AUTOMATION
CONTROLS

Search
Discontinued
Products



DJ Relays

Coil data

  • Operating characteristics such as 'Operate voltage' and 'Release voltage' are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ±5% of rated coil voltage.
  • 'Initial' means the condition of products at the time of delivery.

1.Single side stable

Rated coil voltage Operate voltage*
(at 20°C)
Release voltage*
(at 20°C)
Rated operating
current
(±10%、at 20°C)
Coil resistance
(±10%、at 20°C)
Rated operating power Max. allowable
voltage
(at 20°C)
5 V DC Max. 75% V of rated coil voltage
(Initial)
Min. 10% V of rated coil voltage
(Initial)
50 mA 100 Ω 250 mW 130%V of rated coil voltage
6 V DC 41.7 mA 144 Ω
12 V DC 20.8 mA 576 Ω
24 V DC 10.4 mA 2,304 Ω
48 V DC 5.2 mA 9,216 Ω
*square, pulse drive

2.1 coil latching

Rated coil voltage Set voltage*
(at 20°C)
Reset voltage*
(at 20°C)
Rated operating
current
(±10%、at 20°C)
Coil resistance
(±10%、at 20°C)
Rated operating power Max. allowable
voltage
(at 20°C)
Set
coil
Reset
coil
Set
coil
Reset
coil
5 V DC Max. 70% V of rated coil voltage
(Initial)
Max. 70% V of rated coil voltage
(Initial)
29.9 mA 29.9 mA 167 Ω 167 Ω 150 mW 130% V of rated coil voltage
6 V DC 25 mA 25 mA 240 Ω 240 Ω
12 V DC 12.5 mA 12.5 mA 960 Ω 960 Ω
24 V DC 6.3 mA 6.3 mA 3,840 Ω 3,840 Ω
48 V DC 3.1 mA 3.1 mA 15,360 Ω 15,360 Ω
*square, pulse drive

3.2 coil latching

Rated coil voltage Set voltage*
(at 20°C)
Reset voltage*
(at 20°C)
Rated operating
current
(±10%、at 20°C)
Coil resistance
(±10%、at 20°C)
Rated operating power Max. allowable
voltage
(at 20°C)
Set
coil
Reset
coil
Set
coil
Reset
coil
5 V DC Max. 70% V of rated coil voltage
(Initial)
Max. 70% V of rated coil voltage
(Initial)
50 mA 50 mA 100 Ω 100 Ω 250 mW 130% V of rated coil voltage
6 V DC 41.7 mA 41.7 mA 144 Ω 144 Ω
12 V DC 20.8 mA 20.8 mA 576 Ω 576 Ω
24 V DC 10.4 mA 10.4 mA 2,304 Ω 2,304 Ω
48 V DC 5.2 mA 5.2 mA 9,216 Ω 9,216 Ω
*square, pulse drive

Return to top

Specifications

Item Specifications
Contact data Contact arrangement 1 Form C, 1 Form A, 1 Form B 1 Form A 1 Form B
2 Form C, 2 Form A, 2 Form B
Contact resistance (initial) Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact material AgSnO2 type Au-flashed AgSnO2 type
Contact rating (resistive) 16 A 250 V AC 10 A 250 V AC
Max. switching power (resistive) 4,000 VA 2,500 VA
Max. switching voltage 250 V AC
Max. switching current 16 A (AC) 10 A (AC)
Min. switching load (reference value)* 100 mA 5 V DC
Insulation resistance (initial) Min. 1,000 MΩ
(at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric
strength
(initial)
Between
open contacts
1,000 Vrms for 1 min (detection current: 10 mA)
Between
contact sets
- 2,000 Vrms for 1 min
(detection current: 10 mA)
Between
contact and coil
4,000 Vrms for 1 min (detection current: 10 mA)
Surge
withstand
voltage
(initial)*2
Between
contact and coil
10,000 V
Time
characteristics
(initial)
Operate (Set) time Max. 20 ms (Max. 20 ms) at rated coil voltage (at 20°C, without bounce)
Release (Reset) time Max. 20 ms (Max. 20 ms) at rated coil voltage (at 20°C, without bounce, without diode)
Shock
resistance
Functional 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Destructive 1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration resistance Functional 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
Destructive 10 to 55 Hz (at double amplitude of 3 mm)
Expected life Mechanical life Min. 5 x 106 ope. (switching frequency: at 180 times/min)
Conditions Conditions for usage,
transport and storage
*3
Ambient temperature: -40 to +70°C
Humidity:5 to 85% RH
(Avoid icing and condensation)
Unit weight Approx. 14 g
*1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2Wave is standard shock voltage of ±1.2 x 50 μs according to JEC-212-1981
*3For ambient temperature, please read “GUIDELINES FOR RELAY USAGE”.

Return to top

Expected electrical life

Conditions: Resistive load, switching frequency 20 times/min

Type Switching capacity Number of operations
1 Form C, 1 Form A, 1 Form B 16 A 250 V AC Min. 100 x 103 ope.
1 Form A 1 Form B, 2 Form C, 2 Form A, 2 Form B 10 A 250 V AC Min. 100 x 103 ope.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)