensor
Details Sensor head (Coaxial retroreflective type)
Product name Digital Laser Sensor LS-400

As of April 16, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number LS-H91-Y
Part Number LS-H91-Y
Applicable amplifiers LS-401(P), LS-401(P)-C2, LS-403
Sensing range:U-LG mode 0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Sensing range:STD mode 0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Sensing range:FAST mode 0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Sensing range:H-SP mode 0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Operation indicator Orange LED (lights up when the amplifier output is ON)
Laser emission indicator Green LED (lights up during laser emission)
Spot-shape adjuster -
Protection IP40 (IEC)
Ambient temperature -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 lx or less at the light-receiving face
Voltage withstandability 1,000 V AC for one min.
between all supply terminals connected together and enclosure
Insulation resistance 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2 in X, Y, and Z direction for 2 hours each.
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Emitting element:IEC / EN / JIS / GB / KC standards conforming type Red semiconductor laser,
Class 2 (IEC / EN / JIS / GB / KC)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
Emitting element:FDA / IEC / EN / JIS standards conforming type Red semiconductor laser,
Class 2 (FDA / IEC / EN / JIS)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 56.
Material Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
Cable 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached)
(Note) Cable cannot be extended.
Weight Net weight: 30 g approx
Gross weight: 45 g approx
Accessory Warning label: 1 set
(Labels are written in Japanese, English and Chinese for compliance with various standards.)

Return to top

Accessories (Option)

Cable
Product Number CN-72-C1
Part Number CN-72-C1
Product Quick-connection cables
Details Sub cable(2-core)
Product name Cable
Cable
Product Number CN-72-C2
Part Number CN-72-C2
Product Quick-connection cables
Details Sub cable(2-core)
Product name Cable
Cable
Product Number CN-72-C5
Part Number CN-72-C5
Product Quick-connection cables
Details Sub cable(2-core)
Product name Cable


More



Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)