Function - Pressure sensors

機能

 

Auto-reference function

This function compensates the set threshold level for a change in the reference pressure.

Operation

(1) Normal sensing

M0 : Threshold level
P0 : Reference pressure
M0 : P0 + a

(2) With reference pressure change

If the threshold level is set with respect to a particular reference level and if this reference level changes, correct operation will not be possible.

(3) With auto-reference function

If the auto-reference input is made ON when the reference pressure changes, the threshold level M0 is corrected to a new threshold level M0', which maintains proper judgment.

M0' = P0 - α + a
  = P0' + a
Note :Take care that the data on the reference pressure value is lost when the power supply is switched off.

Application

<Air leak test>

(1) : The above graph shows a pressure curve of the air leak test.
The decision on whether the product is OK or NG is based upon whether, after reaching the peak value, the pressure reduces by 30 kPa, or more, within a fixed time interval.
(2) : The set value is input before applying pressure.
SET = -30
(3) : Apply pressure and then apply the autoreference input at time T0, when the pressure reaches the peak value. As the peak pressure is 90 kPa , the threshold level is automatically changed to 60 kPa .
SET' = -30 + 90 = 60kPa

Return to top

Remote zeroadjustment function

The remote zero-adjustment function forcibly sets the pressure value at time of application of an external input signal to zero.

Return to top

Automatic sensitivity setting function

The threshold level is automatically set by making the sensor record pressure values corresponding to actual OK and NG products.

Application

<Confirming for suction>

Return to top

Pressure unit selection function

Different pressure units can be selected.

It is possible to switch to Pa (kPa, MPa), mmHg, kgf/cm2, bar, psi, mmH2O, inHg.

Note :The pressure units that can be selected to will vary depending on the model.
Contact our office for details.

Return to top

Peak hold & bottom hold function

Peak hold and bottom hold functions enable the display of the peak value (maximum pressure value) and the bottom value (minimum pressure value) of the varying measured pressure. These functions are convenient for finding the pressure variation range or determining the reference for pressure settings.

  • Please note that the peak value and the bottom value data is erased when it is no longer displayed.
  • While the peak hold and bottom hold are displayed, there is a delay in the comparative output response time.

Return to top

Analog bar display function

Pressure changes can also be displayed in an analog fashion using LED bars. Hence, sudden pressure changes can be recognized at a glance.
LED bars indicate the pressure level in steps of 10 % F.S. (DP5 series and DP4 series are 14 % F.S.)

Analog bar of positive pressure

Analog bar of vacuum pressure

Return to top

Related Products

Download

  • pressure_e.pdfDownload

Return to top

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)