AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS GU SOP 1 Form A Short Circuit Protection


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol AQY210KS Remarks
Input LED forward current IF 50mA
LED reverse voltage VR 5V
Peak forward current IFP 1A f=100Hz, Duty Ratio=0.1%
Power dissipation Pin 75mW
Output Load voltage (peak AC) VL 350V
Continuous load current IL 0.12A Peak AC, DC
Power dissipation Pout 400mW
Total power dissipation PT 450mW
I/O isolation voltage Viso 1,500Vrms
Ambient temperature (Operating) Topr -40 to +85°C (Avoid icing and condensation)
Ambient temperature (Storage) Tstg -40 to +100°C
Junction temperature Tj 125°C

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol AQY210KS Condition
Input LED operate current Typical IFon 1.1mA IL=Max.
Maximum 3.0mA
LED turn off current Minimum IFoff 0.3mA IL=Max.
Typical 1.0mA
LED dropout voltage Typical VF 1.13V (1.32V at IF=50mA) IF=5mA
Maximum 1.5V
Output On resistance Typical Ron 23.5Ω IF=5mA
IL=Max.
Within 1s
Maximum 35Ω
Off state leakage current Maximum ILeak 1μA IF=0mA
VL=350V
Over currentprotection Cut off current Minimum IShut 160mA IF=5mA
Within 20ms
Typical 200mA
Maximum 240mA
Detection time Typical TShut 50μs IF=5mA
VL=350V DC short circuit
Transfer characteristics Turn on time* Typical Ton 0.7ms IF=5mA
IL=Max.
Maximum 2ms
Turn off time* Typical Toff 0.07ms
Maximum 1ms
I/O capacitance Typical Ciso 0.8pF f=1MHz
VB=0V
Maximum 1.5pF
Initial I/O isolation resistance Minimum Riso 1,000MΩ 500V DC
*Turn on/Turn off time
Turn on/Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 5 30 mA
AQY210KS Load voltage (Peak AC) VL - 280 V
Continuous load current IL - 0.12 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)