AUTOMATION
CONTROLS

Search
Discontinued
Products



RS Relays

Coil data

  • Operating characteristics such as 'Operate voltage' and 'Release voltage' are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ±5% of rated coil voltage.
  • 'Initial' means the condition of products at the time of delivery.

1.Single side stable type

Rated coil
voltage
Operate voltage *
(at 20°C)
Release voltage *
(at 20°C)
Rated operating
current
(±10%, at 20°C)
Coil resistance
(±10%, at 20 °C)
Rated operating
power
Max. allowable
voltage
3 V DC Max. 75% V of
rated coil voltage
(Initial)
Min. 10% V of
rated coil voltage
(Initial)
66.7 mA 45 Ω 200 mW 110% V
(at 60 °C)

150% V
(at 20 °C)

of rated coil
voltage
4.5V DC 44.4 mA 101.3 Ω
9 V DC 22.2 mA 405 Ω
12 V DC 16.7 mA 720 Ω
24 V DC 8.3 mA 2,880 Ω
*square, pulse drive

2.1 coil latching type

Rated coil
voltage
Set voltage *
(at 20°C)
Reset voltage *
(at 20°C)
Rated operating
current
(±10%, at 20°C)
Coil resistance
(±10%, at 20 °C)
Rated operating
power
Max. allowable
voltage
3 V DC Max. 75% V of
rated coil voltage
(Initial)
Max. 75% V of
rated coil voltage
(Initial)
66.7 mA 45 Ω 200 mW 110% V
(at 60 °C)

150% V
(at 20 °C)

of rated coil
voltage
4.5V DC 44.4 mA 101.3 Ω
9 V DC 22.2 mA 405 Ω
12 V DC 16.7 mA 720 Ω
24 V DC 8.3 mA 2,880 Ω
*square, pulse drive

3.2 coil latching type

Rated coil
voltage
Set voltage *
(at 20°C)
Reset voltage *
(at 20°C)
Rated operating
current
(±10%, at 20°C)
Coil resistance
(±10%, at 20 °C)
Rated operating
power
Max. allowable
voltage
3 V DC Max. 75% V of
rated coil voltage
(Initial)
Max. 75% V of
rated coil voltage
(Initial)
133.3 mA 22.5 Ω 400 mW 110% V
(at 60 °C)

150% V
(at 20 °C)

of rated coil
voltage
4.5V DC 88.9 mA 50.6 Ω
9 V DC 44.4 mA 202.5 Ω
12 V DC 33.3 mA 360 Ω
24 V DC 16.7 mA 1,440 Ω
*square, pulse drive

Return to top

Specifications

Item Specifications
Contact data Contact arrangement 1 Form C
Contact resistance
(initial)
Max. 100 mΩ (by voltage drop 10 V AC 10 mA)
Contact material Au plating
Contact rating 1 W (3 GHz, 50/75 Ω, V.S.W.R.: Max. 1.4), 10 mA 24 V DC (resistive)
Contact input power (CW) Max. 10 W (3 GHz, 50/75 Ω, V.S.W.R.: Max. 1.4)
Max. switching voltage 30 V DC
Max. switching current 0.5 A (DC)
Insulation resistance (initial) Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric strength
(initial)
Between
open contacts
500 Vrms for 1 min (detection current: 10 mA)
Between
contact and coil
1,000 Vrms for 1 min (detection current: 10 mA)
Between
contact and ground
500 Vrms for 1 min (detection current: 10 mA)
Time characteristics
(initial)
Operate (Set)
time
Max. 10 ms (Max. 10 ms) at rated coil voltage (at 20°C, without bounce)
Release (Reset)
time
Max. 6 ms at rated coil voltage (at 20°C, without bounce, without diode) [Max. 10 ms (at 20°C, without bounce)]
Shock
resistance
Functional 196 m/s² (half-sine shock pulse: 11 ms, detection time: 10 μs)
Destructive 980 m/s² (half-sine shock pulse: 6 ms)
Vibration resistance Functional 10 to 55 Hz (at double amplitude of 3 mm, detection time:10 μs)
Destructive 10 to 55 Hz (at double amplitude of 5 mm)
Operation noise (initial) *1 Single side stable, Standard type: Approx. 40 dB (at 20°C)
Single side stable, Quiet type: Approx. 30 dB (at 20°C)
Latching: Approx. 40 dB (at 20°C)
Expected life Mechanical life
(Cold switch)
Single side stable, Standard type: Min. 5 x 106 (switching frequency: 180 times/min)
Single side stable, Quiet type: Min. 106 (switching frequency: 180 times/min)
Latching: Min. 106 (switching frequency: 180 times/min)
Conditions Conditions for usage,
transport and storage *2
Ambient temperature: -40 to +70 °C (Single side stable, Standard type, Latching)
(Allowable temperature is from -40 to +70 °C at our standard packing condition.)
-40 to +60 °C (Single side stable, Quiet type)
(Allowable temperature is from -40 to +60 °C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 2 g
*1Measured the operation noise of the relay alone (with diodes at both ends of the coil) 30 cm away from top side, by the A-weighted, FAST method while applying the rated voltage.
*2For ambient temperature, please read“GUIDELINES FOR RELAY USAGE”..

Return to top

Electrical life (Hot switch)

50 Ω
Conditions: Switching frequency 20 times/min

Type Load Switching capacity Number of operations
1 Form C PC board terminal Resistive load 10 mA 10 V DC Min. 106
10 mA 24 V DC Min. 300 x 103
High frequency load 1 W (3 GHz, 50 Ω, V.S.W.R.: Max. 1.4) Min. 106
Surface mount terminal Resistive load 10 mA 10 V DC Min. 300 x 103
10 mA 24 V DC Min. 300 x 103
High frequency load 1 W (3 GHz, 50 Ω, V.S.W.R.: Max. 1.4) Min. 300 x 103

75 Ω
Conditions: Switching frequency 20 times/min

Type Load Switching capacity Number of operations
1 Form C Resistive load 10 mA 24 V DC Min. 300 x 103
High frequency load 1 W (3 GHz, 75 Ω, V.S.W.R.: Max. 1.4) Min. 300 x 103

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)