■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol CxR10
Low Ron type
CxR10
Low Cout type
Remarks
AQY221R2M AQY221N2M
Input LED forward current IF 50 mA
LED reverse voltage VR 5 V
Peak forward current IFP 1 A f = 100 Hz,
Duty Ratio = 0.1%
Power dissipation Pin 75 mW
Output Load voltage (peak AC) VL 40 V
Continuous load current IL 0.25 A 0.12A Peak AC, DC
Peak load current Ipeak 0.75 A - 100 ms (1 shot),
VL = DC
Power dissipation Pout 250 mW
Total power dissipation PT 300 mW
I/O isolation voltage Viso 200 Vrms
Ambient temperature (Operating) Topr -40 to +85°C (Avoid icing and condensation)
Ambient temperature (Storage) Tstg -40 to +100°C
Junction temperature Tj 125°C

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol CxR10
Low Ron type
CxR10
Low Cout type
Condition
AQY221R2M AQY221N2M
Input LED operate current Typical IFon 0.8 mA 1.0 mA AQY221R2M:
IL = 250 mA
AQY221N2M:
IL = 80 mA
Maximum 3.0 mA
LED turn off current Minimum IFoff 0.1 mA 0.2 mA
Typical 0.7 mA 0.9 mA
LED dropout voltage Typical VF 1.14 V (1.35 V at IF 50 mA) IF = 5 mA
Maximum 1.5 V
Output On resistance Typical Ron 0.8 Ω 9.5 Ω AQY221R2M:
IF = 5 mA, IL = 250 mA
AQY221N2M:
IF = 5 mA, IL = 80 mA
Within 1 s
Maximum 1.25 Ω 12.5 Ω
Output capacitance Typical Cout 14 pF 1.1 pF IF = 0 mA
VB = 0 V
f = 1 MHz
Maximum 18 pF 1.5 pF
Off state leakage current Typical ILeak 0.02 nA 0.01 nA IF = 0 mA
VL = Max.
Maximum 10 nA*1
Transfer characteristics Turn on time*2 Typical Ton 0.2 ms 0.02 ms AQY221R2M:
IF = 5 mA, VL = 10 V,
RL = 40 Ω
AQY221N2M:
IF = 5 mA, VL = 10 V,
RL = 125 Ω
Maximum 0.5 ms 0.2 ms
Turn off time*2 Typical Toff 0.04 ms 0.02 ms
Maximum 0.2 ms
I/O capacitance Typical Ciso 0.8 pF f = 1 MHz
VB = 0 V
Maximum 1.5 pF
Note: Variation possible through combinations of output capacitance and on resistance. For more information, please contact our sales representative.

*1. Available as custom orders (1 nA or less)
*2. Turn on/Turn off time

Turn on/Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 5 30 mA
AQY221R2M Load voltage (Peak AC) VL - 15 V
Continuous load current IL - 0.25 A
AQY221N2M Load voltage (Peak AC) VL - 15 V
Continuous load current IL - 0.12 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)