AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS HE 2 Form B


Rating

1.Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol AQW454 (A) Remarks
Input LED forward current
IF
50 mA  
LED reverse voltage
VR
5 V  
Peak forward current
IFP
1 A f = 100 Hz
Duty Ratio = 0.1%
Power dissipation
Pin
75 mW  
Output Load voltage
(peak AC)
VL
400 V  
Continuous load current
IL
0.12 A (0.16 A) A connection:
Peak AC, DC
( ): in case of using
only 1 channel
Peak load current
Ipeak
0.36 A A connection:
100 ms (1 shot)
VL = DC
Power dissipation
Pout
800 mW  
Total power dissipation
PT
850 mW  
I/O isolation voltage
Viso
1,500 Vrms  
Ambient temperature
(Operating)
Topr
-40 to +85°C (Avoid icing and condensation)
Ambient temperature
(Storage)
Tstg
-40 to +100°C  
Junction temperature
Tj
125°C  

2.Electrical characteristics (Ambient temperature: 25°C)

Item Symbol AQW454 (A) Condition
Input LED operate (OFF) current Typical
IFoff
0.9 mA IL = Max.
Maximum 3.0 mA
LED reverse (ON) current Minimum
IFon
0.4 mA IL = Max.
Typical 0.8 mA
LED dropout voltage Typical
VF
1.25 V (1.14 V at IF = 5 mA) IF = 50 mA
Maximum 1.5 V
Output On resistance Typical
Ron
11 Ω IF = 0 mA
IL = Max.
Within 1 s
Maximum 16 Ω
Off state leakage current Maximum
ILeak
1 μA IF = 5 mA
VL = Max.
Transfer characteristics Operate (OFF) time* Typical
Toff
1.2 ms IF = 0 mA → 5 mA
IL = Max.
Maximum 2.0 ms
Reverse (ON) time* Typical
Ton
0.36 ms IF = 5 mA → 0 mA
IL = Max.
Maximum 1 ms
I/O capacitance Typical
Ciso
0.8 pF f = 1 MHz
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum
Riso
1,000 MΩ 500 V DC
*Operate/Reverse time
Operate/Reverse time

3.Recommended operating conditions (Ambient temperature: 25℃)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Number of used
channels
Min. Max. Unit
LED current IF - 5 30 mA
AQW454 (A) Load voltage (Peak AC) VL - - 320 V
Continuous load current IL 1 ch
2 ch
- 0.16
0.12
A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)