AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS HE 1 Form A High Capacity (DIP6-pin type)


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol Type of connection AQV251G (A) AQV252G (A) Remarks
Input LED forward current
IF
- 50 mA  
LED reverse voltage
VR
- 5 V  
Peak forward current
IFP
- 1 A f=100Hz,
Duty Ratio=0.1%
Power dissipation
Pin
- 75 mW  
Output Load voltage
(peak AC)
VL
- 30 V 60 V  
Continuous load current
IL
A 3.5 A 2.5 A A connection:
Peak AC, DC
B 4.0 A 3.5 A B, C connection: DC
C 6.0 A 5.0 A
Peak load current
Ipeak
- 6.0 A A connection:
100ms (1 shot),
VL=DC
Power dissipation
Pout
- 600 mW  
Total power dissipation
PT
- 650 mW  
I/O isolation voltage
Viso
- 1,500 Vrms  
Ambient temperature
(Operating)
Topr
- -40 to +85°C (Avoid icing and condensation)
Ambient temperature
(Storage)
Tstg
- -40 to +100°C  
Junction temperature
Tj
- 125°C  

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol Type of connection AQV251G (A) AQV252G (A) Condition
Input LED operate current Typical
IFon
- 0.55 mA 0.5 mA IL=100mA
Maximum 3 mA
LED turn off current Minimum
IFoff
- 0.2 mA IL=100mA
Typical 0.45 mA
LED dropout voltage Typical
VF
- 1.14 V (1.32 V at IF= 50 mA) IF = 5 mA
Maximum 1.5 V
Output On resistance Typical
Ron
A 0.035 Ω 0.08 Ω IF = 5 mA
IL = Max.
Within 1s
Maximum 0.08 Ω 0.12 Ω
Typical
Ron
B 0.018 Ω 0.04 Ω IF = 5 mA
IL = Max.
Within 1s
Maximum 0.04 Ω 0.06 Ω
Typical
Ron
C 0.01 Ω 0.02 Ω IF = 5 mA
IL = Max.
Within 1s
Maximum 0.02 Ω 0.03 Ω
Off state leakage current Maximum
ILeak
- 1 μA IF = 0 mA
VL = Max.
Transfer characteristics Turn on time* Typical
Ton
- 1.1 ms IF = 5 mA
IL = 100 mA
VL = 10 V
Maximum 5.0 ms
Turn off time* Typical
Toff
- 0.1 ms 0.25 ms IF = 5 mA
IL = 100 mA
VL = 10 V
Maximum 0.5 ms
I/O capacitance Typical
Ciso
- 0.8 pF f = 1 MHz
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum
Riso
- 1,000 MΩ 500 V DC
Max. operating frequency Maximum
-
- 10 cps - IF = 5 mA
duty = 50%
VL x IL = 100 V・A
*Turn on/Turn off time
Turn on / Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 5 30 mA
AQV251G (A) Load voltage (Peak AC) VL - 24 V
Continuous load current (A connection) IL - 3.5 A
AQV252G (A) Load voltage (Peak AC) VL - 48 V
Continuous load current (A connection) IL - 2.5 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region