Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > Power Relays (Over 2A) Lineup > DJ Relays > Rating/Performance
|
Rated coil voltage | Operate voltage* (at 20°C) |
Release voltage* (at 20°C) |
Rated operating current (±10%、at 20°C) |
Coil resistance (±10%、at 20°C) |
Rated operating power | Max. allowable voltage (at 20°C) |
---|---|---|---|---|---|---|
5 V DC | Max. 75% V of rated coil voltage (Initial) |
Min. 10% V of rated coil voltage (Initial) |
50 mA | 100 Ω | 250 mW | 130%V of rated coil voltage |
6 V DC | 41.7 mA | 144 Ω | ||||
12 V DC | 20.8 mA | 576 Ω | ||||
24 V DC | 10.4 mA | 2,304 Ω | ||||
48 V DC | 5.2 mA | 9,216 Ω |
* | square, pulse drive |
---|
Rated coil voltage | Set voltage* (at 20°C) |
Reset voltage* (at 20°C) |
Rated operating current (±10%、at 20°C) |
Coil resistance (±10%、at 20°C) |
Rated operating power | Max. allowable voltage (at 20°C) |
||
---|---|---|---|---|---|---|---|---|
Set coil |
Reset coil |
Set coil |
Reset coil |
|||||
5 V DC | Max. 70% V of rated coil voltage (Initial) |
Max. 70% V of rated coil voltage (Initial) |
29.9 mA | 29.9 mA | 167 Ω | 167 Ω | 150 mW | 130% V of rated coil voltage |
6 V DC | 25 mA | 25 mA | 240 Ω | 240 Ω | ||||
12 V DC | 12.5 mA | 12.5 mA | 960 Ω | 960 Ω | ||||
24 V DC | 6.3 mA | 6.3 mA | 3,840 Ω | 3,840 Ω | ||||
48 V DC | 3.1 mA | 3.1 mA | 15,360 Ω | 15,360 Ω |
* | square, pulse drive |
---|
Rated coil voltage | Set voltage* (at 20°C) |
Reset voltage* (at 20°C) |
Rated operating current (±10%、at 20°C) |
Coil resistance (±10%、at 20°C) |
Rated operating power | Max. allowable voltage (at 20°C) |
||
---|---|---|---|---|---|---|---|---|
Set coil |
Reset coil |
Set coil |
Reset coil |
|||||
5 V DC | Max. 70% V of rated coil voltage (Initial) |
Max. 70% V of rated coil voltage (Initial) |
50 mA | 50 mA | 100 Ω | 100 Ω | 250 mW | 130% V of rated coil voltage |
6 V DC | 41.7 mA | 41.7 mA | 144 Ω | 144 Ω | ||||
12 V DC | 20.8 mA | 20.8 mA | 576 Ω | 576 Ω | ||||
24 V DC | 10.4 mA | 10.4 mA | 2,304 Ω | 2,304 Ω | ||||
48 V DC | 5.2 mA | 5.2 mA | 9,216 Ω | 9,216 Ω |
* | square, pulse drive |
---|
Item | Specifications | ||
---|---|---|---|
Contact data | Contact arrangement | 1 Form C, 1 Form A, 1 Form B | 1 Form A 1 Form B 2 Form C, 2 Form A, 2 Form B |
Contact resistance (initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | ||
Contact material | AgSnO2 type | Au-flashed AgSnO2 type | |
Contact rating (resistive) | 16 A 250 V AC | 10 A 250 V AC | |
Max. switching power (resistive) | 4,000 VA | 2,500 VA | |
Max. switching voltage | 250 V AC | ||
Max. switching current | 16 A (AC) | 10 A (AC) | |
Min. switching load (reference value)* | 100 mA 5 V DC | ||
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
||
Dielectric strength (initial) |
Between open contacts |
1,000 Vrms for 1 min (detection current: 10 mA) | |
Between contact sets |
- | 2,000 Vrms for 1 min (detection current: 10 mA) |
|
Between contact and coil |
4,000 Vrms for 1 min (detection current: 10 mA) | ||
Surge withstand voltage (initial)*2 |
Between contact and coil |
10,000 V | |
Time characteristics (initial) |
Operate (Set) time | Max. 20 ms (Max. 20 ms) at rated coil voltage (at 20°C, without bounce) | |
Release (Reset) time | Max. 20 ms (Max. 20 ms) at rated coil voltage (at 20°C, without bounce, without diode) | ||
Shock resistance |
Functional | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) | |
Destructive | 1,000 m/s2 (half-sine shock pulse: 6 ms) | ||
Vibration resistance | Functional | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs) | |
Destructive | 10 to 55 Hz (at double amplitude of 3 mm) | ||
Expected life | Mechanical life | Min. 5 x 106 ope. (switching frequency: at 180 times/min) | |
Conditions | Conditions for usage, transport and storage *3 |
Ambient temperature: -40 to +70°C Humidity:5 to 85% RH (Avoid icing and condensation) |
|
Unit weight | Approx. 14 g |
*1 | This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. |
---|---|
*2 | Wave is standard shock voltage of ±1.2 x 50 μs according to JEC-212-1981 |
*3 | For ambient temperature, please read “GUIDELINES FOR RELAY USAGE”. |
Conditions: Resistive load, switching frequency 20 times/min
Type | Switching capacity | Number of operations |
---|---|---|
1 Form C, 1 Form A, 1 Form B | 16 A 250 V AC | Min. 100 x 103 ope. |
1 Form A 1 Form B, 2 Form C, 2 Form A, 2 Form B | 10 A 250 V AC | Min. 100 x 103 ope. |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)