AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS HS SOP 1 Form A


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol AQY232S AQY230S AQY234S Remarks
Input LED forward current IF 50 mA
LED reverse voltage VR 5 V
Peak forward current IFP 1 A f = 100 Hz
Duty Ratio = 0.1%
Power dissipation Pin 75 mW
Output Load voltage (peak AC) VL 60 V 350 V 400 V
Continuous load current IL 0.5 A 0.12 A 0.1 A Peak AC, DC
Peak load current Ipeak 1.5 A 0.3 A 0.24 A 100 ms (1 shot)
VL = DC
Power dissipation Pout 300 mW
Total power dissipation PT 350 mW
I/O isolation voltage Viso 1,500 Vrms
Ambient temperature (Operating) Topr -40 to +85°C (Avoid icing and condensation)
Ambient temperature (Storage) Tstg -40 to +100°C

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol AQY232S AQY230S AQY234S Condition
Input LED operate current Typical IFon 0.35 mA ΔIF / Δt ≥ 100 μA/s
IL= Max.
Maximum 0.5 mA
LED turn off current Minimum IFoff 0.1 mA
Typical 0.3 mA
LED dropout voltage Typical VF 1.25 V (1.1 V at IF = 2 mA) IF = 50 mA
Maximum 1.5 V
Output On resistance Typical Ron 0.85 Ω 19 Ω 27 Ω IF=2 mA
IL=Max.
Wothin 1 s
Maximum 2.5 Ω 25 Ω 35 Ω
Off state leakage current Maximum ILeak 1 μA IF = 0 mA
VL = Max.
Transfer characteristics Turn on time* Typical Ton 1.5 ms 1.2 ms 0.8 ms IF = 2 mA
IL = Max.
Maximum 5 ms
Turn off time* Typical Toff 0.15 ms 0.1 ms
Maximum 2 ms
I/O capacitance Typical Ciso 0.8 pF f = 1 MHz
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum Riso 1,000 MΩ 500 V DC
*Turn on/Turn off time
Turn on/Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 2 30 mA
AQY232S Load voltage (Peak AC) VL - 48 V
Continuous load current IL - 0.5 A
AQY230S Load voltage (Peak AC) VL - 280 V
Continuous load current IL - 0.12 A
AQY234S Load voltage (Peak AC) VL - 320 V
Continuous load current IL - 0.1 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE SEARCH FAQ

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region