Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Microwave Devices > Microwave Devices Lineup > RA Relays > Rating/Performance
|
Rated coil voltage | Operate voltage * (at 20°C) |
Release voltage * (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power | Max. allowable voltage (at 20°C) |
---|---|---|---|---|---|---|
1.5 V DC | Max. 75% V of rated coil voltage (Initial) |
Min. 10% V of rated coil voltage (Initial) |
93.8 mA | 16 Ω | 140 mW | 150% V of rated coil voltage |
3 V DC | 46.7 mA | 64.3 Ω | ||||
4.5 V DC | 31 mA | 145 Ω | ||||
5 V DC | 28.1 mA | 178 Ω | ||||
6 V DC | 23.3 mA | 257 Ω | ||||
9 V DC | 15.5 mA | 579 Ω | ||||
12 V DC | 11.7 mA | 1,028 Ω | ||||
24 V DC | 8.3 mA | 2,880 Ω | 200 mW | |||
48 V DC | 6.3 mA | 7,680 Ω | 300 mW | 120% V of rated coil voltage |
* | Square, pulse drive |
---|
Rated coil voltage |
Set voltage* (at 20°C) |
Reset voltage* (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 20°C) |
---|---|---|---|---|---|---|
1.5 V DC | Max. 75% V of rated coil voltage (Initial) |
Max. 75% V of rated coil voltage (Initial) |
46.9 mA | 32 Ω | 70 mW | 150% V of rated coil voltage |
3 V DC | 23.3 mA | 128.6 Ω | ||||
4.5 V DC | 15.6 mA | 289.3 Ω | ||||
5 V DC | 14 mA | 357 Ω | ||||
6 V DC | 11.7 mA | 514 Ω | ||||
9 V DC | 7.8 mA | 1,157 Ω | ||||
12 V DC | 5.8 mA | 2,057 Ω | ||||
24 V DC | 4.2 mA | 5,760 Ω | 100 mW |
* | Square, pulse drive |
---|
Rated coil voltage |
Set voltage* (at 20°C) |
Reset voltage* (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 20°C) |
---|---|---|---|---|---|---|
1.5 V DC | Max. 75% V of rated coil voltage (Initial) |
Max. 75% V of rated coil voltage (Initial) |
93.8 mA | 16 Ω | 140 mW | 150% V of rated coil voltage |
3 V DC | 46.7 mA | 64.3 Ω | ||||
4.5 V DC | 31 mA | 145 Ω | ||||
5 V DC | 28.1 mA | 178 Ω | ||||
6 V DC | 23.3 mA | 257 Ω | ||||
9 V DC | 15.5 mA | 579 Ω | ||||
12 V DC | 11.7 mA | 1,028 Ω | ||||
24 V DC | 8.3 mA | 2,880 Ω | 200 mW |
* | Square, pulse drive |
---|
Item | Specifications | |
---|---|---|
Contact data | Contact arrangement | 2 Form C |
Contact resistance (initial) | Max. 75 mΩ (by voltage drop 6 V DC 1 A) | |
Contact material | Ag alloy / Au-clad Ag alloy | |
Contact rating (resistive) | 10 mA 10 V DC, 1 A 30 V DC | |
Contact input power (CW) | 3 W (1 GHz, 50 Ω, V.S.W.R. Max. 1.2) | |
Max. switching voltage | 30 V DC | |
Max. switching current | 1 A (DC) | |
Insulation resistance (initial) | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
|
Dielectric strength (initial) | Between open contacts |
750 Vrms for 1 min (detection current: 10 mA) |
Between contact and coil |
1,000 Vrms for 1 min (detection current: 10 mA) | |
Between contact sets |
1,000 Vrms for 1 min (detection current: 10 mA) | |
Between contact and earth terminal |
1,000 Vrms for 1 min (detection current: 10 mA) | |
Time characteristics (initial) | Operate (set) time | Max. 4 ms at rated coil voltage (at 20 °C, without bounce) [Max. 4 ms (at 20 °C, without bounce)] |
Release (reset) time | Max. 4 ms at rated coil voltage (at 20°C, without bounce, without diode) [Max. 4 ms (at 20 °C, without bounce)] | |
Shock resistance | Functional | 500 m/s2(half-sine shock pulse: 11 ms, detection time: 10 μs) |
Destructive | 1,000 m/s2(half-sine shock pulse: 6 ms) | |
Vibration resistance | Functional | 10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs) |
Destructive | 10 to 55 Hz (at double amplitude of 5 mm) | |
Expected life | Mechanical life (Cold switch) |
Min. 100 x 106 (switching frequency: 180 times/min) |
Conditions | Conditions for usage, transport and storage * |
Ambient temperature: -40 to +85 °C (-40 to +70 °C at our standard packing condition) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 2 g |
* | For ambient temperature, please read“GUIDELINES FOR RELAY USAGE”.. |
---|
Conditions: Resistive load, switching frequency 20 times/min
Type | Load | Switching capacity | Number of operations |
---|---|---|---|
2 Form C | Resistive load | 10 mA 10 V DC | Min. 10 x 106 |
1 A 30 V DC | Min. 100 x 103 |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)