AUTOMATION
CONTROLS

Search
Discontinued
Products



SF-C14EX-01 | Exclusive Control Unit for Safety Light Curtain SF-C10


Exclusive Control Unit for Safety Light Curtain SF-C10

*Photo may vary from actual product.



  • Discontinued
  • Last time buyMarch 31, 2023
Product Number SF-C14EX-01
Part Number SF-C14EX-01
Product Exclusive Control Unit for Safety Light Curtain
Details Applicantion expansion unit for the SF4B series (Handy-controller non-compatible type)
Product name Exclusive Control Unit for Safety Light Curtain SF-C10
  • Substitute -
  • Sub Prod No. -
  • Sub Part No. -
  • Remark Sorry, no suggested alternative products.

Spec Detail As of March 31, 2023

Item Specifications
Product Number SF-C14EX-01
Part Number SF-C14EX-01
Connectable safety light curtains SF4B / SF4B-G series
(Note:The handy-controller SFB-HC (optional) cannot be used with SF-C14EX-01.)
Applicable standards:International standard IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe)
CE marking directive compliance Machinery Directive, EMC Directive, RoHS Directive
Control category ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Applicable standards:Japan JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe)
Applicable standards:Europe EN 55011, EN ISO 13849-1 (Category 4, PLe)
Applicable standards:North America ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Power voltage 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Current consumption 0.2 A or less (Excluding Safety light curtain and other external connecting device)
Safety outputs(Safety output 1, Safety output 2, Safety output 3) PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)
\n<When PNP output is selected>
\n・Maximum source current: 200 mA
\n・Applied voltage: same as supply voltage
\n(between the safety output and +V)
\n・Residual voltage: 2 V or less (at 200 mA source current)\n
\n<When NPN output is selected>
\n・Maximum sink current: 200 mA
\n・Applied voltage: same as supply voltage
\n(between the safety output and 0 V)
\n・Residual voltage: 2 V or less (at 200 mA sink current)
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Operation mode(Output operation) Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)
\n Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is valid
\n OFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)
\n Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Protection circuit(Short-circuit protection) Incorporated
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Response time OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the light curtain)
ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)
(Note) The auto-reset cannot be used with safety output 3.
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4) PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)
\n<When PNP output is selected>
\n・Maximum source current: 60 mA
\n・Applied voltage: same as supply voltage
\n(between the auxiliary output and +V)
\n・Residual voltage: 2 V or less (at 60 mA source current)\n
\n<When NPN output is selected>
\n・Maximum sink current: 60 mA
\n・Applied voltage: same as supply voltage
\n(between the auxiliary output and 0 V)
\n・Residual voltage: 2 V or less (at 60 mA sink current)
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4):Operation mode(Output operation) Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is valid
\nAuxiliary output 2: ON when the override function is invalid, OFF when the override function is valid
\nAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is error
\nAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition
(Note:The auxiliary output incorporated in the SF4B series is output.)
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4):Protection circuit(Short-circuit protection) Incorporated
Muting lamp output Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Muting lamp output:Protection circuit Incorporated
PFHD 1.66 × 10-10
(Note:Probability of dangerous failure per hour)
MTTFD 100 years or more
(Note:Mean time to dangerous failure (in years))
Environmental resistance:Degree of protection Enclosure: IP40
Terminal: IP20
Environmental resistance:Ambient temperature -10 to +55 ℃ +14 to +131
\n(No dew condensation or icing allowed),
\nStorage: -25 to +70 ℃ -13 to +158 ℉
Environmental resistance:Ambient humidity 30 to 85 % RH, Storage: 30 to 95 % RH
Environmental resistance:Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Environmental resistance:Insulation resistance 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Environmental resistance:Vibration resistance 10 to 55 Hz frequency, 0.35 mm 0.014 in double amplitude in X, Y and Z directions for two hours each
Environmental resistance:Shock resistance 30 G acceleration in X, Y and Z directions three times each
Material Enclosure: ABS
Connection terminal Detachable spring-cage terminal
Weight Net weight: 250 g approx.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)