AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS Power 1 Form A DC High Capacity


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol AQZ192 AQZ197 Remarks
Input LED forward current IF 50 mA
LED reverse voltage VF 5 V
Peak forward current IFP 1 A f = 100 Hz
Duty Ratio = 0.1%
Power dissipation Pin 75 mW  
Output Load voltage (DC) VL 60 V 200 V
Continuous load current (DC) IL 10 A 5 A  
Peak load current Ipeak 30 A 15 A 100 ms (1 shot)
VL = DC
Power dissipation Pout 2.0 W
Total power dissipation PT 2.0 W
I/O isolation voltage Viso 3,000 Vrms  
Ambient temperature (Operating) Topr -40 to +85°C (Avoid icing and condensation)
Ambient temperature (Storage) Tstg -40 to +100°C
Junction temperature Tj 125°C

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol AQZ192 AQZ197 Condition
Input LED operate current Typical IFon 0.7 mA IL = 100 mA
VL = 10 V
Maximum 3.0 mA
LED turn off current Minimum IFoff 0.2 mA
Typical 0.5 mA
LED dropout voltage Typical VF 1.35 V (1.17 V at IF = 10 mA) IF = 50 mA
Maximum 1.5 V
Output On resistance Typical Ron 8 mΩ 31 mΩ IF = 10 mA
IL = Max.
Within 1 s
Maximum 15 mΩ 50 mΩ
Off state leakage current Maximum ILeak 10 μA IF = 0 mA
VL = Max.
Transfer characteristics Turn on time* Typical Ton 1.0 ms 0.7 ms IF = 10 mA
IL = 100 mA
VL = 10 V
Maximum 3.0 ms
Turn off time* Typical Toff 0.11 ms 0.05 ms
Maximum 1.0 ms
I/O capacitance Typical Ciso 1.3 pF f = 1 MHz
VB = 0 V
Maximum 3.0 pF
Initial I/O isolation resistance Minimum Riso 1,000 MΩ 500 V DC
Max. operating frequency Maximum - 0.5 cps IF = 10 mA
duty = 50 %
VL = Max.
IL = Max.
*Turn on/Turn off time
Turn on/Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 10 30 mA
AQZ192 Load voltage (DC) (Peak AC) VL - 48 V
Continuous load current IL - 10 A
AQZ197 Load voltage (DC) (Peak AC) VL - 160 V
Continuous load current IL - 5 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)