AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS GU 2 Form A


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol AQW212(A) AQW215(A) AQW217(A) AQW210(A) AQW214(A) AQW216(A) Remarks
Input LED forward current IF 50mA
LED reverse voltage VR 5V
Peak forward current IFP 1A f=100Hz, Duty Ratio=0.1%
Power dissipation Pin 75mW
Output Load voltage (peak AC) VL 60V 100V 200V 350V 400V 600V
Continuous load current IL 0.50A
(0.60A)
0.3A
(0.35A)
0.16A
(0.2A)
0.12A
(0.14A)
0.1A
(0.13A)
0.04A
(0.05A)
Peak AC, DC
( ): in case of using only 1 channel
Peak load current Ipeak 1.5A 0.9A 0.48A 0.36A 0.3A 0.12A 100ms(1 shot), VL=DC
Power dissipation Pout 800mW
Total power dissipation PT 850mW
I/O isolation voltage Viso 1,500Vrms
Ambient temperature (Operating) Topr -40 to +85°C (Avoid icing and condensation)
Ambient temperature (Storage) Tstg -40 to +100°C
Junction temperature Tj 125°C

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol AQW212(A) AQW215(A) AQW217(A) AQW210(A) AQW214(A) AQW216(A) Condition
Input LED operate current Typical IFon 0.9mA IL=Max.
Maximum 3mA
LED turn off current Minimum IFoff 0.4mA
Typical 0.8mA
LED dropout voltage Typical VF 1.25V (1.14V at IF=5mA) IF=50mA
Maximum 1.5V
Output On resistance Typical Ron 0.83Ω 2.3Ω 11Ω 23Ω 30Ω 70Ω IF=5mA
IL=Max.
Within 1s
Maximum 2.5Ω 4.0Ω 15Ω 35Ω 50Ω 120Ω
Off state leakage current Maximum ILeak 1μA IF=0mA
VL=Max.
Transfer characteristics Turn on time* Typical Ton 0.65ms 0.60ms 0.25ms 0.31ms 0.28ms IF=5mA
IL=Max.
Maximum 2ms 1.0ms 0.5ms
Turn off time* Typical Toff 0.08ms 0.06ms 0.05ms 0.04ms
Maximum 0.2ms
I/O capacitance Typical Ciso 0.8pF f=1MHz
VB=0V
Maximum 1.5pF
Initial I/O isolation resistance Minimum Riso 1,000MΩ 500V DC
*Turn on/Turn off time
Turn on/Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Number of used channels Min. Max. Unit
LED current IF - 5 30 mA
AQW212(A) Load voltage (Peak AC) VL - - 48 V
Continuous load current IL 1ch
2ch
- 0.6
0.5
A
AQW215(A) Load voltage (Peak AC) VL - - 80 V
Continuous load current IL 1ch
2ch
- 0.35
0.3
A
AQW217(A) Load voltage (Peak AC) VL - - 160 V
Continuous load current IL 1ch
2ch
- 0.2
0.16
A
AQW210(A) Load voltage (Peak AC) VL - - 280 V
Continuous load current IL 1ch
2ch
- 0.14
0.12
A
AQW214(A) Load voltage (Peak AC) VL - - 320 V
Continuous load current IL 1ch
2ch
- 0.13
0.1
A
AQW216(A) Load voltage (Peak AC) VL - - 480 V
Continuous load current IL 1ch
2ch
- 0.05
0.04
A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)